Specifications NEW 2013
2 Channels DALI LED Driver
Constant Current 12V-48V DALI Dimmer
Current output 350mA 700mA Optional
Max. 24W/72W
Model: DL8006 NEW 2013 2 Channels DALI LED Driver Constant Current 12V-48V DALI Dimmer 350mA 700mA Optional
Features 1. Two channels constant current 350 MA or 700 MA output. 2. DALI digital control input, dimming control LED module. 3. Addressing output channel. 4 .Dimming light from 0-100% range, (LED brightness start from 1% ). 5. Used for DC power supply, over-temperature protection, safety level is 2. 6. Support TOUCH DIMMER(220VAC dimming way). 7. Custom-made available Tech-parameter
Input: DC12-48V | Output: 350mA 700mA Optional | Control channels:2CH |
MAX Power: 24W/72W Optional | Frequence: 500HZ | Signal Input: DALI Signal & 220V Switch |
Out casting temp: MAX70°C | Surrounding temp:-20--50°C(It is available in 25°C indoor). | Protection grade: IP40 |
Dimming control DALI definition:IEC62386 |
Size
Touch Dim functional description 1).Short press the Touch DIM switch(<0.5s)to control the lamp on or off. 2).Long press the Touch DIM switch(>0.5s)to dim the brightness of light;The dimming direction will change every time after pressing switch. 3).When the light being turned off,long press the Touch DIM switch can turn on the light and adjust the brightness according to the dimming direction. 4).The brightness adjustment range is 1%-100%,and the light can be turned off through short pressing when do the adjustment with long pressing Touch DIM switch. 5).Power off memory function,the power-down state before will be maintained when power on again. Product installation notes 1).Remark:DALI and Touch DIM functions can’t be used simultaneously,which can be controlled respectively by using DALI controllers or equipments with Touch DIM function. 2).Please read the connecting instruction picture before installation. 3).Please use the complete set of product according to the provided specification. 4).Please firstly pressure the cap end down in wire connecting process,then insert the thread of wire,and lastly check the wire is or not insert firmly. 5).In order to avoid the damage of the equipment,please check the connecting method is correct or not before connecting the power. 6).The DALI bus is using BV 2 x1. 5 mm wire, the longest distance is 300 meters. Wiring Diagram
Exception Handles
Malfunction | Causation | Solution |
No light | 1. No power from plug 2. At black mode 3. Overload Recovery 4. Incorrect connection | 1 Change the socket 2. Change the running mote 3 Lighten load, react 4 Check the connection |
About Us
Our Service: 1. Professional buying advice according to your needs. 2. Instant response to your inquiries. 3. Short lead-time, quick delivery. 4. Three years warranty for all of our products. 5. Samples orders, OEM/ODM orders are also welcomed.