Product: Power surge protection Model: KIN-BC13
KIN-BC13 380V, 3+NPE, 36mm
KIN-BC13 380V, 36+18mm
KIN-BC13 380V, 36mm Application: THE KIN BC13 is a B + C class pressure limiting power surge protector, it can be used as the first or second class protection of the load equipment power lines, usually installed in smaller building overall space occasions. Not only can withstand a high lightning current, but also has a characteristics of the low voltage level of protection. Features: Built-in over current, overheating , failure tripping device , safe, reliable and non-fire trouble . Optional interface remote telesignalling . Visualization window , colorless normal indicates, red deterioration indicates. High lightning capacity and fast response speed. No freewheeling , low residual voltage , long life. Modular , Kevin wiring , 35mm rail mounting design . Specifications:
Model | KIN BC13 |
Specs | 380V, 36mm | 380V, 3+NPE, 36mm | 380V, 36+18mm |
Protection degree | B+C | B+C | B+C |
Voltage rating Un(V) | 380 | 380 | 380 |
Maximum continuous operating voltage Uc(V) | 385 | 385 | 385 |
Nominal discharge current(8/20μs)In(kA) | 80 | 80 | 80+40 |
Maximum discharge current(8/20μs)Imax(kA) | 140 | 140 | 140+80 |
Voltage protection level Up(kV) | 2.0 | 2.0 | 2.0 |
Response time t(ns) | <25 | <25 | <25 |
Protected mode | L-PE, N-PE | L-N, N-PE | L-PE, N-PE |
canning material | PBT flame retardant plastics | PBT flame retardant plastics | PBT flame retardant plastics |
Protection level | IP20 | IP20 | IP20 |
Installation | 35mm Electric rail | 35mm Electric rail | 35mm Electric rail |
Mechanical interface | Screw crimp | Screw crimp | Screw crimp |
Working temperature(℃) | -40~+85 | -40~+85 | -40~+85 |
Installation: Cut off the power before installation, prohibited hot-line work. You'd better connect a automatic circuit breakers or fuse plug to the protector in series. Protector for parallel installation, recommended to adopt wany of Kevin wiring ( for the convenience of Kevin wiring, the module has two terminals , they are straight . Kevin -type connection is a shape of V, connected in a touch point, two lines in parallel , one counted, and another figure out ). The cable should be solid , reliable , and require a short , thick, straight. Install it according the connection diagram, where L (L1 , L2, L3) is the phase line, N is zero line, PE is ground line, mustn't be wrong connected. After the installation, close the automatic circuit breaker ( fuse ) switches. During the use, the protector should be regular tested and view the failure display window state, when the fault display window was red or remote signaling terminals output the alarm signal, indicating that the protection failure , shall promptly repair or replace.