NIBP / SPO2 / Pulse Rate Lightweight Portable Patient Monitor PM-70

Feature

■ Routine Check Mode and Continuous Monitoring Mode
■ Data Graph and Trend Table Review
■ Rich Analysis Report
■ Sync with PC based Sofrware (WinXP and WinVista)
■ lightweight and easy-to-use portable unit
■ Built-in NIBP module
■ Automated & on-demand NIBP measurements
■ User or system-defined inflation pressure
■ ECG is optional

NIBP:

■ Performance Specifications
■ Display:3.5" Color TFT
■ Resolution:320x240
■ Display Mode:Standard face, Waveform face 
■ Indicator:Power indicator light, Alarm sound, Pluse tone
■ Interface:socket for connecting sensors and sockets for communication cables
■ Power Supply:DC 5V, <300mA
■ Battery:Builtin Li-Polymer, 2 hours for charging, 3 hours 
■ for continous working.8 hours for standby mode
■ Trend Graph:Resolution from 1s, 5s, 10s. Maximum time 96 hours.
■ Trend Table:Resolution from 1s, 5s, 10s. Review up to 1000 items.
■ Alarm:Ajustable High and Low limits. Three level audible and vistual alarm 
■ User Configuration:All the color of parameters and waves can be set according to user's willing

Technical specifications:

■ Safety
■ Meet the requirment of IEC60601 series
■ Type of Protection:Class II with internal electirc power supply
■ Degree of Protection:BF
■ Dimention and Weight
■ Dimention:145(W)x95(H)x37(D)mm
■ Weight:400g(with battery)
■ Operation Environment:
■ Temperature:0℃~ +40℃
■ Humidity:15% ~ 95%
■ Storage Environment:
■ Temperature:-20℃~ +60℃
■ Humidity:10% ~ 95% 
■ Patient Range
■ Neonate ,Pediatric and Adult

SPO2:

■ Measurement Range:0 ~ 100%
■ Resolution:1%
■ Accuracy:±2%(70%~100%, Adult/Pediatric, non-motion)
±3%(70%~100%, Neonate, non-motion)0% ~ 69% unspecified
■ Alarm Range:0% ~ 100%
■ Refreshing Rate:1s

Pulse Rate:

■ Measurement Range:25 ~ 250 bpm
■ Resolution:1bpm
■ Accuracy:±3 bpm (non-motion)
■ Alarm Range:25 ~ 250 bmp
■ Refreshing Rate:1s

NIBP:

■ Method:Oscillometry
■ Mode:Manual/Auto/Contiuous
■ Measurement Range:25 ~ 260mmHg
■ Atuo Measure Interval:5, 10, 15, 30, 45, 60, 90 ¡öminutes
■ Resolution:1mmHg
■ Overpressure Protection: 300mmHg
■ Alarm range: 25 ~260mmHg