0.56 inch Mini Digital Voltmeter Ammeter DC 100V 10A Panel Amp Volt Voltage Current Meter Tester Blue Red Dual LED Display
0.56 inch Mini Digital Voltmeter Ammeter DC 100V 10A Panel Amp Volt Voltage Current Meter Tester Blue Red Dual LED Display
0.56 inch Mini Digital Voltmeter Ammeter DC 100V 10A Panel Amp Volt Voltage Current Meter Tester Blue Red Dual LED Display
0.56 inch Mini Digital Voltmeter Ammeter DC 100V 10A Panel Amp Volt Voltage Current Meter Tester Blue Red Dual LED Display
0.56 inch Mini Digital Voltmeter Ammeter DC 100V 10A Panel Amp Volt Voltage Current Meter Tester Blue Red Dual LED Display
0.56 inch Mini Digital Voltmeter Ammeter DC 100V 10A Panel Amp Volt Voltage Current Meter Tester Blue Red Dual LED Display
0.56 inch Mini Digital Voltmeter Ammeter DC 100V 10A Panel Amp Volt Voltage Current Meter Tester Blue Red Dual LED Display
0.56 inch Mini Digital Voltmeter Ammeter DC 100V 10A Panel Amp Volt Voltage Current Meter Tester Blue Red Dual LED Display

Video

1 / 6

0.56 inch Mini Digital Voltmeter Ammeter DC 100V 10A Panel Amp Volt Voltage Current Meter Tester Blue Red Dual LED Display

  • $0.02

    ≥5 Pieces

  • $0.02

    ≥10 Pieces

  • $0.02

    ≥20 Pieces

  • $0.02

    ≥50 Pieces

Options:

  • 48x29x22mm
Send Inquiry
Start Order
Model No. :
Brand Name : Roarkit
Brand Name : Roarkit
Origin : Cn(Origin)
DIY Supplies : Electrical
Display Type : Digital Only
Dimensions : 48*29*22mm
Power Supply : Dc
Operating Temperature : -10-+65
Accuracy Class : High
Model Number : Digital Voltmeter Ammeter Dc 100v 10a
More
3yrs

Ningbo, Zhejiang, China

Visit The Store

Product description

 

Matching DIY Suite Shopping Link:

Working voltage of Meter itself: The maximum input voltage can not exceed 30V. Otherwise the meter will be burned Display color: 5 colors Display: 0.28" LED digital. Operating voltage: DC 4.5 ~ 30V. Measure voltage: DC 0 ~ 100V. Minimum resolution (V): 0.1V. Refresh rate: ≥500ms / times. Measure accuracy: 1% (± 1 digit). Minimum resolution (A): 0.01A. Operating Current: <20mA. Measure current: 10A (direct measurement, built-in shunt). Operating temperature: -10 to 65°c. Operating Humidity: 10 to 80% (non-condensing).

Why there are individual customers bad evaluation is not easy to use! Many aspects of the customer themselves did not notice these matters! Many customers beyond the 30V no external power supply directly, resulting in product burned,( 58912878,and then repeat the side, we factory 100% test) according to the customer often have a variety of questions to make the following summary reference: Note: the range of 50A or 100A of the table regardless of whether the measured current is less than 10A must be connected to the shunt to measure the current! Otherwise it will burn the head. The voltage display is normal and the current display is 0.00 or 0.0 Make sure that the thick black line is receiving the negative pole of the battery and the thick red wire is connected to the negative pole of the load. (Note that the discharge is not the same as the wiring of the charge, see the final concept of load and power). (The use of original imported chip head, the factory after a very rigorous testing and calibration to ensure that no quality problems before leaving the factory. Encountered current display 0 99.99% of the wiring is wrong, please patiently carefully check the wiring) Current display is not allowed If it is a direct power supply or independent power supply with the device power is a common ground, as long as the black line can be broken off precision. Connected to the power supply is not displayed Any AC power through the rectifier must be connected to a 1000uF electrolytic capacitor filter before the power supply to the meter. Judge the header is good or bad (the following is the normal case of the two cases) Not connected to the shunt, then fine red line and thin black line to the power supply, the range of 50A of the table current display 50.0 ~ 59.9, range of 100A of the table shows 100 to 109; Connected to the shunt, then fine red line and thin black line to the power supply, the range of 50A meter current display 0.00, the range of 100A of the table shows 0.0; Other precautions The current can only be measured in the negative side of the power supply and the negative load. Voltage range: 5 lines of the table power supply voltage range is 4 ~ 28V, that is, fine red line then the voltage can not exceed 28V. On the concept of load and power Discharge: battery, switching power supply, transformer is the power supply, resistance, light, motor, power equipment is the load. Charging: Charger, generator, solar energy is the power, rechargeable battery, battery is the load.

Video

Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628