fixed chlorine gas detector
fixed chlorine gas detector
fixed chlorine gas detector
fixed chlorine gas detector
fixed chlorine gas detector
fixed chlorine gas detector
fixed chlorine gas detector

1 / 5

fixed chlorine gas detector

Get Latest Price
Send Inquiry
Model No. : TGas-1031-CL2
Brand Name : globeinstrument

Product description

fixed chlorine  gas detector    Brief Introduction TGas-1031 on-line gas transmitter which adopts high performance sensor unit can continuously measure the concentration of gas on site and convert the concentration signal into digital or analog signal output(4-20mA analog signal,RS485 communication signal and switch quantity alarm signal to transmit remotely and drive). Main Features u  Two kinds of optional mode of power supply, including centralized busbar type and independent area type u  High and low concentration alarm, performing real-time monitor to gas u  Anti-poisoning type gas sensor with high sensitivity u  Automatic modification of ageing curve of sensor, keeping constant alarm sensitivity u  Function of automatic recognition of sensor trouble, function of high concentration gas above-norm of sensor u  Function of automatic detection at starting up, and it has advanced function of self-diagnosis and self-reparing u  The calibrated concentration value is adjustable, facilitating users to set by themselves Technical Parameters

Parameters

Characteristics

Detectable gas

Flammable gases, oxygen, poisonous and harmful gases

Measurement precision

±5%F.S

Repeatability

2%

Measurement range

Refer to lectotype table for details

Response time

<30s(T90)

Sampling method

Diffusion

Working environment

Temperature: -30 ~ 60

humidity: below 85% (non condensation)

Remote control mode

By the adjustment mode by infrared remote control, the detector can be adjusted without opening of cover

4 ~ 20mA

output

4~20mA output corresponding to 0 ~100%

 maximum load 800 ohms

Alarm output

The effective alarm is 1 point or 2 points; each alarm shall use SPDT electronic relay.

Contact rating of alarm relay:

Ohmic load: 5A@24VDC or 120VAC or 240VAC

Inductive load: 50VA

Communication

Communication description: three-wire system parallel RS485 protocol, 32 points at most

Connection: Twisted pair with shield

Distance: maximum 1000m

Input voltage

24VDC±25%; power: 2W/way

Explosion-proof shell

Explosion-proof grade: ExdIICT5

Protection class: IP66

Using cable

≥2.5mm2×4 screened cable line, outside diameter of cable is required to be between 6mm~9mm

  Lectotype Table(part gas)

Model

Range

Low alarm

 setting range

High alarm

setting range

Low

alarm point

High

 alarm point

TGas-1031-FL

0~100%LEL

5%~10%LEL

25%~80%LEL

20%LEL

50%LEL

TGas-1031-H2

0~1000ppm

100ppm~300ppm

400ppm~600ppm

100ppm

500ppm

TGas-1031-O2

0~30%vol

16%~19.5%vol

22.5%~24%vol

19.5%vol

23.5%vol

TGas-1031-CO-1

0~500ppm

25ppm~100ppm

100ppm~500ppm

35ppm

200ppm

TGas-1031-CO-2

0~1000ppm

25ppm~100ppm

100ppm~500ppm

35ppm

200ppm

TGas-1031-CO2-1

0~5%vol

1000~2500ppm

2500~5000ppm

1500ppm

2500ppm

TGas-1031-CO2-2

0~20%vol

4%~8%

8%~16%

5%

10%

TGas-1031-CO2-3

0~65%vol

13%~26%

26%~52%

15%

30%

TGas-1031-CO2-4

0~100%vol

20%~40%

40~80%

30%

50%

TGas-1031-H2S

0~100ppm

5ppm~15ppm

15ppm~30ppm

10ppm

15ppm

TGas-1031-SO2

0~20ppm

1ppm~3ppm

3ppm~10ppm

2ppm

5ppm

TGas-1031-CL2

0~10ppm

0.5ppm~3.5ppm

4ppm~6ppm

0.5ppm

5ppm

TGas-1031-NH3

0~100ppm

20ppm~30ppm

30ppm~70ppm

25ppm

50ppm

TGas-1031-NO

0~250ppm

20ppm~50ppm

50ppm~100ppm

25ppm

50ppm

TGas-1031-NO2

0~100ppm

1ppm~2ppm

2ppm~5ppm

1ppm

2ppm

TGas-1031-HCN

0~30ppm

5ppm~10ppm

10ppm~15ppm

5ppm

10ppm

TGas-1031-PH3

0~1ppm

0.3ppm~0.5ppm

0.5ppm~0.8ppm

0.3ppm

0.6ppm

  Executed Standards(GB Standard is China National Standard) GB12358-2006: General Technical Requirements for Gas Detector in Workplace Environments GB3836.1-2000: Electrical apparatus for explosive gas atmospheres Part 1 General Requirements GB3836.4-2000: Electrical apparatus for explosive gas atmospheres Part 2 flame-proof type "d"   The product is inspected and tested by the state legal authority and it pass the explosion-proof certification. The mark of explosion-proof is ExdIICT5.It applies to 0 zone,1 zone,2 zone,the place that contains IIA~IIC category and T1~T5 group of explosive gas mixture.It is qualified to get explosion-proof conformity certificate through inspection by CQST.Protection class of shell is IP66. Package: Model details:   Payment Terms: T/T, Western union, Paypal, L/C   Shipping:TNT,UPS,DHL,Fedex and othercourier available as required.   Delivery time:3-5 days after your full payment.   COMPANY INFORMATION:   Our company was established in 2004, engaged in researching and developing high quality air-sensitive technology. Our company has first-grade equipment, scientific methods, project management system and excellent employees. Our main products are gas-leakage detectors and gas analyzers, and are widely used in industrial field and chemical industry. Our company is always ready for supplying excellent products and professional service   EXHIBITION         COMPANY CERTIFICATES   Why choose us?   -NO limit MOQ   -OEM or ODM Service   -Fast delivery with top quality   -Flexible payment method, Paypal can be accepted   -1 Year free warrenty of all the products   -Professinal after-sale service   Contact with us!    