Product description

Flame retardant Low smoking and halogen free power cable Product Description Application: It is suitable for transmission line with a rated AC voltage U0/U 3.6/6KV and below. Executive Standard: GB/T12706-2008 ,equivalent to IEC502(83) Operational Performances: 1. Working temperature: For general type, not over 70°C as the maximum For 105°C flame-retardant material, not over 105°C as the maximum For 135°C flame-retardant material, not over 135°C as the maximum 2. Lowest ambient temperature:-40°C for fixed laying,-20°C for non-fixed laying 3. Rated voltage U0/U:0.6/1kV, 3.6/6kV 4. Min.bending radius:not less than 10 times of outer diameter of cable if without armor, and not less than 15 times of cable outer diameter provided the cable is armored. 5.Short-circuit condition:The maximum temperature of cable conductor will not exceed 175°Cunder short-circuit condition(longest time of 5 seconds)   Main Technical Data 1,Material: Table 1:Flame-retardant Technical Data of Varieties of Materials

Item

Technical Data

General flame-retardant PVC

Low smoke and low halogen material

Low smoke and halogen-free material

Oxygen index(%)

30-20

31-33

36-40

Smoke density

600

300

With flame:50

without flame:260

Hydrogen halide release (mg/g)

580

100

0.5

  2,Product Table 2:Main Performances of Product

Serial   No.

Item

Performance  

1

Structure  

Attached   Sketch*

2

Conductor   resistance

As per   GB3956-1996

3

Voltage-withstand   test

 

No   breakdown

4

Mechanical      

Tensile   strength

Insulation  

Min.12.5N/mm2

Sheath

Min.12.5N/mm2

Elongation   at break

Insulation  

Min.150%  

Sheath

Min.150%  

Mechanical   property after aging

Tensile   strength

Insulation  

100°C±2°C,Min. 12.5N/mm2 in 7 days

Sheath

100°C±2°C,Min. 12.5N/mm2 in 7 days

Change   rate

Insulation  

100°C±2°C,Max.±25% in 7 days

Sheath

100°C±2°C,Max.±25% in 7 days

Elongation   at break

Insulation

100°C±2°C,   Min.150% in 7 days

Sheath

100°C±2°C,   Min.150% in 7 days

5

Flame-retardant   feature

In   compliance with GB/T12666.5-1990(Type CB) and IEC332-3 (Type CB)

 

Insulation   resistance constant Ki MΩ·km

Minimum   at 20°C

36.7

At 70°C

0.037

                          3,Color Code of Insulation Core: Complies with Requirements of National Standard GB6995.5-86

2-core

Red,Blue

4-core

Red,Yellow,Green,Blue

3-core

Red,Yellow,Green

5-core

Red,Yellow,Green,Black,Blue

  4,Vary in cross-section area, the four and five's             5,Basic Type and designation

Type

Designation   of product

VV

Cu core   PVC insulated&sheathed power cable

VLV

Al core   PVC insulated PVC sheathed power cable

VV22

Cu core   PVC insulated&sheathed armored power cable

ZR105-VV

Cu core   flame-retardant (105°C)PVC insulated&sheathed power cable

ZR135-VV  

Cu core   flame-retardant (135°C)PVC insulated&sheathed power cable

ZR105-VV22

Cu core   flame-retardant(105°C)PVC insulated&sheathed armored power cable                

ZR135-VV22  

Cu core   flame-retardant(135°C)PVC insulated&sheathed armored power cable

ZR105-VLV22  

Al core   flame-retardant(105°C) PVC insulated&sheathed power cable

ZR135-VLV22

Al core   flame-retardant(135°C)PVC insulated&sheathed power cable

ZR105-VDVD

Cu core   low-smoke&halogen PVC insulated&sheathed power cable

ZR135-VDVD

Cu core   low-smoke&halogen 135°C PO insulated&sheathed power cable

ZR105-VDVD22

Cu core   low-smoke&halogen PVC insulated&sheathed steel tape armored power   cable

ZR135-VDVD22

Cu core   low-smoke&halogen 135°CPO insulated&sheathed steel tape armored power   cable

VV32

Cu core   PVC insulated&sheathed thin steel wire armored power cable

VV42

Cu core   PVC insulated&sheathed thick steel wire armored porter cable

ZR105-VV32  

Cu core   flame-retardant (105°C)PVC insulated and sheathed thin steel wire armored   power cable

  Type explanation   Code and definition

Item

Code

Definition  

Flame-retardant   code

/

ZR

Non   flame-retardant can he omitted

Flame-retardant  

Insulation   material

V

VD

PVC

Low-smoke   & halogen material

Sheath   material

V

VD

PVC

Low-smoke   & halogen material

Armor   material

22

32

42

Steel   tape armor

Thin   steel wire armor

Thick   steel wire armor

Class   of heat-resistance

70

90

105

135

Max.   operating temp. is 70°C

Max.   operating temp. is 90°C

Max.   operating temp. is 105°C

Max.   operating temp. is 135°C

Rated   voltage

0.6/1kV   3.6/6kV

Rated   voltage U0/U is 0.6/1kV

Rated   voltage U0/U is 3.6/6kV

      2.the construction of the power cable for different voltage grade 2.1 low  voltage  cable power cable Low voltage (0.6/1 kv) single core or multi-core copper or aluminium conductor pvc inusulation steel tape armored or galvanized steel wire armored or unarmored pvc outer sheath power cable. 2.2 medium voltage cabel power cable Voltage grade is up to 35kv, cross-section area can be up to 1000 sqmm  (copper or aluminiun conductor). Conductor long-time  operating temperature is 90 degrees. In short circuit, conductor  highest temperature should be not more than 250 degrees. 1kv-35 kv  multi-cores copper or aluminium conductor xlpe insulation copper tape or copper wire screen  galvanized steel wire armored pvc or pe sheath power cable 2.3 high voltage cable power cable High voltage (35kv~220kv)  copper or aluminium conductor xlpe insulation metal sheath (lead or corrugated aluminium) hdpe or pvc outer sheath power cable. Laying conditions: for lyaing  under ground with large different  altitude, be able to bear external machanical force and moderate pulling force.    

Packaging Detail:

international wooden drums or according to your requirement.

Delivery Detail:

In one month or as the quantity you required.


    Attention: 1.Caused by floating market prices of raw materials, product price changes, please confirm offer in order to come to the electric company with me, so as to avoid inconvenience and losses due to price changes.  2. Storage instructions 1) cable should be avoided in open air, cable is not allowed to lie flat. (2) transport forbidden dropped from a height in the cable, it is strictly prohibited to       mechanical damage cable. (3) when lifting package, it is forbidden to several segments at the same time.In vehicles, ships and other transportation cable must be steadier, and fixed properly, prevent bumping into overturned. 3. Acceptance of goods (1) the customer after getting goods, please carefully check face to face, with reference to the contract or invoice, confirming specifications specifications, quantity, color is correct, goods without damage before you sign for it, there is a problem refused to sign for it, or by the logistics back, and immediately contact our company.Once receipt, will not be allowed to request return for other reasons. (2) for the product itself quality problem can return, return part of the freight shall be borne by the seller.The loss caused by improper use by customers themselves, do not assume corresponding responsibility, not refund don't change. (3) what they sell are real shooting, by reason of color difference, shooting skills may cause pictures and in-kind nuances, such as the products buyers in doubt, can consult shopkeeper first. (4) for packaging characteristics of wire products, knitting products in with the rest of the goods in transit may produce slight mishap after extrusion, as long as the insulation surface found no scratches or broken, you may rest assured to use.      FAQ    Marking Examples: Example 1:Copper-core PVC insulated and sheathed steel-tape armored 3+1 type, main core section is 50mm2 and that of neutral core is 25mm2, such power cable can be represented by: VV22 3X50+1X25 Example 2:Rated voltage is 0.6/1kV copper-core flame retardant(135°C)PVC insulated and sheathed, small-gauge steel wire armored, 4+1 type, main core section is 70mm2 and that of neutral core is 35mm2, such power cable can be represented by: ZR135-VV 0.6/1kV 4 X 70+1x35   Example 3: Rated voltage is 0.6/1kV, copper-core flame-retardant(105°C)PVC insulated and sheathed, steel tape armored, 3+2 type, main core section is 185mm2 and that of neutral core is 95mm2, such power cable can be represented by: ZR105 -VV22 0.6/1kV 3 X 185+2 x 95   Example 4: Rated voltage is 0.6/1kV, aluminum core PVC insulated and sheathed, 3+1 type, main core section is 50mm2 and that of neutral core is 25mm2, such power cable can be represented by: VLV 0.6/1kV 3 X 50+1 X 25   Example 5: Rated voltage is 0.6/1kV,aluminum core flame-retardant PVC (105°C)insulated and PVC sheathed power cable with main core section to be 50mm2 and that of neutral core is 25mm2, it can be represented by: ZR105-VLV 0.6/1kV 3 X 50+1 X 25   Example 6: Rated voltage is 0.6/1kV,aluminum core flame-retardant PVC (135°C)insulated and PVC sheathed power cable with main core section to be 50mm2 and that of neutral core is 25mm2, it can be represented by:ZR135-VLV 0.6/1kV 3 X 50+1 x 25     Our Services  Special cables can provide installation service if needed.     Company Information
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628