Medical 3 Part Hematology Analyzer Blood Cell Counter
Medical 3 Part Hematology Analyzer Blood Cell Counter
Medical 3 Part Hematology Analyzer Blood Cell Counter
Medical 3 Part Hematology Analyzer Blood Cell Counter
Medical 3 Part Hematology Analyzer Blood Cell Counter
Medical 3 Part Hematology Analyzer Blood Cell Counter
Medical 3 Part Hematology Analyzer Blood Cell Counter

Video

1 / 5

Medical 3 Part Hematology Analyzer Blood Cell Counter

  • $3000.00

    ≥1 Set/Sets

  • $2800.00

    ≥5 Set/Sets

  • $2700.00

    ≥10 Set/Sets

Options:

  • Whole blood mode
  • Pre-diluent mode
  • L-J QC
  • X-B QC
  • 3 catagories
  • 21 parameters
Send Inquiry
Model No. : DH36
Brand Name : Dymind
Types of : Blood &Amp; Gas Analysis System
place of origin : China
Medical device classification : Class Ii
Warranty Service : 1 Year
After-sales service : Online Technical Support
3-Part : yes
blood sample volume : 6μL
Power : 40W
Weight : T16kgs
More
2yrs

Changchun, Jilin, China

Visit The Store
  • Gold Supplier
  • Platform Certification

Product description

Product description

Fully automatic blood analyzer, clinical also known as fully automatic blood cell analyzer or fully automatic blood cell analyzer. With the rapid development of science and technology, the technology of blood cell analysis has changed from three-classification several years ago to five-classification now, moving from two-dimensional space to 3D, many modern blood cell analyzers employ advanced techniques such as sheath current and laser technology

Important points

In order to ensure that the results obtained by the blood cell analyzer can reflect the real situation of patients as far as possible, the following aspects must be paid attention to when using the blood cell analyzer: 

1. Blood sample: because the external factors have little influence on the venous blood, the composition is relatively stable, the accuracy of the test results is high and repeatable, therefore, except for infants, the proposed blood should be taken by venous blood. If the collection of no tip blood, pay attention not to local over-extrusion, avoid blood mixed with a lot of tissue fluid, and easy to activate the coagulation system to produce local coagulation, resulting in errors in the detection results; The first drop of blood should be discarded because of the instability of the cellular component, and the second drop of blood should be tested.

2. Anticoagulation: the use of citrate anticoagulant too long, easy to crystallize, cell morphology changes, affect the accuracy of counting results; oxalate easy to platelet aggregation, and can change the morphology of white blood cells, excessive heparin can cause leukocytes agglutination and thrombocytopenia, EDTA-2Na is less soluble than EDTA-2K, and platelet agglutination is more likely. Therefore, the International Committee for Haematological Standards (ICSH) published a document in 1993 recommending the use of EDTA-2K as an anticoagulant for hematology analyzers in doses of 1.5-2.2 mg/ml of blood. 

3. The blood was sealed with a plug and kept at room temperature for no more than 6 hours.

4. Dilution: the diluent and the sampling tube should be calibrated. After sucking blood, the blood outside the suction tube should be completely wiped clean. Hemodilution should be determined as soon as possible, otherwise easy to cause“Dilution hemolysis.”. 

5. Mixing: it is important to mix well before testing. If there is no rotary blender, mix it upside down at least 8 times. 6. Reagents: the hematology analyzer requires very strict reagents, requiring a strict osmotic pressure standard, stable conductivity, high standards of purity and no corrosion of the instrument pipeline and valve. Therefore, the best choice of hemolytic, diluent and cleaning agents, such as the original factory supporting products.

Seven. Classification of white blood cells: first of all, it must be clear that up to now, no matter how advanced blood cell analyzer in the world, the classification of white blood cells is only a screening method, and can not completely replace manual microscopy classification. We must resolutely correct the mistaken idea that some units lose microscopic examination when they use blood cell analyzer. 8. Quality Control: blood analysis must establish a strict quality control system in order to ensure the reliability of the results.


Detailed picture


Dh36 Jpg



DH36-1

Technique parameters

DH36-2

Transportation

R-C (1)

Welcome to inquire

R-C

Company Overview

Jilin Sinoscience Technology Co., Ltd. is a high-tech enterprise specializing in the research, production, sales and service of  Laboratory Diagnostic products. We were established in Changchun in 2021. Our main products are in vitro diagnostic reagents and instruments,including COVID-19 Medical ProductsMedical Instruments And Equipment, Laboratory DiagnosticMedical Consumables. We have more than 70 reagents in the field of IVD and continue to develop automatic chemical analyzers, urine analysis products, etc. We are committed to becoming one of the best suppliers in the IVD industry, providing various series of products with advanced technology and first-class quality. We have more than 6 production lines which are urine analyzer series,chemistry analyzer series,hematology analyzer series,Reagent Strips for Urinalysis series,rapid tests series,COVID-19 Medical Products series.At the same time, we also hope to become a third-party medical testing center that provides regional medical testing services, equipped with self-developed regional LIS system, modern disinfection center, cold chain logistics system, cloud platform and other supporting systems.

R-C (2)

office-1

Exhibtion

Exhibitions

Workshop

Workshop

Certificate

Urine Test



Video

Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628