1 / 6
Model No. : | WDW |
---|---|
Brand Name : | LSD-LuDa universal testing machine |
Product description
The testing machine adopts AC servo motor as a power source; by adopting the chip integration of advanced technology, amplification of PCI data acquisition and control system of professional design,test force,deformation of the amplification, A/D conversion process to achieve the full digital adjustment. This machine can test and analysis of mechanical properties of various metals, nonmetals and composites, are widely used in aerospace, petrochemical, machinery manufacturing, electric wire, cable, fiber, textile, plastics, rubber, ceramics, food, pharmaceutical packing, plastic pipe, plastic doors and windows, geotextile, film, wood,paper, metal materials and manufacturing, according to GB, JIS, ASTM, DIN, ISO and other standard automatic calculating the maximum test force value, breaking force value,yield strength, upper and lower yield strength, tensile strength, compressive strength,elongation, tensile modulus, flexural elastic modulus test data. |
Model specification | WDW-10 | WDW-20 | WDW-50 | WDW-100 | WDW- 200 | WDW-300 | WDW-500 | WDW-600 |
Maximum test force (kN) | 10 | 20 | 50 | 100 | 200 | 300 | 500 | 600 |
Level of testing machine | Level 1 (Level 0.5) | |||||||
Operation mode | Computer control | |||||||
Effective measurement range | 2%-100% (0.4%-100%) | |||||||
Load indication accuracy | Better than ±1% (±0.5% Special selection) | |||||||
Transfiguration display error | ±1% (or ±0.5%) | |||||||
Minimum resolution test force | 0.01N | |||||||
Beam displacement precision | ±1% (±0.5%) | |||||||
Deformation accuracy | Better than ±1% (±0.5%) | |||||||
Speed range | 0.01-500 mm/min | |||||||
Test schedule | ≥600mm (Can be customized according to customer's requirements) | |||||||
Test space structure adjustment | Ac servo motor, low noise synchronous belt transmission | |||||||
Protection function | Overload protection, limit protection | |||||||
Power (V) | 220 | 380 | ||||||
Working environment | Room temperature-45℃, humidity 20%-80% | |||||||
Fixture shape | According to customer's requirement, configuration suitable fixture. Special fixture can be customized according to customer | |||||||
Overall dimensions (mm) | 700*580*1720 | 700*580*1850 | 1100*770*2600 | 1400*1100*2870 | ||||
Weight (kg) | 450 | 550 | 2000 | 3000 |