125A Single Pole MCCB high capacity Icu 25kA
125A Single Pole MCCB high capacity Icu 25kA
125A Single Pole MCCB high capacity Icu 25kA
125A Single Pole MCCB high capacity Icu 25kA
125A Single Pole MCCB high capacity Icu 25kA
125A Single Pole MCCB high capacity Icu 25kA
125A Single Pole MCCB high capacity Icu 25kA
125A Single Pole MCCB high capacity Icu 25kA

Video

1 / 6

125A Single Pole MCCB high capacity Icu 25kA

$4.46 ~ $5.62 / Piece/Pieces
Send Inquiry
Model No. : TRMF2 125A 1P
Brand Name : TRANER
place of origin : China
species : Moulded Case,Air,Magnetic
Number of poles : 1
Origin : China
Installation : Screw Mounting
Transport Package : Cartons
Type : Circuit Breaker
Trademark : TRANER
HS Code : 8536200
Breaking Capacity : Low Voltage Circuit Breakers
Speed : High-Speed Circuit Breaker
Arc-extinguishing Medium : Air
Operation : Thermal Magnetic
Function : Conventional Circuit Breaker, Overcurrent Protection, Over Load Protection and Short Circuit Protection
Structure : MCCB
Model NO. : TRMF2-H1
Poles Number : 1 Pole
More
3yrs

Wenzhou, Zhejiang, China

Visit The Store
  • Gold Supplier
  • Platform Certification

Product description

MCCB TRM SERIES

Standard
TRM series circuit breaker and auxiliaries comply with the following international standard:
1.IEC/EN 60947-1
Low-voltage switchgear and controlgear-part 1: General rules;
2.IEC/EN 60947-2
Low-voltage switchgear and controlgear-part 2: Circuit breakers;

TRM series MCCB(Standard use environment for TRM series MCCB)
1. Ambient temperature: Within the range of -5ºC--+55ºC(However, when the temperature exceed 40ºC,it should be considered to reduce the capacity to use);
2. Relative humidity: Within the range of 45%--85%;
3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered);
4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist;

Classification:
According to the poles:                                          1-pole, 2-poles, 3-poles, 4-poles
According to the breaking capacity:                         S-type, H-type
According to the rated current:                               Fix type, Adjustable type(08In-1.0In)
full series ls design MCCB
mccb
Technical data table: 
Ampere frame size TRMF2(125A)
Breaking capacity code S H
Product code and poles 1P 2P 3P 4P 1P 2P 3P 4P
TRMF2-S1 TRMF2-S2 TRMF2-S3 TRMF2-S4 TRMF2-H1 TRMF2-H2 TRMF2-H3 TRMF2-H4
Rated current, In(A) 15, 20, 30, 40, 50, 60, 75, 80, 100, 125
Adjustable part Rated current setting(0.8In-1.0In) χ χ
Lockup device for operating handle χ χ
Rated operational voltage, Ue(V), AC 50/60 Hz 240/415
Rated insulation voltage, Ui(V) 1000
Rated impulse withstand voltage, Uimp(kV) 8
Standard Conformity with IEC/EN 60947-2
Rated frequency(Hz) 50/60
Rated short-circuit breaking capacity, Icu(kA)
AC 240V 18 35 25 50
415V - 18 - 35
Ics=% * Icu 50% 100% 50% 100%
Mechanical life(circle) 8500
Electrical life(circle) 1500
Dimension:
Length*Width*Height
1-pole 130*25*60
2-poles 130*50*60
3-poles 130*75*60
4-poles 130*100*60

Built-in accessory:
MCCB good LS design
Built-out accessory:
mccb
 

 

 


Company show:
mccbmccbmoulded case circuit breaker
Exhibition:
mccbmccbmccbcompact size MCCB

Video

Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628