Residual Current Circuit Breaker Rccb B-Type 40a-300ma
Residual Current Circuit Breaker Rccb B-Type 40a-300ma
Residual Current Circuit Breaker Rccb B-Type 40a-300ma
Residual Current Circuit Breaker Rccb B-Type 40a-300ma
Residual Current Circuit Breaker Rccb B-Type 40a-300ma
Residual Current Circuit Breaker Rccb B-Type 40a-300ma

1 / 4

Residual Current Circuit Breaker Rccb B-Type 40a-300ma

  • $1.00

    ≥1 Box

Send Inquiry
Model No. : KNL5-63 Type B
Brand Name : Korlen
Breaking Capacity : Low Voltage Circuit Breakers
Operation : Manual Type
Speed : Normal Type Circuit Breaker
Arc-extinguishing Medium : Air
Installation : Fixed
Structure : Elcb
Poles Number : 4
Type : Circuit Breaker
Function : Rccb
Certification : Iso9001-2000
Frame : 63a
Rated Working Voltage : 240v/415v
Rated Worling Current : 16;20;25;32;40;50;63a
Rated Limiting Short-circuit Current : 6000a
Sensibility : B Type
More
7yrs

Wenzhou, Zhejiang, China

Visit The Store
  • Platform Certification
  • Video

Product description

KNL5 series Residual current circuit breaker (without over-current protection) 

is suitable for the line of A,S  and B  50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power rapidly to protect human safety and prevent the accident due to the current leakage. It can be used as infrequent changeover of the line in normal situation. It is applicable to industrial site, commercial site, tall building and civil house.
It complies with standard of IEC/EN61008.1 and GB16916.1.

Residual Current Circuit Breaker
Ac Residual Current Circuit Breaker
Miniature Residual Current Circuit Breaker
Residual Current Electrical Circuit Breaker

Each phase of conductor at the circuit breaker passes through the zero-sequence current transformer, and the secondary side of coil connects with the electromagnetic tripper. Under normal condition, the vector sum of each phase of current passing through zero-sequence current transformer is zero. The flux of the zero-sequence current transformer is zero. And the secondary output voltage is zero and the circuit breaker doesn't zero, and the zero-sequence current transformer would produce the magnetic flux, and the secondary side of coil would output the voltage. Once the leak current increases to drive the output voltage at the secondary side to grow to certain level, the electromagnetic release would activate to drive the operation mechanism to act to break the contact that connects the power, finally to realize the leak protection.

Frame class 63
Rated working voltage 240/415V
Rated frequency 50/60Hz
Rated working current 16,20,25,40,50,63A
Rated residual operating current 0.03,0.1,0.3,0.5A
Rated residual un-operating current 0.015,0.05,0.15,0.25A
Sensibility A Type,AC Type,S Type,B Type
Maximum operating time IΔn t≤0.1s , 5IΔn t≤0.04
Rated making and breaking capacity In≤50A 500A,In=63A 630A , In>63A 1500A
Limiting value of un-operating current 6In
Rated limiting short-circuit current 6000A
Pole number 2,4P
Mechanical life 10000
Electric life 4000