1 / 2
Product description
IP67 / IP68 Outdoor Waterproof Driver Power Supply For Led Bulbs / Tube /Strip Lights
Description:
Applications:
IP67/IP68 waterproof power supplies as the same functions of led driver/led power/led power driver, used in led lamp, led rights, led right bulbs, RGB led rights, led strip lights.
It can be used for LED light strip, swimming poor, outdoorlight, fountain poor, Outdoor advertisement.
Specifications:
SPECIFICATION |
|||||||
MODEL |
LJF-84W-5 |
LJF-84W-12 |
LJF-84W-15 |
LJF-84W-24 |
LJF-84W-36 |
LJF-84W-48 |
|
OUTPUT |
DC VOLTAGE |
5V |
12V |
15 |
24V |
36V |
48V |
RATED CURRENT |
12A |
7A |
5.6A |
3.5A |
2.4A |
1.75A |
|
CURRENT RANGE |
0-8A |
0-7A |
0-5.6A |
0-3.5A |
0-2.4A |
0-1.75A |
|
RATED POWER |
84W |
84W |
84W |
84W |
84W |
80W |
|
RIPPLE & NOISE (max.) Note.2 |
80mVp-p |
180mVp-p |
180mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
|
VOLTAGE TOLERANCE Note.3 |
+/-8% |
+/-5% |
|||||
LINE REGULATION |
+/-1.0% |
||||||
LOAD REGULATION |
+/-4.0% |
||||||
SETUP, RISE TIME Note.6 |
2000ms, 25ms / 230VAC 2000ms, 25ms / 115VAC |
||||||
HOLD UP TIME |
50ms/230VAC 14ms/115VAC at full load |
||||||
INPUT |
VOLTAGE RANGE Note.4 |
90 ~ 264VAC 127 ~ 370VDC |
|||||
FREQUENCY RANGE |
47-63Hz |
||||||
EFFICIENCY (Typ.) |
80% 75% |
85% |
87% |
88% |
88% |
89% |
|
AC CURRENT |
2.1A/115VAC 1.1A/230VAC |
||||||
INRUSH CURRENT (max.) |
COLD START 30A/115VAC 75A/230VAC |
||||||
LEAKAGE CURRENT |
0.25mA / 240VAC |
||||||
PROTECTION |
OVER LOAD |
110-150%rated output power |
|||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
|||||||
OVER VOLTAGE |
5.75 ~ 6.75V |
13.8 ~ 16.2V |
17.25 ~ 20.25V |
27.6 ~ 32.4V |
41.4 ~ 48.6V |
55.2 ~ 64.8V |
|
Protection type : Shut down o/p voltage, re-power on to recover |
|||||||
ENVIRONMENT |
WORKING TEMP. |
-30 ~ +70 (Refer to "Derating Curve") |
|||||
WORKING HUMIDITY |
80-95% RH |
||||||
STORAGETEMP., MIDITY |
-40-+80℃, 10-95% RH |
||||||
TEMP. COEFFICIENT |
+/-0.03%/(0-50℃) |
||||||
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, period for 80min. each along X, Y, Z axes |
||||||
SAFETY &EMC |
SAFETY STANDARDS |
UL879, UL8750, UL1310 Class 2, TUV EN61347-1, EN61347-2-13 independent, CAN/CSA C22.2 No. 223-M91(except for 48V) ; J61347-1, J61347-2-13(option, 80~27only), IP67 approved |
|||||
WITHSTAND VOLTAGE |
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC |
||||||
ISOLATION RESISTANCE |
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH |
||||||
EMC EMISSION |
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3 |
||||||
EMC IMMUNITY |
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, light industry level, criteria A |
||||||
OTHERS |
MTBF |
495.7Khrs min. MIL-HDBK-217F (25 ) |
|||||
DIMENSION |
75*51*28(mm) |
||||||
PACKING |
0.18Kg;80pcs/11.8kg/0.46 CUFT |
||||||
NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. |
||||||
|
|||||||
|
|||||||
|
|||||||
|
|||||||