Thoracic surgery sternum saw attanchment
Thoracic surgery sternum saw attanchment
Thoracic surgery sternum saw attanchment

1 / 1

Thoracic surgery sternum saw attanchment

Get Latest Price
Send Inquiry
Model No. : BJ2106
Brand Name : Bojin

Product description

Specifications Thoracic surgery sternum saw attanchment

1. Handpiece can drive a variety quick connects.

2. Assembled and disassembled easily

Thoracic surgery sternum saw attanchment     Application: Thoracic surgery sternum saw attanchment For application in thoracic surgery. With the perfect shape of ergonomic design,whole unit is autoclavable,motor is imported,low noise, steadily and quickly cutting,no damage for soft tissue,long service life,be warranty for 1 year.   Specification: Thoracic surgery sternum saw attanchment

Output power

≥90w

Speed(r.p.m) 

/

Oscillations (osc/min) 

0-15000

Torque(Nm)

/

Operation(V) voltage

14.4

Sterilization

135°C

Swings (°) 

/

Noise(db) 

≤70

  Warranty: Thoracic surgery sternum saw attanchment The handpiece guarantees for one year, the battery and other fast consumption items guarantee for 3 months. Advantages: 1.Our whole power tool can be autoclavable. 2.We can autoclavable for 135 °C (Improved type ≤ 155 °C ),with 1.6Mpa,in this way the bacilli and virus which can not killed by the suffocating will be killed. 3.We use environment friendly nickel-metal hydride battery. 4.The machine has very low noise. 5.Our products has 1 year warranty period.   Notes: Thoracic surgery sternum saw attanchment 1.Sterilize temperature ≤ 135 °C (Improved type ≤ 155 °C ),if the temperature is over 135 °C, the motor will be damaged. 2.Normal bone drill can only hold drill bits less than 6mm,acetabulum reaming drill with big torque,rpm is around 300,canulate drill is used with nail or K wire ,rpm is around 600. 3.The battery need to be get out of the pwer tool after surgery.Otherwise the small automatic discharge of the electric will make the life of the battery short. 4.The battery cannot be sterilized ,it is not autoclavable. 5.The cranial bur must be washed right after the surgery by purger in order to aviodthe blood stick in the bur,then we should make it dry. 6.The battery space in the handpiece of the tool should not have any water,after sterilization. 7.The cranial bur blade is made of medical stainless steel,in order to avoid broken,so it is flexible and not very hard,it is easy to be attrite,we suggest each blade only use for 1 surgery.   Thoracic surgery sternum saw attanchment          Thoracic surgery sternum saw attanchment
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628