1 / 4
Model No. : | SVC |
---|---|
Brand Name : | Horizon |
Product description
Horizon New & Old Type Voltage Stabilizer Comparison | |||||
Same Part | No. | Technical | Old type | New type | Result |
1 | Input voltage range | 80V-250V(limit) | 40V-250V | New wider range | |
2 | Material | 100% copper | 100% copper | same material | |
3 | Using Style | hanging stype+Desktop type | hanging stype+Desktop typ | same style | |
4 | Size | 40.5*24*37(0.036 cube) | 30*22*40(0.0264 cube) | New type size shrinked 27% | |
Different Part | 5 | Over-voltage protection | NO | YES | |
6 | Power on delay | NO | YES | ||
7 | City electrcity | NO | YES | ||
8 | Circulation cooling | 50% | 70% | New type with load+10% | |
9 | Lowest working votlage | 80V display | 30V display | ||
10 | Limit starting | 180V-250V close,lowest starting votage 110V | 180V-250V close,lowest starting voltage 40V | New type excellent | |
11 | Motor short-circuit protection | always powered on unless the PCB damaged | PCB sprint intermittently then motor short-circuit.Power off the motor 2 minutes later | New type excellent | |
12 | Motor damage self-healing function | No | Yes | New type excellent | |
13 | Automatically adjust the mot speed when voltage waving | Constant speed | Slow speed when samll wave; while fast speed when big wave.To protection the motor life span. | New type excellent | |
14 | Motor adjustment strength | Constant | Pulse power | New type excellent | |
15 | Overload protection | Adopt the circuit over-current protection, normal protection | Adopt circuit+over-current+Electronic over-current protection,100% accurately | New type excellent | |
16 | Temperature cotrol | No | Temperature rising can be controlled(the cooling fan working when arrived temperatuare rise point) | New type excellent | |
17 | Temperature protection | No | Cut the output if temperature too high | New type excellent | |
Indication similarities | 18 | Input voltage indicator | YES | YES | |
19 | Output votlage indicator | YES | YES | ||
24 | Overload indicator | YES | YES | ||
25 | Undervoltage indicator | YEs | YES | ||
Indication differences | 20 | Output current indicator | NO | YES | New type excellent |
21 | Output power indicator | NO | YES | New type excellent | |
22 | 100% loading display | NO | YES | New type excellent | |
23 | Temperatura indicator | NO | YES | New type excellent | |
26 | Delay countdown counter | NO | YES | New type excellent | |
27 | Overload indiator | NO | YES | New type excellent | |
28 | Protection method indication | Output Cut (over voltage dangerous) | Input Cut (over voltage safe) | New type excellent |
The new type 10000VA output power performance | |||||
Input voltage V | Input current A | Input power VA | Output voltage V | Output power VA | Output current A |
40 | 46 | 1820 | 120 | 2730 | 23 |
60 | 46 | 2730 | 120 | 4095 | 34 |
80 | 46 | 3640 | 120 | 5460 | 46 |
100 | 46 | 4550 | 120 | 6825 | 57 |
120 | 46 | 5460 | 120 | 8190 | 68 |
140 | 46 | 6370 | 120 | 9500 | 79 |
160 | 46 | 7280 | 120 | 9500 | 79 |
180 | 46 | 8190 | 120 | 9500 | 79 |
200 | 46 | 9100 | 120 | 9500 | 79 |
220 | 46 | 10010 | 120 | 9500 | 79 |
250 | 46 | 10000 | 120 | 9500 | 79 |
Item | Single phase | Three phase | ||
SVC(TND/TNS) | Normal type | 0.5kva,1kva,1.5kva,2k,3kva,5kva, 15kva,20kva, 30kva, 45kva, 60kva, 90kva | SVC(TNS) | 1.5kva,3kva,4.5kva, 6kva,9kva,15kva,20kva, 30kva, 45kva, 60kva, 90kva |
ultra-thin | 5.5kva, 1kva, 1.5kva, 2kva, 3kva, 5kva , 10kva | |||
Input Voltage | single phase 140-260v; ultra-low 90-250V; | 3 phase voltage 140-260v, wire voltage 260-440 140-260v; ultra-low phase voltage 90-250v, wire voltage: 220-430v | ||
Output Voltage | single phase 220v-110v | 3 phase voltage 220v; wire votlage 380v | ||
Over-voltage protection | 246V±4% | phase voltage 246V±4%; | ||
Under-voltage protection | 184V±4% | phase voltage 184V±4% | ||
No setting in normal, can be customized. | ||||
Voltage Regulated Accuracy | ≤±4% | |||
Frequency | 50Hz/60Hz | |||
Waveform Distortion | No additional distortion | |||
Loading power factor | 0.8 | |||
Efficiency | more than 95% | |||
Adjusting time | less than 1 second (the input votlage changed 10%) | |||
Prolong time | long delay: 5±2 mins; short delay: 5±2 seconds | |||
No setting in normal, can be customized. | ||||
Electric appliance | 1500v/min no flashing nor puncture | |||
Insulation resistance | ≥2M Ohm |
Send your inquiry to this supplier