Specifications Cat6 passing fluke testing Lan cable
1.Factory price
2.Top Quality
3ISO.ROHS.CE certificated. 4 Pair High Frequency UTP Cat6 Network cable Outdoor Lan cable UTP Network cable Pass FLUKE Test
Cat 6 Network Cable |
Size | Inner box | 38*38*24cm |
Outer box | 52*41*41cm |
Container packing quantity | 20ft(28CBM) | 643boxes |
40ft(58CBM) | 1333boxes |
40hq(68CBM) | 1563boxes |
FEATURES | |
TIA/EIA-568B.2-1;ISO/IEO 11801; Fire protection – IEC60332-1 (CM) Cable is used for indoor installation | |
CONSTRUCTION | |
Conductor: Bare Solid Copper Conductor Dia.:0.51mm±0.005mm (24AWG) Pair Insulation:Polyethylene Outer Cable Diameter: 5.7 ± 0.2 mm | Pair Identification: Pair1= Blue/White Pair2= Orange/White Pair 3= Green/White Pair4= Brown/White Outer Jacket: PE+PVC Compound Jacket Jacket Color:Black Color |
TECHNICAL CHARACTERISTICS | |
Installation Temperature: 0°C to +60°C Operating temperature: -20°C to +75°C DC Resistance Unbalance :5% Pair-to-Ground Capacitance Unbalance :330 pF/100 m Capacitance:14pF/ft nominal | Pulling strength: 130 N Minimum bend radius: 4 outer cable diameters Dielectric Breakdown:1000 Volts DC Conductor to Conductor Velocity of Propagation:PE=65% Maximum Skew:45ns@100 meters |
PACKAGING | |
305m/1000ft Easy pulling box; 500m/wooden reel;1000m/wooden reel |
ELECTRICAL CHARACTERISTICS |
Features
Frequency, MHz | RL | Attenuation, dB | NEXT, dB | PSNEXT, dB | ELFEXT, dB | PSELFEXT, dB |
0.772 | - | 1.8 | 67 | 64 | - | - |
1 | 20 | 2 | 65.3 | 62.3 | 63.8 | 60.8 |
4 | 23 | 4 | 56.3 | 53.3 | 51.7 | 48.7 |
8 | 24.5 | 5.8 | 51.8 | 48.8 | 45.7 | 42.7 |
10 | 25 | 6.5 | 50.3 | 47.3 | 43.8 | 40.8 |
16 | 25 | 8.2 | 47.3 | 44.3 | 39.7 | 36.7 |
20 | 25 | 9.3 | 45.8 | 42.8 | 37.7 | 34.7 |
25 | 24.3 | 10.4 | 44.3 | 41.3 | 35.8 | 32.8 |
31.25 | 23.6 | 11.7 | 42.9 | 39.9 | 33.9 | 30.9 |
62.5 | 21.5 | 17 | 38.4 | 35.4 | 27.8 | 24.8 |
100 | 20.1 | 22 | 35.3 | 32.3 | 23.8 | 20.8 |
FAQ Q: What is the maximum length for a Cat5e & Cat6 cable? A: The maximum length for a Cat5e & cat6 cable run is 100 meters (328 feet). If longer runs are required, the use of active hardware such as a repeater or switch is necessary. Q: What is the difference between solid and stranded cable? A: Solid cable is a 4-pair cable. Within each of the 8 individual wires there is a solid piece of wire covered by a PVC jacket. Because of the solid core of these cables they will be more rigid than stranded cable, but can carry a stronger signal than stranded wire. Solid cable also has the ability to be punched down in to jacks, patch panels, and 66 blocks. Stranded cable is a 4-pair cable as well. Within each of the 8 individual wires there are multiple tiny stands of smaller gauge wire that are held together by a PVC jacket. Because this cable is made with smaller strands of cable it is more flexible than solid core wire. Stranded Cat5e is typically use for short patch cables. Stranded wire cannot be punched down. Q: What is shielded cable? A: Shielded cable is used for increased protection from interference and crosstalk. It is typically used in electrical noisy environments. Common sources of interference are radio towers, high-powered electrical conduit, fluorescent lighting, or any other device emitting electro-magnetic or radio frequency signals. Q: What is SSTP Cat6a cable? Cat6a network cables enable 10-Gigabit data transmission over a 4-connector twisted-pair copper cable, allowing connection distances of up to 100 meters. Current Cat6 cabling systems may only support 10-Gigabit Ethernet over limited distances. The Cat6a draft extends the Cat6 electrical specifications from 250 MHz to 500 MHz. It also proposes a new measurement for Power-Sum Alien Crosstalk to 500 MHz. Alien Crosstalk is a coupled signal in a disturbed pair arising from a signal in a neighboring cable. Q: What is SSTP Cat7 cable? Cat 7, is a cable standard for Ethernet and other interconnect technologies and are still backward compatible with previous categories of networking (Cat 5, Cat 5e, Cat 6). These cables are designed to function at 10 Gigabit, over 100m of copper cabling. Cat-7 cabling supports frequencies of up to 600 Mhz and speeds of up to 10,000 Mbit/s. This is a big improvement on previous network cabling speeds (CAT 3: 10 Mhz, CAT 5: 100Mhz, CAT 6: 250 Mhz). Cat 7a cables can perform up to frequencies of 1000 Mhz and 40 Gbit/s. CAT7 cables feature even more strict specifications for crosstalk and system noise then CAT 6. This is achieved through shielding on the individual wire pairs and the cable as a whole. Category 7 is recognized for all the country organizations members of ISO.
Shenzhen Aucas Cables Co.,Ltd has been a professional manufacturer of Network Cables,CCTV Cables,Telephone Cables,Optical Cable and all the network cabling system accessories for over 10 years. Now Aucas has got two subsidiaries in Guangzhou(Guangzhou HSCOM Network Technology Co.,Ltd) and Taiwan(Aucas International Group Holdings Limited).