PWA- IV type ammonia nitrogen online analyzer
PWA- IV type ammonia nitrogen online analyzer
PWA- IV type ammonia nitrogen online analyzer

1 / 1

PWA- IV type ammonia nitrogen online analyzer

Get Latest Price
Send Inquiry
Model No. : PWA-IV
Brand Name : PCAI

Product description

Specifications ammonia nitrogen online analyzer

Power supply: 220 v. AC, 50 Hz

Sampling water pump: flow: 3-5 m/h

Head: 6.5 m

Power: 0.5

PWA- IV type ammonia nitrogen online analyzer Summarize PWA –IV- type precision preprocessor combines a sample acquisition and preprocessing functions in one of the preprocessor. For ammonia nitrogen, fluorine ion, copper ion and soluble component online analysis to provide samples, Preprocessor with reverse separation sampling technology, precision filtration technology and micro pump and water mixed self-cleaning line technology. Preprocessor from industrial controller control, can realize and analyzer and system communication linkage and remote control, long-term reliable operation, the operation is simple, unattended.  Principle The analyzer host control external water pump mining water, water sample after reverse separation sampling technology to the large water and sediment particle filter sediment, then after filtration precision for 1-5 um precision filter to remove tiny particles, and finally a clean water stored up in overflow sampling dish for analyzer sampling. Tap water after pressure reducing valve, solenoid valve control, used to finish line self-cleaning; Micro pump for precision filter for blowback cleaning, ensure sampler and filter unit long-term use, reduce the quantity of equipment maintenance. Reverse separation sampling technique Precision filtration technology            Micro pump and water cleaning counter blowing technology Analyzer and host direct control and instrument linkage, communication, remote control  Application fields  PWA  type IV preprocessor is for sewage detection and design of the sample pretreatment equipment. Suitable for soluble ingredient analysis of wastewater pretreatment process, also can be used for industrial, surface water and other fields.  Technical indexes  Power supply: 220 v. AC, 50 Hz  Sampling water pump: flow: 3-5 m/h  Head: 6.5 m  Power: 0.55 kw (typical reference data)  Filtration precision: 1-500 um (optional filter membrane)  Sample flow: 50-1000 ml/min (control)  Micro pump: 24 v. DC, 0.08 MP a, 6 l/min  The environment temperature: 5-45 degrees Celsius  Environmental humidity: 10-90%  Physical size: 900 mm (W) * 600 mm (D) * 450 mm (H)  Weight: 30 kg  Pipe connection  Water sample line: 20 mm * 15 mm (outside diameter * inside), material for U - PVC or ABS.  Tap water line: 20 mm * 15 mm (outside diameter * inside), material for U - PVC or ABS.  Drain road: 20 mm * 15 mm (outside diameter * inside), material for U - PVC or ABS.  Reverse blowpipe road: 6 mm * 4 mm (outside diameter * inside), material for silicone hose.  Connection ways: by make articulated   

Project

Parameters Standard

Measurement methods

Ammonia gas electrode

Test range

(0-10) mg/l, (10-100) mg/l, (100-1000) mg/l (1000-10000) mg/l 4 gears range optional 

Detected assembly line

0.05 mg/l 

Resolution

<0.01mg/l

Accuracy

Standard solution < 10%; Water sample < 15%

Reproduce Degree

<5%

Periodic measurement

 

Fast measurement < 3 minutes, accurate measurement < 15 minutes 

Uptime

≥720h/time

Span drift

±5%F.S

Do sample interval

Continuous, 1 hour, two hours... 24 hours, trigger 

Calibration interval

Manually or by the selected interval and time automatic (1-7 days) 

Cleaning interval

Manually or by the selected interval and time automatic (1-7 days) 

Maintenance interval

> 1 month, every time about 1 hour 

Reagent consumption

Each reagent about 358 sample

Man-machine interface

7 inches, 70000 color, 800 * 480 resolution, TFT truecolor touch screen

Print

Reserve printer interface, but external industrial miniature printer (optional)

Storage

Article 20000 data, no lose when power supply drop, is filled with automatic covering the earliest data (can match article 40000 increase data) 

Communication interface

1 road RS232 digital interface or RS485, support MODBUS protocol or custom agreement 

1 road analog 4-20 ma (20 ma corresponding range adjustable)

Pretreatment system

Self-cleaning, counter blowing, precision filter function, ensure that the sample has good representative at the same time, also avoid the suspended particle plugging line (optional) 

                               Product Specifications                             

Dimensions

900*600*450(mm)

Weight

50kg

Power supply

AC220V±20%,50HZ±1%

Power

300w

Ambient temperature

5~40ºC

Humidity

≤85%

  Widely applied to ammonia nitrogen concentration monitoring on floss hole of pollution source, municipal wastewater, industrial sewage, commercial running water, rivers, lakes, reservoirs and tap Water pipe-network, served for Environmental Administration, Water Corporation and other enterprises.
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628