Closed loop DC leakage current sensor
Closed loop DC leakage current sensor
Closed loop DC leakage current sensor

1 / 1

Closed loop DC leakage current sensor

Get Latest Price

Options:

  • THB_LTB15D_H
Send Inquiry
Model No. : THD_E4T15D5
Brand Name :
place of origin : China
use : Electronic
Coil structure : Toroidal
More
2yrs

Zibo, Shandong, China

Visit The Store
  • Gold Supplier
  • Platform Certification

Product description

Product introduction

Application

Ø Power supply: ± 12V ~ ± 15V DC

Ø Fluxgate principle - DC leakage current sensor;

Ø The primary and secondary of the current sensor are insulated and can measure weak DC signals;

Ø Signal system

Ø Current difference detection

Ø current detection of elevator

Ø Leakage detection of DC screen

                 Electrical characteristics

Parameter

Symbol

THD10

E4T15D5

THD20

E4T15D5

THD30

E4T15D5

THD40

E4T15D5

THD50

E4T15D5

THD100

E4T15D5

 

Rated current

IPN(A)

10

20

30

40

50

100

 

Measuring range

IP(A)

0~±14

0~±28

0~±42

0~±56

0~±70

0~±140

 

Output voltage

VO(V)

±5.0*(IP/IPN),DC

Load resistance

RL(k)

10

Working power supply

VC(V)

±12V~±15V DC±5%

Insulation voltage

VD(V)

50/60Hz1min3kVRMS

                 General parameters

Project

Condition

Date

Unit

Accuracy XG

@ IPN,T=25

<±1.0

%

Zero offset voltage VOE

@ IP=0,T=25

<±50

mV

Current offset temperature drift VOT

@ IP=0,-40+85

<±2.0

mV/

Hysteresis offset voltage VOH

@ IP=0,after 1*IPN

<±25

mV

Linearity εr

1.0

%FS

Response time tra

@ 90% of IPN

<200

ms

Operating bandwidth BW

-3dB

DC-20

kHZ

Working temperature TA

-10+70

Storage temperature TS

-25+70

Static power consumption IC

10+Is

mA

Product weight m

220

g

Shell material

PBT material containing 30% glass fiberFlame retardant gradeUL94- V0;

Standard

IEC60950-1:2001    EN50178:1998    SJ20790-2000

                 Structural drawing: (mm)

Thd E4t15d5 2d

                 Connection diagram:

THD_E4T15D5 J

Remarks:

1. When the measured current passes through the primary pin of the sensor, there is a corresponding voltage signal output at the output end;(Note: wrong wiring may damage the sensor)

2. Products with different rated current can be designed according to the requirements of customers, and the output voltage of the sensor can be selected;

3. When the busbar is fully filled with holes, the dynamic performance is the best;

4. The temperature of primary conductor shall not exceed 100;



Send Inquiry