1 / 4
Model No. : | LPV-30-12 12v waterproof power supply |
---|---|
Brand Name : | Winston/OEM |
Product description
Features: |
Protections:Short circuit/Overload |
Damp/wet location outdoor application. |
100% full-load burn-in test |
2 year warranty |
model | LPV-30-5 | LPV-30-12 | LPV-30-24 | LPV-30-36 | |
output | DC voltage | 5V | 12V | 24V | 36V |
max rated current | 6A | 2.5A | 1.3A | 0.8A | |
current range | 0 ~6A | 0 ~2.5A | 0 ~1.3A | 0 ~0.8A | |
max rated power watts | 30W | 30W | 31W | 29W | |
ripple &noise (max.) Note.2 | 100mVp-p | 100mVp-p | 100mVp-p | 1500mVp-p | |
setup,rise,hold-on time | 800ms, 20ms ,24ms/230VAC | ||||
input | input voltage range | 90 ~ 132VAC or 180 ~ 264VAC 254 ~ 370VDC | |||
input frequency range | 47 ~ 63Hz | ||||
frequency (Typ.) | 78% | 78% | 80% | 82% | |
input current | 0.42A/230VAC | ||||
inrush current(max.) | 30A/230VAC | ||||
leakage current | <0.5mA / 240VAC | ||||
protections | over load | 105 ~ 150% of rated output power watts | |||
protection type :hiccup mode,recovers automatically after fault condition is removed | |||||
ENVIRONMENT | working temp. | -10 ~ +60 °C(Refer to output load derating curve) | |||
working humidity | 20 ~ 90% RH non-condensing | ||||
storage temp,humidity | -20 ~ +85°C , 10 ~ 95% RH | ||||
temp.coefficient | ±0.03%/ °C(0 ~ 50°C ) | ||||
vibration | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||
safety & EMC | safety standards | Design refer to UL 1012 | |||
withstand voltage | I/P-O/P:2KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
isolation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | ||||
EMI CONDUCTION & RADIATION | Design refer to EN55022 Conduction Class A | ||||
others | protection level | IP67 | |||
MTBF | 200K hrs min. MIL-HDBK-217F (25°C ) | ||||
dimension | 222*30*20mm (L*W*H) | ||||
packing | 0.25KG/80PCS/21KGS | ||||
Notes | 1. All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25°C of ambient temperature | ||||
2.Ripple&noise are measured at 20MHz of bankwidth by using 12" twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor | |||||
3.Tolerance:includes set up tolerance,line regulation and load regulation | |||||
4. This power supply as a device installed to a final device,the final device must be reaffirm it's EMC indicator. |
Send your inquiry to this supplier