1 / 1
Model No. : | KGG3G |
---|---|
Brand Name : | Rifeng |
Product description
Type | Name |
KGG | Copper Core Silicon Rubber Insulation and Sheath Control Cable |
KGGP | Copper Core Silicon Rubber Insulation and Sheath Braided Shield Control Cable |
KFFP2 | Copper Core Silicon Rubber Insulation and Sheath Copper Strips Shield Control Cable |
KGG2G | Copper Core Silicon Rubber Insulation Steel Tape Armoring Silicon Rubber Sheath Control Cable |
KGG3G | Copper Core Silicon Rubber Insulation Steel Wire Armoring Silicon Rubber Sheath Control Cable |
KGGR | Copper Core Silicon Rubber Insulation and Sheath Control Flexible Cable |
KGGRP | Copper Core Silicon Rubber Insulation Braided Shield Silicon Rubber Sheath Control Flexible Cable |
Item | Code | Description |
Material code | K | / |
Ellipsis | Copper Conductor | |
G | Silicon Rubber Insulation | |
G | Silicon Rubber Sheath | |
Construction code | A | Class 1 Conductor |
B | Class 2 Conductor | |
R | Class 5 Conductor (Soft Structure) | |
P | Braided Shield | |
P2 | Copper Tape Shield | |
P3 | Aluminum Plastic Composite BeltShield | |
3 | Thin Steel Wire Armoring |
AC. Rated Voltage | Conductor Max Temperature | Conductor Max Temperature at Short Circuit(5s) | Minimum Bending Radius | |
Non-Armored, Shield | With Armored or Shield | |||
≤0.6/1KV | 180℃ | 350℃ | ≥6 times of cable O.D. | ≥ 12 times of cable O.D. |
Type | Nominal Cross Section of Conductor (mm2) | |||||||
0.5 | 0.75 | 1.0 | 1.5 | 2.5 | 4 | 6 | 10 | |
No. of Cores | ||||||||
KGG KGGP | — | 2~61 | 2~14 | 2~10 | ||||
KGGP2 | — | 4~61 | 2~14 | 2~10 | ||||
KGG2G | — | 7~61 | 4~61 | 2~14 | 2~10 | |||
KGGP2-2G | — | 7~37 | 4~37 | 2~14 | 2~10 | |||
KGG3G | — | 7~37 | 2~14 | 2~10 | ||||
KGGR | 2~61 | — | — | |||||
KGGRP | 2~61 | 2~48 | — | — | ||||
Recommend No. of cores: 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 37, 44, 48, 52, 61 |
Item | Unit | Parameter | |||||||||
No. of Cores | - | 2~61 | |||||||||
Conductor cross section | mm2 | 0.5 | 0.75 | 1.0 | 1.5 | 2.5 | 4 | 6 | 10 | ||
Conductor DC resistance at 20℃ ≤ | Class A or B Conductor | No tinning | Ω/km | 36.0 | 24.5 | 18.1 | 12.1 | 7.41 | 4.61 | 3.08 | 1.83 |
Tinning | 36.7 | 24.7 | 18.2 | 12.2 | 7.56 | 4.61 | 3.08 | 1.84 | |||
Class R Conductor | No tinning | 39.0 | 26.0 | 19.5 | 13.3 | 7.98 | - | - | - | ||
Tinning | 40.1 | 26.7 | 20.0 | 13.7 | 8.21 |
|
| - | |||
Insulation Resistance Constant at 20℃ | MΩ·km | ≥1500 | |||||||||
Insulation Resistance at Working Temperature | ≥0.15 | ||||||||||
Test Voltage 50Hz | V, min | ≤450/750V, 2500V, 5min: No Breakdown; 0.6/1kV, 3500V, 5min: No Breakdown | |||||||||
Insulated Core Soaking AC. Voltage Test (soaking ≥1h) | V, h | 450/750V, 2000V, 4h: No Breakdown; 0.6/1 kV, 2400V, 4h: No Breakdown; |
Send your inquiry to this supplier