Wp Push Terminal(connector,terminal) 1. Standard atmospheric condition
Unless otherwise specified, the standard range of atmospheric conditions for making
measurements and tests are as follows
Ambient temperature15 to 35
Relative humidity 25% to 80%
Air pressure 86kPa to 106kPa
If there is any doubt about the results, measurements shall be made within the following limits
Ambient temperature20 2
Relative humidity 60% to 70%
Air pressure 86kPa to 106kPa
Applicable wire AWG 1624
Operating temperature range1065
Storage temperature range 2075 2. Mechanical characteristics 2.1Operating force Push plate force shall be measured by using a gauge of standard dimensions. 2.2Lead wire hold force This test shall consist of AWG#20 copper wire of deeply inserted operation. 2.3Input hole 2.0 mm MIN. 2.4 Terminal strength A static load of 29.4N3Kgfshall be applied to the terminals for 10 seconds in any direction.The terminal shall not be excessive looseness from the housing.