Specifications Volumetric Piston Rotary Water Meter
ISO 4064 Class C
Horizontal type brass body
Remote device can be added up on request
Features: Rotary piston system.long service life Dry-dial or liquid sealed register,keeps clear reading for long time°c High measuring accuracy,the starting flow of the meter is 2 L/Pulse or less Can be installed in any position Brass body,m³ or gal,optional Remote transmisson can be added upon request Many kinds of sensors,such as Reed Switch,Hall and Weagand can be supplied upon request; Pulse output maybe 1L/Pulse ISO 4064 :1993 Class C ISO 4064:2005 R160/R200 Working condition: Water temperature 50°c Water pressure≤1MPa (PN:1.6MPa/16bar) ΔP≤0.1MPa(Class C/Class D) ΔP≤0.063MPa(R160/R200) Accuracy: From minimum flow-rate(qmin/q1)inclusive, to transitional flow-rate(qt/q2),exclusive:±5% From transitional flow-rate (qt/q2)inclusive,to overload flow-rate(qs/q4),exclusive::±2% Technical Data:
DN/Q | Q4=1.25Q3 Q3 | R=Q3/Q1 | Q2=1.6Q1 Q1 | R=Q3/Q1 | Q2=1.6Q1 Q1 |
l/h | l/h | l/h |
15 | 3125 2500 | 160 | 40 16.25 | 200 | 20 12.50 |
Nominal size DN9mm) | Classof measurement | Overload flow-rate qs | Permanent flow-rate qt | Transitional flow-rate qt | Minimum flow-rate qmin | Minimum reading Min | Maximum reading Max |
15 | C | 3 | 1.5 | 22.5 | 15 | 0.0001 | 9999 |
Overall dimensions and weight:
Type | Size(mm) | Length(mm)L | Width(mm)W | Height(mm)H | Connecting Thread D | Weight (kg) |
LXH-15E | 15 | 165 | 165 | 115 | G3/4"B | 1.7 |