1 / 3
Model No. : | ADP |
---|---|
Brand Name : | IDEALTEKNIC |
Circuit Mode : | Power Transformer And High Frequency |
Yangzhou, Jiangsu, China
Product description
ADP Series Capacitor Ripple Current Endurance Test Power Supply
Overview
ADP series is specially designed for ripple current endurance test of different kinds of capacitors, such as metal film capacitors and film capacitors, it has wide output voltage, current and frequency range to meet various test requirements.
This series Capacitor Test Power Supply has Max. DC output voltage up to 3000V, Max. AC output voltage up to 400V, Max. AC output current up to 400A, and output frequency optional from 50Hz to 1KHz.
This series test power supply is equipped with high frequency & high temperature fixture and connection line for good simulation of capacitor working conditions in groups of ripple current test to improve test efficiency, so that accuracy test parameters could be provided to users and capacitor manufacturers.
Features
l DC/CV/CC, CV/CC value continuously adjustable from 0 to rated value.
l AC/CV/CC, CV/CC value continuously adjustable from 0 to rated value.
l Over voltage protection: Automatic protected and alarm when output voltage exceeds 110% rated value.
l Over current protection: Automatic protected and alarm when output current exceeds 110% rated value.
l Over temperature protection: Automatic cut off output and alarm when working temperature exceeds protection threshold value.
l AC pine sine wave fixed frequency output: frequency scope: 50Hz/60Hz/100Hz/120Hz/200Hz/400Hz/1KHz for selection, or user could select 45.0 ~ 1KHz adjustable.
l When output frequency is above 1KHz, output frequency cannot be continuously adjustable, client could only select at most five high-frequency values in one power supply, output frequency values selected by transfer switch.
l AC/DC output both digital display, high accuracy and reliable.
l AC/DC automatic mixed output, no need for external connection.
l Automatic timing of test time.
l Automatic cut off AC & DC output and alarm when preset time reached, also time would be saved.
When power supply or load is faulty or short-circuit, output would automatically cut off, timer stops timing and save time value.
l Short alarm: Automatic cut off AC & DC output and sound & light alarm when output is short-circuited.
Applications
l Film capacitor ripple current endurance test.
l Metal capacitor ripple current endurance test.
Specifications
Input |
Voltage |
Single – phase 220Vac±10% or Three – phase 380Vac±10% |
Frequency |
50Hz±10% |
|
Output |
Output terminal |
AC & DC mixed output on front panel. |
DC voltage adjusting range |
Max DC output: as requirements |
|
AC current adjusting range |
One-side Max. AC output: as requirements |
|
DC Part |
||
Accuracy (C.V.) |
Line regulation |
≤0.1% Of the rated value ± 1 digit (output voltage change ratio under input ±10% change) |
Stability |
≤0.3% of the rated value (output voltage change ratio due to 8 hours continuously working) |
|
Temp. coeff.offset (within 30mins) |
≤0.4‰/℃ of the rated value ± 2 digits (output voltage change ratio due to environment temperature changes) |
|
Load regulation |
≤0.2% of the rated value ± 1 digit (output voltage change ratio due to output current change from 0 to rated value) |
|
Accuracy (C.C.) (Optional) |
Line regulation |
≤0.1% Of the rated value ± 1 digit (output current change ratio under input ±10% change) |
Stability |
≤1% of the rated value (output current change ratio due to 8 hours continuously working) |
|
Temp. coeff.offset (within 30mins) |
≤0.4‰/℃ of the rated value ± 2 digits (output current change ratio due to environment temperature changes) |
|
Load regulation |
≤0.2% of the rated value ± 1 digit (output current change ratio due to output current change from 0 to rated value) |
|
Ripple + noise (r.m.s) |
≤0.01% of the rated value+10mV (80%~100% rated output) |
|
Output voltage adjusting range |
Adjustable (0~rated value) |
|
Output current adjusting range |
Adjustable (0~rated value) (optional) |
|
Automatic timing range |
1 ~ 9999 hours |
|
Adjusting mode |
10-turn Potentiometer |
|
Protection functions |
Output will be cut down when over voltage / over current |
|
Short alarm |
Withstand short-circuit and alarm |
|
Working mode |
Withstand long-term continuous working at full load. |
|
Output voltage & current display |
Digital LED |
|
Display precision |
As per output values |
|
Display error |
≤±1%±1digit (range:1%~100% of the rated value) |
|
Total display error |
≤±0.01% |
|
AC Part |
||
Output voltage adjusting range |
1% ~ rated voltage continuously adjustable |
|
Output current adjusting range |
1% ~ rated current continuously adjustable |
|
Adjusting mode |
10-turn Potentiometer |
|
Output waveform |
Sine wave (distortion≤5% measured @ full power output) |
|
Output frequency |
50Hz ~ 1KHz. Fixed output frequency levels when output frequency goes beyond 1Khz (Max. 5 levels) such as 5KHz/10KHz/15KHz/20KHz/30KHz…up to 100KHz (Frequency error ≤±1%) |
|
Output voltage & current display |
Digital LED |
|
Display precision |
As per output values |
|
Display error |
≤±1.5%±2digits (range:1%~100% of the rated value) |
|
Protection functions |
Output will be cut down when over voltage / over current |
|
Working mode |
Withstand long-term continuous working at full load. |
|
Load characteristic |
Capacitive load |
|
Environment conditions |
Indoor use only Temperature: -20℃~40℃ Humidity: ≤80% |
|
l Input Voltage: Power source voltage can be changed to others on request. |
Standard Model list
Type |
DC Output |
AC Voltage |
AC current |
Frequency |
Output power |
Optional functions |
Remarks (if any) |
ADP (low frequency) |
DC3000V1.5A (Max. output) |
10 ~ 100V |
5 ~ 100A |
45-1000HZ continuously adjustable Fixed frequency levels 50 / 60 / 100 / 120 / 200HZ settable |
0 ~ 20KW |
1. Coarse / Fine adjusting 2. Start-up timing: 1 ~ 9999 hours |
|
10 ~ 200V |
5 ~ 50A |
|
|||||
10 ~ 50V |
5 ~ 200A |
|
|||||
15 ~ 200V |
5 ~ 10A |
100KHz |
0 ~ 5KW |
|
|||
10 ~ 50V |
5 ~ 50A |
|
|||||
10 ~ 100V |
5 ~ 100A |
45-1000HZ continuously adjustable Fixed frequency levels 50 / 60 / 100 / 120 / 200HZ settable |
0 ~ 20KW |
|
|||
10 ~ 400V |
5 ~ 50A |
|
|||||
10 ~ 50V |
5 ~ 200A |
|
|||||
DC600V1A |
50V |
5A |
50 ~ 999.9Hz |
|
|
|
|
100V |
2A |
|
|
|
|||
DC800V1A |
30V |
60A |
|
|
|
||
ADP (high frequency) |
DC3000V1.5A (Max. output) |
15V |
500A |
5KHz / 8KHz |
15KW |
1. Coarse / Fine adjusting 2. Start-up timing: 1 ~ 9999 hours |
|
15V |
400A |
Max. 5 frequency levels within 5KHz ~ 20KHz |
12KW |
Client needs to provide load for testing if AC current goes beyond 300A |
|||
15 ~ 20V |
300A |
||||||
15 ~ 30V |
200A |
||||||
10 ~ 200V |
5 ~ 10A |
20KHz / 40KHz / 60KHz / 80KHz / 100KHz |
4KW |
These outputs cover the models whose output frequency go beyond 40KHz. |
|||
10 ~ 100V |
5 ~ 20A |
||||||
10 ~ 50V |
5 ~ 50A |
||||||
l Please contact us in case custom-made required. |
Yangzhou, Jiangsu, China
Send your inquiry to this supplier