1 / 4
Model No. : | TG5 |
---|---|
Brand Name : | TENGEN/OEM |
Wenzhou, Zhejiang, China
Product description
Surge Protection Device With Removable Protector Unit
1.Application:
Expensive electronic equipment is being increasingly used in all kinds of business, industry, government and enterprise anddomestic households. Electronic discharge, over voltage cause by switching or by lightning often cause these highly sensitiveunits to fail.
Electronic equipment is especially prone up to 1.5km way from lightning strikes due to the electromagnetic fields and cable-bome over voltages. However, effective protection is now available.
Over voltage protective devices for TN-S,TN-C,TN-C-S,TT and IT power systems and plants are subdivided into Classes A,B,Cand D depending on their application area, accordingly to DIN VDE 0675-6 (11.89). Compex offers over voltage protective devicesfor Classes B to D, witch cover the complete installation on the low volage side.
Comply with:IEC 61643
2.Feature:Type | BY1-B/4-385-30 | BY -40 |
---|---|---|
Class | B | B |
Rated voltage Un(V) | 220/380 | 220/380 |
Maximum continuous operating voltage Us (V) | 385 | 385 |
Protection level Up(KV) | ≤2.0 | ≤2.0 |
Nominal discharge current (8/20uS) In (KA) | 30 | 40 |
Max discharge current (8/20uS) Imax (KA) | 60 | 80 |
Response time T (ns) | <25 | <25 |
Temperature range | -40oC +80oC | -40oC~ +80oC |
Color (module/base) | Orange red/gray | Orange red/gray |
Material | PBT | PBT |
Back up fuse | 63A gl | 63A gl |
With alarm model | BY1-B/4-385-30B | BY1-B/4-385-40B |
With remote control contact model | BY1-B/4-385-30X | BY1-B/4-385-40X |
Type | BY2-30 | BY2-60 |
---|---|---|
Test class | I | I |
class | B | B |
Rated voltage Un (V) | 220/380 | 220/380 |
Max continuous operating voltage Uc (V) | 420 | 420 |
Insulated resistance Riso ( Ω) | ≥1010 | ≥1010 |
Protection level Up (KV) | ≤4.0 | ≤4.0 |
Nominal DC spark voltage Un (KA) | 2.95KV (+25%/-40% ) | 2.95KV (+25%/-40% ) |
Nominal discharge current (8/20uS) In (KA) | 30 | 60 |
Charge Q (As) | 15 | 30 |
Power W/R (KJ/Ω) | 225 | 900 |
Response time T (ns) | <100 | <100 |
Air humidity | ≤95% | ≤95% |
Temperature range | -40oC~ +80oC | -40oC~ +80oC |
Protection grade | IP20 | IP20 |
Max back up fuse | 205A gl | 205A gl |
Model | BY4-60 | BY4-80 | BY4-100 |
---|---|---|---|
Test to | IEC61643-1 | IEC61643-1 | IEC61643-1 |
class | B | B | B |
Rated voltage Un (V) | 220/380 | 220/380 | 220/380 |
Max continuous operating voltage Uc (V) | 385 | 385 | 385 |
Shock current limp (10/35uS) (KA) | 7.5 | 12 | 15 |
Charge Q (As) | 2.5 | 3.75 | 5 |
Protection level Up (KV) | ≤2.0 | ≤2.5 | ≤3.0 |
Maximum discharge current Imax (8/20uS) (KA) | 60 | 80 | 100 |
Nominal discharge current (8/20uS) In (KA) | 30 | 40 | 60 |
Response time T (ns) | <25 | <25 | <25 |
Color (module/base) | Orange red/gray | Orange red/gray | Orange red/gray |
Temperature range | -40oC~ +80oC | -40oC~ +80oC | -40oC~ +80oC |
Protection grade | IP20 | IP20 | IP20 |
Max back up fuse | 63~100A gl | 63~100A gl | 63~100A gl |
Type | BY1-C | |||||
---|---|---|---|---|---|---|
Class | C | |||||
Rated voltage Un (V) | 110 | 220/380 | ||||
Max continuous operating voltage Uc (V) | 140 | 275 | 320 | 385 | 420 | 550 |
Protection level Up (KV) | ≤0.8 | ≤1 | ≤1.5 | ≤2.0 | ≤2.5 | |
Max discharge current Imax (8/20uS) (KA) | 40 | |||||
Nominal discharge current (8/20uS) In (KA) | 20 | |||||
Response time T (ns) | <25 | |||||
Temperature range | -40oC~ +80oC | |||||
Material | PBT | |||||
Color (module/ base) | Grey/gray | |||||
Max back up fuse | 32A gl | |||||
Normal model | BY1-C/4-420-20,BY1-C/4-385-20 | |||||
With alarm model | BY1-C/4-420-20B | |||||
With remote control contact model | BY1-C/4-420-20X | |||||
Single phase 2P combined to single phase system | BY1-C/2-320-20 |
Type | BY1-C/3+1-320-20 | BY1-C/2+1-320-20 | |||
---|---|---|---|---|---|
Test to | IEC61643-1 | IEC61643-1 | |||
class | C | C | |||
Rated voltage Un (V) | 380 | 220 | |||
Max continuous operating voltage Uc (V) | 320 | 385 | 420 | 550 | 320 |
Protection level Up (KV) | ≤1.5 | ≤2.0 | ≤2.0 | ≤2.5 | ≤1.5 |
Max continuous operating current (A) | 300 | 20 | |||
Nominal discharge current (8/20uS) In (KA) | N-PE20 N-PE40 | 20 | |||
Response time T (ns) | <100 | <100 | |||
Color (module/N-PE) | Gray/blue | Gray/blue | |||
Protection grade | IP20 | IP20 | |||
Max back up fuse | 32A gl | 32A gl |
Type | BY1-D/2 | BY1-D/4 |
---|---|---|
Class | D | D |
Rated voltage Un (V) | 220 | 380 |
Max continuous operating voltage Uc (V) | 320 | 220 |
Protection level Up (KV) | ≤1.0 | ≤1.0 |
Max discharge current Imax (8/20uS) (KA) | 10 | 10 |
Nominal discharge current (8/20uS) In (KA) | 5 | 5 |
Response time T (ns) | <25 | <25 |
Temperature range | -40oC~+80oC | -40oC~+80oC |
Max back up fuse | 16A gl | 16A gl |
Material | PBT | PBT |
Color (module/base) | Yellow/gray | Yellow/gray |
Normal model | BY1-D/2-320 | BY1-D/4-320 |
With alarm model | BY1-D/2-320B | BY1-D/4-320B |
With remote control contact model | BY1-D/2-320X | BY1-D/4-320X |
Type | BY3-2.5/150 | BY3-4.0/320 | BY3-6.0/420 |
---|---|---|---|
Class | D | D | D |
Rated voltage Un (V) | 110 | 220 | 220 |
Max continuous operating voltage Uc (V) | 150 | 320 | 420 |
Insulated resistance risol (M Ω) | >100 | >100 | >100 |
Protection level Up (KV) | ≤0.8 | ≤1.0 | ≤1.5 |
Max discharge current Imax (8/20uS) (KA) | 10 | 10 | 0 |
Nominal discharge current (8/20uS) In (KA) | 5 | 5 | 5 |
Response time T (ns) | <100 | <100 | <100 |
Open voltage (1.2/50uS) Uoc (kV) | 2.5 | 4.0 | 6.0 |
Temperature range | -40oC~ +80oC | -40oC~ +80oC | -40oC~ +80oC |
Protection grade | IP20 | IP20 | IP20 |
Color | Yellow | Yellow | Yellow |
Material | PBT | PBT | PBT |
Wenzhou, Zhejiang, China
Send your inquiry to this supplier