Specifications
1.Internal DC STWTICH
2.Compact Design
3.MPPT control
4.MTL-String
General Descriptions
> Maximum efficiency of 97.8 % and wide input voltage range
> Transformerless H6 topology
> Comprehensive OUYAD warranty program
> Easy country configuration, easy installation
> Multi-language display
Safety
> Full protection functions:DC reverse polarity, AC short-circuit protection, ground fault monitoring, grid monitoring, integrate all-pole sensitive, leakage current monitoring unit.
Standards complied: EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4,EN61000-3-2, EN50178, VDE0126-1-1,IEC-62109
Technical Specifications
Model |
NB-10000TL |
Input data(DC) |
|
Max. DC power |
10500W |
Max. DC voltage |
1000V |
Start Voltage |
350V |
PV voltage range |
180V-1000V |
MPP voltage range/
nominal voltage |
300V-1000V/600V |
Full load DC voltage range |
400V-800V |
Max. input current |
15A/15A |
Max. input current per string |
20A |
Number of independent MPP trackers/strings per MPP tracker |
2/2 |
Output (AC) |
|
Rated AC output power |
10KW |
Max AC apparent power |
10KVA |
Max. output current |
16A |
AC nominal voltage; range |
3/N/PE, 230V/400V 184~275V |
AC grid frequency; range |
50/60Hz 44-55Hz/54-65Hz |
Power factor |
0.8leading - 0.8laging |
THD |
<3% |
AC grid connection type |
Three phase |
Efficiency |
|
Max efficiency |
98% |
Euro-eta |
97.5% |
MPPT efficiency |
99.5% |
General Data |
|
Dimensions(W/H/D) |
740/440/235 mm
29.1/17.3/9.3 inch |
Weight |
41kg/90.4lb |
Operating temperature range |
-25 °C ... +60 °C
(-13 °F ... +140 °F)
With derating above 45 °C(113 °F) |
Noise emission (typical) |
≤ 55 dB(A) |
Self-consumption night |
<0.5 W |
Topology |
transformerless |
Cooling concept |
Smart cooling |
Environmental Protection Rating |
IP65 |
Relative humidity |
0...95%
Non-condensing |
Display |
LCD |
Warranty
To provide better service to OYD's end users, all OYD-tech's authorized
distributors are requested to respond to end users' warranty claim, and the
authorized distributors will replace any products or parts of the product during the warranty period proved to be defective in design or manufacture. The following cases will be excluded from the warranty (the Distributors are liable for
investigation of the following):
1)"Warranty Card" not being sent back to distributor or OYD-tech.
2) Product modified or design changed or parts replaced not approved by
OYD-tech.
3) Modifications, changes, or attempted repairs and erase series
number or seals by non OYD-tech's technician.
4) Incorrect installation or commissioning
5) Failure to observe the applicable safety regulations (AS4777 standards, etc.)
6) The Product has been improperly stored and damaged while being stored by
the end user.
7) Transport damage, Painting scratch caused by shipping pumping. It should
declare to insurance company as soon as containers unload with enough
evidence.
8) Failure to observe the user manual, the installation guide, and the
maintenance regulations
9) Incorrect use or inappropriate operation
10) Insufficient ventilation of the device
Warnings
- No dismantling without authorization
- Please install inverter in the low humidity and well-ventilated place to avoid the overheating, and clear around the inflammable and explosive materials.
- Use the inverter out of children's reaching place to avoid electric shock.
- Connect the AC terminal to AC power socket.
- Connect the DC terminal to solar panel or battery