1 / 3
Model No. : | SP300VAC2000W |
---|---|
Brand Name : | APM |
Dongguan, Guangdong, China
Product description
Chose APM AC power sources to meet your basic AC power needs with stable, reliable power.This adjustable ac dc power supply offers intuitive user interfaces that make it easy for engineers to access and view setup and measurement information directly from the front panel or programmatically via SCPI (Standard Commands for Programmable Instruments) commands. Covering 24 volt power supply to offer better experience for customers.
Application Area:
This series is applicable to multiple sectors such as electric, lighting and aviation sectors and it could be applied to enterprise's production test as well.
Product Features:
● 5.6" large touch color screen, possess complete functions and easy to operate.
● Support for USB data import/export and screen snap from front panel.
● AC+DC mixed or independent output mode for voltage DC offset simulation.
● Capable of setting voltage and current output restriction, support for constant current output mode.
● Capable of setting output slope of voltage and frequency.
● Capable of setting ON/OFF phase angle.
● Support for LIST/PULSE/STEP mode, simple time setting and circulation setting, which is suitable for power line disturbance simulation test.
● Built-in power sweeping function.
● Built-in Transient mode.
● Built-in Dimmer function.
● With reverse current protection to avoid current flowing backward.
● Built-in power meter, which is capable of measuring 15 electrical parameters, including voltage, current, frequency, etc.
● Support mA current measurement function.
● Built-in IEC61000-3-3/ IEC61000-3-2/ IEC61000-4-11/ IEC61000-4-14/ IEC61000-4-28/ IEC61000-4-13 standard test required waveform.
● Support up to 2 units in series, 4 units in parallel and 3 units combined to 3-phase power output (optional).
Basic Functions:
1. Adjustable Phase Angle/Slope
Adjustable Phase Angle/Slope is applicable to verification test of ON/OFF inrush current testing. This function is applicable to start inductive or capacitive load with large capacity to avoid high current when instantaneously start the device.
2. High Output Current Crest Factor
The surge current could reach 5-6 times of the rated current, especially suitable for inrush current testing.
3. Transient mode
Transient mode simulates the impact on test object when turn on or turn off transient high power capacity load in power grid.
4. Dimmer Function
Support Dimmer function, which is applicable to conduct speed regulating or dimming verification test for electric motor, lamp and other products.
5. Output Simulation Sequence and Disturbance Simulation
Capable of simulating power line disturbance simulation test.
Advanced Functions:
1.Output Impedance(Applicable to Professional Version)
Support Simulating Output Impedance.
2.Built-in IEC Standard Test(Applicable to Professional Version)
Built-in IEC standard test could be recalled directly.
3. Amplifier Function
The programmable AC power source could realize real time output by tail after signal waveform.
4. Harmonics/ Inter-harmonics Generate Simulation and Harmonics Measurement(Applicable to Professional Version)
Up to 40 orders of harmonics components, applicable to interference simulation test.
5. External Control Function
Programmable AC power sources could provide analog input under test simulation of PASS, FALL and RUN status and user can control ON/OFF externally, force to shutdown, reset and upload 7 sets of stored parameters.
6. 3-Phase
Operation and Parallel Mode
Support up to 2 units in series, 4 units
in parallel and 3 units combined to 3-phase power output.
Technical Specification:
at
220VAC Input ,
Rise
time/
1Hz at 100~1000Hz,
Output
& Inter-
harmonics
1Hz at 100~1000Hz,
Model
SP300VAC2000W
Advanced
SP300VAC2000W
Professional
INPUT
1
Voltage
190~265VAC
2
Frequency
47~63Hz
3
Phase
1 Phase,
2Wire+Groud
4
Max.
Current
14A
5
Power
Factor
Full Load
≥0.99 Active
PFC
6
Efficiency
>87%
(Peak)
>86% at 220VAC,50Hz input/230VAC,50Hz output, Full
Load
OUTPUT
7
AC
Power
2000VA
8
Max.
Current
(r.m.s)
0~150V(L)
16A
0~300V(H)
8A
9
Max.
Current
(Peak)
0~150V(L)
80A
0~300V(H)
40A
10
Phase
1
Phase
11
Crest
Factor(CF)
≤5
12
Load
Regulation
±0.1%F.S.(Resistive Load) at
15-70Hz
±0.5%F.S.(Resistive Load) at 70.1-1200Hz
Note:1001~1200Hz only
available to Professional Version Models
13
Line
Regulation
±0.1V
14
Voltage(AC)
Range
0~300VAC, 150V/300V/Auto
Mode
Resolution
0.1V
Accuracy
0.2% of setting
+0.2%F.S.
15
Voltage(DC)
Range
0~424VDC
Resolution
0.1V
Accuracy
0.2% of setting
+0.2%F.S.
Max.
Power
2000W
Max. Current
(L/H Range)
L
11.3A
H
5.65A
drop
time
<180us
16
Current OC
Fold
Mode
Resolution
0.01A
Accuracy
0.5% of setting
+1.0%F.S.
Response
Time
<1400ms
17
Frequency
Range
15~1000Hz Full Range
ADJ
15~1200Hz Full Range
ADJ
Resolution
0.1Hz at
15.0~99.9Hz,
1Hz at 100~1000Hz
0.1Hz at 15.0~99.9Hz,
Accuracy
0.03% of
setting
18
Programmable
Range
N/A
0Ω +0mH~1Ω
+1mH
19
Harmonic
Range
N/A
2400Hz
MEASUREMENT
20
Voltage
Range
AC 0~300VAC
DC
0~424VDC
Resolution
0.1V
Accuracy
0.2% of setting
+0.2%F.S.
21
Frequency
Range
15~1000Hz
15~1200Hz
Resolution
0.1Hz at
15.0~99.9Hz,
1Hz at 100~1000Hz
0.1Hz at
15.0~99.9Hz,
Accuracy
0.1% of
setting
22
Current
(r.m.s)
Range
H 0.15A~20A
M -
L 0.1A~5A
mA 0.02A~1.5A
Resolution
0.01A
Accuracy
H/M 0.4%+1.0%F.S.
L/mA
0.4%+1.0%F.S.
23
Current
(Peak)
Range
0A~81.5A
Resolution
0.01A
Accuracy
H/M 0.4%+1.5%F.S.
L/mA
0.4%+1.5%F.S.
24
Power
Range
0~2040W
Resolution
0.1W
Accuracy
0.4% of setting +1.0%F.S.
at PF>0.2, Voltage >5V
25
Harmonic
Range
N/A
2~40
orders
GENERAL
26
Parallel Output for 1
Phase
Yes, 4 Units Max.
(Option: Remote I/O & Parallel, Multiphase Link
Card)
27
Series Output for 1
Phase
Yes, 2 Units Max.
(Option: Remote I/O & Parallel, Multiphase Link
Card)
28
Link Output for 3
Phase
Yes
(Option: Remote I/O &Parallel, Multiphase Link Card)
29
FAN
Temperature
Control
30
Protection
Circuits
OCP, OVP, OPP, OTP, RCP,
PRI_UVP, PRI_OVP, PRI_OTP, PRI_OCP, USB_OCP
31
Interface
USB, RS485,
RS232(Standard); LAN,GPIB (Optional)
ENVIRONMENTAL
32
Operating
Temperature
0°C to
40°C
33
Storage
Temperature
-40°C to
85°C
34
Noise
73dBA(Max fan
speed)
35
Altitude
2000m
36
Relative
Humidity
5%~95%,
non-condensing
37
Temperature
Coefficient
100ppm/°C at Voltage,
300ppm/°C at Current, 100ppm/°C at Frequency
MECHANICAL
38
Dimensions(W*H*D)
483*133*649mm
39
Unit Net
Weight
21.4kg
*Note:The tolerance will
change slightly in high frequency condition.
Dongguan, Guangdong, China
Send your inquiry to this supplier