weifang Diesel Generator Ricardo Generator 60kw chinese manufacturer
weifang Diesel Generator Ricardo Generator 60kw chinese manufacturer
weifang Diesel Generator Ricardo Generator 60kw chinese manufacturer

1 / 1

weifang Diesel Generator Ricardo Generator 60kw chinese manufacturer

Get Latest Price
Send Inquiry
Model No. : HR-8GF--HR-140GF
Brand Name : HIGH TECH
9yrs

Weifang, Shandong, China

Visit The Store

Product description

Specifications 1) diesel power generator set

2)Low fuel consumption

3)8 hours fuel tank

4)Professional test

5)ISO,CE approval

  weifang Diesel Generator Ricardo Generator 60kw chinese manufacturer     2,Data of diesel power generator set Rated power20kw-250kw ModelHT20GF-HT250GFTypeopen type,soundproof,weather proof type, mobile type as your required Rated voltage400/230V,240/120V etc,as required Rated frequency50Hz/60HZ. Rated current36A--4500A Rated speed1500/1800rpm Connection typesingle phase or 3P4W Voltage governorAVR Start methodelectric start 3.The data of engine for diesel power generator set   BrandRicardo  Model2100D Number of Cylinders2 in line Rotating Speed1500/1800RPM Cycle4 stroke Type Direct Injection Bore×Stroke(mm)100*115 Displacement(L)1.8 Lubricating Capacity(L)6.5 Speed GovernorElectrical  Cooling SystemWater-cooled Speed Stability (%)≤5% Fuel Consumption at 100% Load208g/kw.h Starting MethodElectrical starting 4,Brushless alternator Specification of  diesel power generator set Alternator Brand                   Stamford,Engga,Mecc-alte,Marathon ...
Exciter Type                            Brushless, Self-excited
Rated Speed                        1500/1800rpm
Rated Frequency                  50/60hz
Phase                                    three or single
Rated Voltage                      400V (Available with customer requirements)
Power                                     0.8
Voltage Adjust Range          ≥5%
Protection Grade                   IP23
Insulation Grade                    H Compliance with GB755,BS5000,VDE0530,NEMA MG1-22,IEC-34,CSA C22-100and AS1359 standards 5,Digital Control System of diesel power generator set 1)Control box with Ammeter,Voltmeter,Frequency Meter,Water temperature,Oil Pressure ,Hour counter,Phase TransferSwitch, CircuiBreaker,Indicator Light for power, generating & emergency. protection system with module for over speed,high temperature,low oli pressure. 2)LED contorl panel   6. Accessories of diesel power generator set    1) Standard accessories: Standard 40 radiator mounted on skid, Common steel frame, circuit breaker, damper, exhaust silencer, flexible pipe, battery and connecting wires, Standard tools kit, operation manual and document.
2) Optional accessories: Engine coolant and oil heater, alternator space heater, cooling for heat exchanger, communication interface, battery charger by main supply, daily fuel tank, ATS and paralleling system, soundproof canopy and moving trailer.   7.Standard configuration of diesel power generator set     1) Starting system: DC alternator is used to start engine 2) Short circuit protection: MCCB air switch 3) Cooling system: combined cooling water tank fitted to meet the requirement of radiation at ambient temperature 40°C 4) Filter system: oil, fuel and air filter   8.Optional type for diesel power generator set   9.Other generators in our factory in addition to diesel power generator set    10.Warranty of diesel power generator set   12 months or 1500 running hours from shipment date. If the quality problem arise during the warranty period,and verified the problem is caused by our genset body instead of external or natural reasons. (Refer to all kinds of natural disaster, shipping, loading, unloading, wrong operation, etc), we will supply the relevant spare parts free of charge for maintenance; after the warranty period, we can supply the required spare parts for you under cost prices   10.Our partners of diesel power generator set   Our advantage:   Use Manual:   1. Operators need to be familiar with the operation of generating sets, operating methods, and all control bodies, manual valves, stopping body position.   2. In the engine room or near the unit, must hoisting of danger notices warning signs associated personnel:   (1) Units exist electric shocks danger;   (2) Units exist scald danger;   (3)Units exist winding, and collision dangers;   3.To avoid fuel, lubricants, and other fire, engine room No smoking.   4. Engine room or other nearest should maintain an appropriate level of fire service equipment (proposed CO2 fire extinguishers). 5. Grounding the entire unit reliably, and meet the applicable requirements of neutral grounding.   6. Above and around the unit should not be unrelated equipment, obstructions and dangerous goods, should be keeping the floor dry and clean without oil.   7. Units will be run by noise, suggest that the staff wear suitable protective equipment, such as earmuffs vehicles.   8.Before any maintenance, must cut off all power lines, particularly the Dc power supply circuit (remove the battery’s anode and cathode), the warning signs must also note “is maintenance“, and should have another concern, especially in the narrow region maintenance at the same time should be notified stop all of this unit operation.   9. To the reliable operation of unit, the settings of unit voltage, frequency, speed and other related parameters and unit controller set up should not be arbitrarily changed except the specialized operators.   10. Units are valuable equipment, for personal safety, operation stability to light, no illegal operation and drink operation.