IEC62271 - 100 Rated Insulating Level 42 / 75 kV 12kv VMD2 Indoor Vacuum Circuit Breaker

Technical Parameters

NO

Item

Unit

Technical Date

1

Rated voltage 

kV

12

2

Rated insulating level

Rated short time power 

frequency withstand voltage

(1min)          

42

Raed lighting inpulse

 withstand voltage 

(peak value)              

75

3

Rated Frequency

Hz

50

4

Rated current 

A

630

630

1250

1250

1250

1250

1600

1600

 

 

2000

2000

2500

2500

3150

3150

4000

4000

5

Rated short circuit

 breaking current        

kA

20

25

31.5

40

6

Rated short time withstand current           

20

25

31.5

40

7

Rated peak withstand current  

50

63

80

100

8

Rated short-circuit 

closing current (peak value)

50

63

80

100

9

4S rated short-time 

withstand current  4s 

20

25

31.5

40

10

Rated shock steady current 

50

63

80

100

11

Rated making surge current of 

capacitor bank

12.5(The frequency is 

less than 1000Hz)

12

Rated breaking current of single/

symmetrical capacitor bank 

A

630/400 (The value shoule

 be 800/400 while the current is 40kA)

13

Duration of rated short-circuit current

S

4

14

Power frequency withstand voltage 

of secondary circuit

V

2000

15

Rated operationl voltage

Making coil

AC110/220   DC110/220

Breaking coil

AC110/220   DC110/220

Energy-storage motor 

AC110/220   DC110/220

16

Making time  (under Rated voltage)

ms

35-70

17

Brealing time(under Rated voltage)

20-45

18

Permitted abrasion thickness of

 moving and fixed contacts 

mm

3

19

Energy storage times 

S

≤15

20

Contactor space

mm

9± 1

21

Contacting travel 

3---4

22

Bounce time of Contactor during making 

ms

≤2

23

Different time of breaking / making of 3 phases 

≤2

24

Average breaking speed 

0.9-1.3

25

Average making speed 

0.4-0.8

26

Rebound amplitude of contact breaking

mm

≤3

27

Conductance circuit resistance 

µΩ

≤50 (630A)

≤45(1250A)

≤35(1600A-2000A)

≤25(More than 2500A) 

28

The contacting pressure of of

 contactor during making

N

2000±200(20kA)

2400±200(35kA)

3100±200(31.5kA)

4750±250(40kA)

29

Rated operating sequence

 

O- θ -CO-180s-CO

The average breaking speed is that of contactor’s first 6mm . 

The average making speed refers to the average speed of total Contactor space .

When the rated short circuit breaking current is less than 40kA,  θ is equal to 0.3S. 

When the short circuit breaking current is more than or equal to  40kA,  θ is equal to 180S

 

 

Outline Dimension Drawing

Dear friends,  pls contact us for the outline dimension drawing, we will give you quick reply.

Summary

The VMD2 series indoor circuit-breaker is our independent developed new generation 12 kv vacuuum circuit breaker. 

Its main characters as follows:

 the conductance circuit is installed in an three-phase insulating sleeve ,

 its mechanism and conductance circuit adopts front and rear layout. And the mechanism 

is our deveoped new design,  

with simple construction,  reliable operation, and rich manufacturing experiences of million sets ,  

used  and learned by many high-end vacuum circuit breaker manufacturers.

 

Technical standard

All the technical parameters of breaker completely satisfy the Standards Of GB1984 

AC Highvoltage Breaker,

 GB/T 11022 -1999 Common Specifications For High-Voltage Switchgear And Controlgear Standards,  

China Power Sector Standards DL403.

Also meet the requirements of IEC62271-100,  IEC56 and other main industrialized country’s similar standards

 

Testing

VMD2 series circuit breaker have passed has passed following 

test ,  to ensure the product’s safe Operation.

 

Type tests : power-frequency withstand voltage tests ,  lighting impact withstand voltage tests,  ,  temperature rising tests,  

short-time withstand current tests ,  peak withstand current tests , short circuit breaking ability tests ,  mechanical lift tests, ect

 

Routine test before out of factory: mechanical performance test  ,  power-frequency withstand voltage tests of the main circuit ,  insulating property  tests on control and auxiliary circuits ,

measurement of ther resistance of the main circuit ,  interlock operating tests ,  mechanical operating tests,

 Electrical Equipment operating tests.

 

Scope of application

 

 

It is universally used in power plant ,  electric network ,  metallurgy industry petrochemical industry and infrastructures,

such as airport ,  subway,  building.

VMD2 circuit breaker can be applied to control and protect cable ,  trolly wire , transformer,  g

enerator and capacitor bank in distribution system

 

Safety

VMD2  circuit breaker possesses  perfect mechanical and electric interlock equipment ,  meanwhile ,

its high reliable operating performance and mechanical life ,  coodinated with matched switchgear cabinet ,

to ensure normal power distribution ,  operator and equipment’s safety.

 More Information,Please See Our Official Website: www.meletek.com 