1 / 1
Model No. : | SL-300-12 |
---|
Product description
Model | SL-300-5 | SL-300-12 | SL-300-18 | SL-300-24 | SL-300-36 | SL-300-48 |
|
||
Output | DC voltage | 5V | 12V | 18V | 24V | 36V | 48V | 60V | |
Rated power | 60A | 25A | 16.5A | 12.5A | 8.3A | 6.25A | 5A | ||
Current range | 0-72A | 0-30A | 0--20A | 0-15A | 0--10A | 0--7.5A | 0--6A | ||
Power | 300W | 300W | 300W | 300W | 300W | 300W | 300W | ||
Ripple & Noise (max.) | 85mVp-p | 130mVp-p | 130mvp-p | 140mVp-p | 140mVp-p | 150mVp-p | 150mVp-p | ||
Voltage ADJ.range V | 4.2--6.3 | 9.5--14.6 | 15.8--21.4 | 21.2--26.5 | 30.5--40 | 42.5--52.5 | 55--64 | ||
Setup, Rise Time, Hold up time (Typ.) | 200ms,40ms,30ms/230VAC. | ||||||||
Input | Voltage range | 95VAC--265VAC(By switch) 47~63Hz,upper bound 300VAC | |||||||
AC curren | 6A/115V 4A/230VAC | ||||||||
Efficiency | 78% | 78% | 80% | 80% | 82% | 83% | 85% | ||
Inrush current | CCA,coolstartcurrent 20A/230VAC 40A/115VAC | ||||||||
Leakage current | <3.5mA/230VAC -115VAC | ||||||||
Protection | Overload | Rated output power 115%~135% | |||||||
Shut down o/p voltage, re-power on to recover | |||||||||
Over voltage | 135% | 120% | 120% | 115% | 120% | 110% | 110% | ||
automatic recovery after fault condition is removed to restore | |||||||||
Over temperature | RTH≥50°C Fan ON RTH≤50°C Fan OFF | ||||||||
85°fan mandatory cooling | |||||||||
Environment | Working temperature, humidity | -20degrees~+65degrees;20%~90%RH | |||||||
Storage temperature, humidity | -20degrees~+85degrees;10%~95%RH non=condensing | ||||||||
Safety | Withstand voltage | 0.5KVAC :1.5KVAC output:1.5KVAC | |||||||
Insulation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | ||||||||
Compliance Standard | Safety standard | Compliance UL1012 | |||||||
EMC Standard | Compliance EN55022,CLASSA | ||||||||
Others | Package | ||||||||
Dimension | |||||||||
Remarks | 1. All parameters are measured at 230VAC input, rated load and under 25 degrees, unless specified. | ||||||||
2. Ripple and noise voltage is at 20MHz of bandwidth 12 inches twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. . | |||||||||
3. Tolerance: includes set up tolerance, line regulation and load regulation . |
Send your inquiry to this supplier