water desalination equipment ro+EDI machine
water desalination equipment ro+EDI machine
water desalination equipment ro+EDI machine

1 / 1

water desalination equipment ro+EDI machine

Get Latest Price
Send Inquiry
Model No. : XSTRO+EDI
Brand Name : XST

Product description

water desalination equipment ro+EDI machine Specification 3.0TPH seawater desalination plant for drinking water 1.DOW CSM membran for your option
2.ISO certificate,patents
3.One year warranty
4.12 years experience, water treatment solution provided  Company instruction:  Xi’an Xinshengtai (XST) Water Treatment Technology Co., Ltd.   (Formerly Xi’an Shengtaihuagong Science & Technology Co., Ltd.) was founded in 2003.   It’s an environmental friendly hi-tech company that specializes in research, production, and sale of water treatment equipment.  Since established, XST has finished thousands of water treatment projects, involving chemical industry, power plant desalination   water, electrodeionization ultra pure water, medical industry, aviation cleaning, food and beverage industry, municipal heating,   softened circulating water, living water purification, brackish water desalination, sea water desalination, industrial waste water   treatment, reclaimed water reuse, rural area drinking water project, and etc. Xinshengtai Environmental Protection Industrial Park was built in 2011 in Xi’anXianyang New Area, which occupies 24,000 square meters. We now have 150 staff, with 50% of which have senior or advanced title.   And we established long term partnership with many universities and scientific research institutions in Xi’an. Our experienced and well trained staff can provide first class one stop services from on site investigation, project design, business   negotiation, installation and adjustment, to after sales service. RO main component list:                                                                             1.Standard back flushing pump(with electric machine)/inlet solenoid valve                                                   2.Back flushing dosing device/5μm precision filter/integrated membrane housing   3. DOW  membrane/ Hydraulics                               4.Automatic chemical self washing mechanism/baking finish or S.S frame                                        5.Supervisory meters,such as concentrated water pressure gauge,flow meter,conductivity apparatus     6.Automatic control   Design basic data (For reference only,exact specification is subject to raw water and product):                1.Inlet water SDI(15 MINS):<5                                                                                                                       2.Inlet water TURBIDITY:<1.0NTU                                                                                                                3.Inlet water Fe:<0.005ppm                                                                                                                           4.Inlet water chlorine:(mg/l)<0.1                                                                                                                     5.Inlet PH:2~11                                                                                                                                               6.Inlet water temperature:4~45℃                                                                                                 7.Desalination rate:95~99%                                                                                                                           8.Outlet water PH:5~7   9.Output water meet the WHO drinking standard Standard system:
Model Capacibility Operation Inlet Membrane Membrane (QTY) Recovery Power
(Tons/Hr) (MPa) Size(MM) Size(inch) (KW)
XSTRO-125L 0.125 1.0-1.4 DN20 40×21 1 30% 1.1
XSTRO-250L 0.25 1.0-1.4 DN20 40×40 1 50% 1.1
XSTRO-500L 0.5 1.0-1.4 DN20 40×40 2 50% 1.5
XSTRO-750L 0.75 1.0-1.4 DN25 40×40 3 60% 2.2
XSTRO-1000L 1 1.0-1.4 DN25 40×40 4 60% 2.2
XSTRO-1500L 1.5 1.0-1.4 DN25 40×40 6 60% 3
XSTRO-2000L 2 1.0-1.4 DN25 40×40 8 60% 3
XSTRO-250LDP 0.25 1.0-1.4 DN20 40×40 3 50% 2.6
XSTRO-500LDP 0.5 1.0-1.4 DN25 40×40 5 50% 3.7
XSTRO-1000LDP 1 1.0-1.4 DN25 40×40 10 60% 5.2
XSTRO-2000LDP 2 1.0-1.4 DN25 40×40 16 60% 7
XSTRO-2.5 2.5 1.0-1.4 DN32 40×40 10 65% 4
XSTRO-3 3 1.0-1.4 DN32 40×40 12 65% 4
XSTRO-6 6 1.0-1.4 DN40 80×40 6 65% 5.5
XSTRO-10 10 1.0-1.4 DN50 80×40 10 75% 11
XSTRO-15 15 1.0-1.4 DN50 80×40 15 75% 15
XSTRO-20 20 1.0-1.4 DN65 80×40 20 75% 18.5
  Technical Route: Raw tank-->raw water pump-->quartz sand filter-->activated carbon filter-->water softer--> sediment filter (cartridge filter 5um )-->high pressure pump-->RO desalination device-->permeate water tank   What types of water sources does it treat? Reverse Osmosis is an ideal water treatment solution in most types of water. Generally speaking, all major water sources from a treatment standpoint can be broken down into three major categories: tap water, also known as municipal sources, undergroundwater, which includes brackish water, and saltwater. The biggest distinction between these three types is the Total Dissolved Solids (TDS) content of each type. As a rule of thumb, the American Health Association requires that drinking water is under 1,000 PPM TDS.Reverse osmosis is often used in a tap water environment to reduce hardness, or the debris deposited in water from traveling in metal pipes. Total dissolved solids is often a target of water purification in tap water systems.Underground reservoirs of water are often brackish, meaning they contain large volumes of salt, but not enough to be considered salt water. Groundwater is most often purified for the agriculture industry, the mining industry. Groundwater is also a prized target of the bottling industry, because the unique mineral combinations often have an appealing taste.
Salt water reverse osmosis (sometimes referred to as desalination) is the turning of saltwater into drinking water. Ocean water has up to 45,000 PPM TDS. The biggest uses of desalination come in providing water in areas that lack a regular supply of fresh water.  Is pretreatment necessary? It is very important that feed water be preconditioned to protect the membranes from fouling causing premature failure.The membrane is constructed of a porous material that allows water to pass through, but rejects up to 99% of the dissolved solids at the surface. The dissolved salts are concentrated reject water (brine stream), where they are discharged to waste. Removing things prior is key to letting the RO system do what it was meant to do.As the RO System continues to operate, the dissolved and suspended solids in the feed water tend to accumulate along the membrane surface. If these solids are allowed to build up, they eventually restrict the passage of water through the membranes, resulting in a loss of throughput. (The throughput capacity of the membranes is commonly referred to as the flux rate, and is measured in gallons per square foot of membranes surface area per day.)
Early in the development of membranes systems, little was known about which impurities in the feed water were likely to cause fouling and a corresponding reduction in flux. Today, many of these troublesome impurity treatments have been identified, and preventive treatments have been devised that greatly reduce membrane fouling, thus prolonging the life of the RO System.
Is it necessary to get a water analysis? A detailed chemical analysis (LSI, SDI, or CFI) of the RO feed water is an absolute necessity for identifying potential foulants. This should include a measurement of the hardness (calcium and magnesium), barium, strontium, alkalinity, pH, and chlorine. The data from the chemical analysis can be used by the engineers designing the system to determine the optimum  membrane array that will both minimize the tendency of scale and deposit formation and maximize the recovery and flux rate.
What determines the precise pretreatments for a particular RO? In one word: analysis. Every source of water is different, and you never know what's in your water until you have it analyzed. The water analysis, LSI, SDI, or CFI values are used to determine the precise pretreatment requirements for a particular RO System. Since water supplies vary considerably from one location to another, each pretreatment requirement will be different.
Does the feed water need to be softened by the RO? Ion exchange is a popular method for softening and reducing the potential for mineral scale formation on the membrane surface. Ion exchange softening uses sodium to replace scaleforming ions such as calcium, magnesium, barium, strontium, iron, and aluminum to prevent damage to the membrane elements. The sodium forms very soluble salts, which are readily rejected by the Reverse Osmosis System and do not readily form mineral scales on the membrane surface. A sodiumcycle softener is regenerated with sodium chloride brine. The spent regenerant, along with the softener rinse water, must be discharged to waste. It is because of this that ion exchange is recommended for applications that have high metal contents in the treated water. What is dechlorination used for?  Generally speaking, chlorination is a doubleedged sword when it comes to reverse osmosis systems. As a method of disinfection, chlorination is not only efficient and practical, but it is costeffective as well. The only problem is that chlorine is too caustic for membrane elements, and can cause serious damage. Dechlorination is a kind of chemical injection that forms salts with chlorine, making it readily rejected by the membrane elements. In this circumstance, dechlorination is a must as far as water treatment is concerned. Without dechlorination, reverse osmosis membranes are not only ineffective, but the chlorine will simply destroy the protein membrane.  Is acid injection necessary?  Just as acidic solutions aren't good for membranes, caustic solutions are equally damaging to membrane elements. Acid injection may be incorporated into the RO pretreatment system to control pH and minimize the scale-forming tendency of the feed water. Acid injection is indicated if the scale forming tendency of the brine stream is above +0.3 as measured by the LSI. Either sulfuric or hydrochloric acid can be used for this purpose.   What does an antiscalant do? Antiscalants have been shown to be effective in extending the intervals between chemical cleanings of the RO membranes. These products are generally formulated to include inorganic phosphates, organophosphates, and dispersants. Some Antiscalant contain negatively charged polymers and dispersants that can react with cationic polymers that might be dosed up stream prior to the media filters. The Antiscalant must be compatible with these polymers; otherwise, the reaction product  will foul the membranes.  Do all systems require chemical cleaning?  Despite all efforts to protect the system from fouling and lose flux, eventually the membranes will require chemical cleaning. A welldesigned RO system will include provisions for a cleaning skid to facilitate the cleaning process. The skid should include a chemical tank, solution heater, recirculating pump, drains, hoses, and all other connection and fittings required for accomplishing a complete chemical cleaning of the RO modules.  Summary
Reverse osmosis is a reliable method for producing highpurity water. However, most water supplies require some form of RO pretreatment such as softening, media filtration, activated carbon, or chemical injection to protect the membranes from premature fouling or failure. The pretreatment requirements will vary from location to location, but the overall objective remains the same: to maintain the design flux rates, minimize the membranes cleaning frequency, and prolong the useful life of the RO equipment.  Reverse Osmosis system reference picture:       1. Raw water pump-- provide the pressure to quartz sand filter/active carbon filter 2. Multi-medium filter-- get rid of turbidity, suspended matter, organic matter, colloid, ect 3. Active Carbon filter--Remove the color, free chloride, organic matter, harmful matter, ect. 4. Softener--exchange "ions" of calcium and magnesium with the most common and easiest method. 5. Micron filter--prevent large particles, bacteria, viruses into RO membrane, accuracy is 5um. 6. High pressure pump-- Provide the high pressure to RO membrane ro. 7.RO system--main part of the plant. The RO membrane's desalting rate can reach 99%, removing over 99% ions. 8.Chemical cleaning system--clean the RO system whn the RO sysem function decline. 9.Electric Cntrol system--relay  ot PLC for your option  Our Factory,package&shiping&office:  Contact: skype: fuchunli566 QQ 790491046 wechat: fuchunli002 phone: +86 18220481290  
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628