Intrinsic Isolated Barrier
Intrinsic Isolated Barrier
Intrinsic Isolated Barrier

1 / 1

Intrinsic Isolated Barrier

  • $1000.00

    ≥1 Piece/Pieces

Send Inquiry
Model No. :
Brand Name :
3yrs

Shanghai, Shanghai, China

Visit The Store
  • Platform Certification

Product description

Intrinsic safety barrier instrument and isolators use intrinsically safe explosion-proof and functional safety technologies and adopts various measures such as rapid cut-off, isolation, and energy limiting to ensure that the energy transmitted to the field equipment in the hazardous area is intrinsically safe, thereby preventing dangerous energy from entering the danger zone and causing an explosion. 

An isolation barrier electrical, such as the digital input barrier, is a key interface unit in the intrinsically safe explosion-proof control system. The intrinsically safe barrier or the intrinsic safety barrier with quite affordable intrinsically safe barrier price made by CHENZHU, one of the top intrinsic safety barrier manufacturers in China, is made under a strict production process and tested by a series of quality assurance systems.

IS Barrier Types

GS8500-EX Series Intrinsic Safety Barrier
GS8500-EX range functional intrinsic safety barriers and isolators are CHENZHU's hit products, which obtained the first IECEx、ATEX、DE TUV SIL、JP TIIS certifications in domestic China, offering the widest selection of products for protection of electrical signals, meets the intrinsic safety standards for both explosive gas and dust environment, widely used in control system of petroleum and petrochemical, railways, coal mines and other industries.
GS8500-EX Analogue Intrinsic Safety Barrier
GS8500-EX Analogue Intrinsic Safety Barrier Loop Power
GS8500-EX Digital Intrinsic Safety Barrier
GS8500-EX Digital Intrinsic Safety Barrier Loop Power
GS8500-EX Temperature Converter Intrinsic Safety Barrier
GS8500-EX Voltage Input Intrinsic Safety Barrier
GS8500-EX Communication Input Intrinsic Safety Barrier
GS8500-EX Frequency Converter Intrinsic Safety Barrier

GS5000-EX Series Intrinsic Safety Barrier
GS5000-EX range classic intrinsic galvanic isolation barriers apply precision electrical signal detection and galvanic isolation transmission technology, combined with reliable immunity and intrinsic safe circuit design, to achieve stable and reliable transmission of intrinsically safe explosion-proof circuit signals.
GS5000-EX Analogue Intrinsic Safety Barrier
GS5000-EX Analogue Intrinsic Safety Barrier Loop Power
GS5000-EX Digital Intrinsic Safety Barrier
GS5000-EX Digital Intrinsic Safety Barrier Loop Power
GS5000-EX Temperature Converter Intrinsic Safety Barrier

GS8200-EX Series Intrinsic Safety Barrier
GS8200-EX range isolated barriers are Chenzhu's featured products. The isolated barriers can measure and transmit analog (4~20mA) signals or temperature sensor signals. The isolated barrier could monitor whether the input signal is abnormal and output in the way of relay contact.
GS8200-EX Analogue To RS485 Intrinsic Safety Barrier
GS8200-EX Temperature To RS485 Intrinsic Safety Barrier

LBGS8000-EX Series Surge Protective Intrinsic Safety Barrier
LBGS8000-EX range surge protective isolated barriers are Chenzhu's unique products, which include digital input, digital output, analog converters, analog input, analog output, temperature converters, and communication input.

GS4000-EX Series Backplane Intrinsic Safety Barrier
GS4000-EX range of backplane mounting intrinsic safety barrier provides an innovative solution for protecting electrical signal. The intrinsically safe barrier connected to the socket on the bottom plate through the plug at the bottom of the isolation barrier, and then connected to the I/O card through the customized socket and prefabricated cable on the bottom plate.
What is Difference Between Intrinsic Isolated Barrier and Isolator?
Isolator
The isolator is used to adjust, isolate and transform all kinds of field instrument signals into the normal signals or special signals specified by users which can be accepted by the computer, DCS, PLS, etc. It is also used to isolate control equipment and operational equipment from electronics, like a relay.

Intrinsic isolated barrier
The isolated barriers in our safety automation system for sale are associated equipments of explosion-proof instruments that will not affect the function of the measurement system in a normal situation. The isolated barrier is placed on one side of the security site, when the explosion-proof system fails, the intrinsic barrier can limit the energy(electric energy) which can enter the dangerous site to safe values to ensure the safety of the scene.

Difference
1.Different feature. Barrier: High reliability and precision, strong EMC performance. Isolator: Gives electrical isolation among the input & output circuits.

2.Different function. Barrier: Protect electrical signals in potentially flammable or other hazardous areas. Isolator: Adjust, isolate and transform all kinds of field instrument signals into the normal signals or special signals specified by users.

3.Main difference: Explosion proof or not.

What is Safety Level of Intrinsically Safe Electrical Equipment?
IA
IA means that the explosive gas mixture cannot be ignited under normal operation, one counting failure, and two counting failures. IA-level intrinsically safe electrical equipment can be used in hazardous locations in Zone 0, Zone 1, and Zone 2.

IB
IB means that explosive gas mixtures cannot be ignited under normal operation and a counting failure. IB's intrinsically safe electrical equipment that can be used in hazardous locations in Zone 1 and Zone 2.

IC
IC means that explosive gas mixtures cannot be ignited under normal operation. IC-level intrinsically safe electrical equipment can be used in zone 2 hazardous locations.

FAQ of Intrinsic Isolated Barrier
When and why is intrinsic safety certification required?-
When the equipment is installed in an area where combustible materials exist, measures must be taken to minimize the risk of fire. Intrinsic safety barriers are considered a suitable approach, although the entire system needs to be designed accordingly. An IS will make your manufacturing safer.

Do intrinsically isolated barriers replace explosion proofing or pressurization?-
No, due to the dependence on low power and low temperature, the intrinsic safety equipment cannot replace these methods in all applications. However, using intrinsically safe electrical equipment will usually greatly save installation and maintenance costs.

Do intrinsically safety barriers affect the performance of the certified device?-
No, when the intrinsic safety barrier is used, the performance of power equipment is more reliable than when it is not used. The isolation barrier is designed to limit the energy stored and heat generated in the event of an internal failure.

What is intrinsic isolated barrier?-
Intrinsically safe electrical equipment is designed to limit the dangerous energy of the safe place into the dangerous place, that limit the voltage and current sent to the hazardous place—only stops dangerous levels of voltage and current, not stop signals or communication getting through.

Compare to the Nomar isolated barrier, the intrinsic isolated barrier is more advantageous.

As one of the intrinsic safety barrier manufacturers, Chenzhu has developed mature safety and automation system and can provide intrinsic isolated barriers with high reliability, high EMC performance and high safety.

What are the precautions for the use of isolated barriers?-
1. Isolated barriers should be installed in a safe-area.

2. Isolated barrier can only be connected with IS apparatus(including simple apparatus) to form an IS system.

3. Isolated barrier is not possible to link non-IS instruments form an IS system.

Is intrinsic safety equipment more expensive than non-certified versions?-
Generally, devices with intrinsic safety certification are slightly more expensive than non essential versions. Because obtaining and maintaining intrinsically safe certification requires additional costs. In fact, the basic design of is barrier uses zener diode to limit voltage, resistor to limit current and fuse, which are not expensive.

What are the benefits of intrinsic safe barriers?-
When electrical equipment and instruments are installed in hazardous environments, intrinsic safety barriers need to be used. The main advantages are as follows: 1. The intrinsic safety barrier helps ensure a safe working environment and protects nearby people from the risk of explosion. 2. The intrinsically safe barrier avoids the cost and volume of an explosion-proof enclosure. 3. The risk of working environment is reduced. Maintenance and diagnosis can be carried out without closing the ventilation of the production and working area, so the insurance premium may also be reduced.

If you want to know more about what is isolation barrier, please visit our website.

Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628