Vertical Flow Laboratory Clean Room Cabinets Stainless Stee
Vertical Flow Laboratory Clean Room Cabinets Stainless Stee
Vertical Flow Laboratory Clean Room Cabinets Stainless Stee

1 / 1

Vertical Flow Laboratory Clean Room Cabinets Stainless Stee

Get Latest Price
Send Inquiry
Model No. : YJ-VS-1
Brand Name : Yijing

Product description

Vertical Flow Laboratory Clean Room Cabinets Stainless Steel , 990×750×1620mm

Quick Detail:

1.Name: YJ-VS-1 Single Person Use Clean Bench

2. Brand Name: YIJING

3. Material: Out cabinet Cold Steel, Inner side Stainless Steel SUS304

4. Feature: Touch-up Switching Regulator Air flowing

5. Outside dimension: 990×750×1620 (mm)

6. Certificates: CE,ISO

Description:

1.Usage:The product is applied with a vertical laminar flow air supply, widely used in a variety of electronics, precision instruments , pharmaceuticals , cell culture, tissue culture flowers , food, cosmetic , animal husbandry , veterinary , bio-engineering , universities and various class laboratories and other industries and research and leadership.

2. Features: Equipped with Energy-saving overhead VAV air systems, with high performance, long life and high efficiency air filters, the filtration efficiency ≥ 99.995%( sodium flame method ),the dust particle size ≥ 0.5μm, which guarantee the operating room meets U.S. Federal Standard 209E ( one hundred purification standards).

3. Smart design and user-friendly combination: Three sides of the spacious work area with high-quality 304 stainless perspective glass countertops, both effectively enhancing the comfort and spaciousness, but it is also anti-bacterial , anti-corrosion , easy to clean and functional whole work. Sealed units can be used for two -handed operation workbench holes , the hand can go into his role , while at the same raise up the entire panel , open convenient operation.

5. Safe and reliable safeguards: It is Strict accordance with international electrical safety standards designed, ensuring the product has multiple security measures , the use of soft -type UV germicidal lamp lighting control with individual control , and needs to be noted that only work before UV germicidal open sterilization, when the work does not allow people to open UV germicidal lamp , UV germicidal lamp to avoid causing burns to human skin.

Technical Parameters

Item

Data

Number of Aerobic Plate

≤0.5/m·h

Filtration Efficiency

≥0.3um (for the diameter of particle)
≥99.995% (for the dust with sodium flame method )

Average Air Flow Speed

≥0.5m/s ±20% (adjustable)

Noise

≤62dB (A)

Vibration

≤3um (in the directions of X, Y, Z)

Illumination

≥300lx

Power Supply

220V 50Hz

Illumination Lamp

20W×2

Ultraviolet Lamp

20W×2

Max. Power Consumption

400W (Rated Power)

Outside Dimension (W×D×H)

990×750×1620mm

Dimension of Operation Area

830×700×520mm

Dimension

Medium Efficiency Air Filter

437×390mm

High Efficiency Air Filter

790×600×120mm

Weight

110kg

Why to choose YIJING Brand Clean Bench?

1) 15+ years experience.
2) 1000 + successful cleanroom projects completed.

3) Turnkey In-House Cleanroom Engineering and Design Capabilities.

4) Manufacturing all major components In-House.
5) Not only a manufacturer, also a specialist of cleanroom solution.

6) Multiple wall finishes to meet any standard.

7) Many cleanroom alternatives.

8) Factory-trained staff for custom cleanroom.
9) Assist you with cleanroom materials and equipments, as well as technology support.

10) Complete integrated service.

Communication with customers

A: Could I know YIJING Brand Clean Bench is one hundred class level?

B: Yes, clean bench standards are in accordance with U.S. Federal Standard 209E cleanliness to produce, all are tested before ex-factory, the standard is based on 0.5 micron dust particle filtration efficiency : 99.995% ; YJ -VS -1 Clean bench can reach to 0.3 micron dust particle one hundred cleansing effect.

A: Should I choose Vertical or Horizontal Clean bench?
B: The effect of horizontal and vertical clean bench are the same, which both meet the U.S. Federal 209E Standard. Usually, general hospitals, biological research and pharmaceutical industries will choose vertical because vertical downward air. Horizontal direction is blowing against person, while some irritating and toxic gases if blown directly into personnel will staff causing bodily harm , in which case the general choice of a vertical well ; food testing, mushroom etc. usually choose horizontal.

A : What is the principle of clean bench?
B: The working principle is: the air sucked through the fan pre-filter, through the medium efficiency filters, and then by the plenum into the high efficiency filters , the filtered air to the state of the vertical or horizontal airflow sent, so that the operating area reached one hundred cleanliness, to ensure the production of environmental cleanliness requirements.

A: Why choose medical perpendicular better?

B: Because some pharmaceutical or medical generally irritating gas detection , testing, these flavors gas liquids may harm the human body , it is a closed vertical bench is ideal , effective protecting personnel from outside odor stimuli.

Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628