Strong anti-interference performance control device
Strong anti-interference performance control device
Strong anti-interference performance control device
Strong anti-interference performance control device
Strong anti-interference performance control device
Strong anti-interference performance control device
Strong anti-interference performance control device
Strong anti-interference performance control device
Strong anti-interference performance control device

1 / 7

Strong anti-interference performance control device

  • $777.00

    ≥1 Piece/Pieces

Options:

  • AM5SE
Send Inquiry
Model No. : AM5SE
Brand Name : Acrel
place of origin : China
use : Magnetic Sensor,Consumption Sensor
Output : Analog Sensor,Digital Sensor
Amplifier type : Standard
jack : Digital
Usage: : General Purpose
Contact Load: : Low Power
Voltage Input: : AC100V/100/0.3V
Accuracy: : ±0.5%
Rated frequency: : 50Hz
Frequency Accuracy: : ±0.1Hz
Theory: : Voltage Relay
Protect Feature: : Sealed
Power Supply: : AC220V/DC220V,DC110V,DC48V
Voltage Range: : 1-120V
More
3yrs

Wuxi, Jiangsu, China

Visit The Store
  • Platform Certification
  • SGS Certification
  • Online Expo

Product description

General
AM5 series microcomputer protection device are applicable to the user substation which the input voltage is 35kv or above. AM5 can be used to protect and control the user substation, and is be widely used to Power Industry, Water conservancy industry, Traffic Industry, Oil industry, Chemical industry,Coal Industry, Metallurgical Industry and so on.
Technical Datasheet


Rated Input
Range
Accuracy
Power Consumption
Power Supply
AC220V/DC220V DC110V,DC48V
Rated inputx(1±20)
------
≤10W(DC)
Voltage Input
AC100V/100/0.3V
1~120V
±0.5%
≤0.5VA single phase
Frequency
50Hz
45-55Hz
±0.1Hz
-------
DI
AC220V/DC220V DC110V,DC48V
Rated inputx(1±20)
-------
≤1W(DC220) Single DI

Function

Strong anti-interference performance control device

Dimension

Strong anti-interference performance device

Connection

measurement and control device

Wiring

5A zero sequence current device


FAQ
Q: How to set the CT and PT ratio of the protection device?

A:The protection device can set the CT and PT ratio through the fixed value menu. For example, the current transformer is 75/5 and the voltage transformer is 10/0.1, then the CT ratio is set to 15 and the PT ratio is set to 100.

Q: For AM4, if you want to place a circuit line protection and transformer protection, how to distinguish the model?

A: AM4 is suitable for circuit protection and transformer protection. No need to distinguish between models when placing orders

Q: When the voltage is three-phase three-wire system, does the current have to be connected with 2CT?

A: The voltage wiring mode and current wiring mode of the protection device can be set independently, and can be connected freely.

Q: How to confirm whether the anti-trip function is configured?


A: If the circuit breaker is equipped with anti-trip, the device does not must be equipped with anti-trip; if the circuit
breaker does not have anti-trip, you need to configure the AM5-FT anti-trip module. (If DC48V is selected as the
operating power supply, the anti-trip box is not optional, and the circuit breaker must be equipped with anti-trip
function; if you choose AC anti-trip, please note that AC and DC general anti-tripping)

Q: How to purchase suitable protection devices?

A: Before ordering, it is recommended to consult related engineers, select the appropriate protection model,
and then fill in the corresponding selection table, and place the order after confirmation by the engineers.



Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628