Type : Air Flow Sensor
Measuring range : 50,100,150,200,300slm
Output Signal : 1-5v
Working Voltage : 7-14v
Pressure range : 200kpa
Response time : 50ms
Working Temperature : -25~65℃
Repeatability : ±0.3, ±0.5%f.S
Product Name : Versatile High-Precision 200 300slm Air Sampling Flow Sensor Meter
place of origin : China
Certification : /
Place of Origin : Shaanxi, China
Brand : Gaimc
More
3yrs

Xian, Shaanxi, China

Visit The Store
  • Gold Supplier
  • Platform Certification

Product description

Micro air flow sensor adopts thermodynamic principle to detect the gas flow, and it has high accuracy and good repeatability. The built-in temperature sensor makes the product has the function of professional temperature compensation calibration. At the same time, the output is linear analog voltage which is convenient to use.We have more than 10 years of experience in the production and sales of flow meters, including ultrasonic flow meter and electromagnetic flow meter.

Description 

GFS131U Versatile high-precision 200 300SLM Air sampling flow sensor meter

Detail show 

Main Applications: Portable detector / Industrial process control / Air and environment protection

GFS131U Versatile high-precision 200 300SLM Air sampling flow sensor meter 

Features

Latest MEMS Sensor chip technology

High accuracy, quick response, good repeatability

Detection micro flow accurately

It is calibrated completely and temperature compensated 

Parameters

 Technical Parameters

Model GFS131U
 Measuring Range   50,100,150,200,300 SLM   
   Min  Typical Max Unit
 Full Scale Output  4.90  5.00  5.10  V
 Zero Output  0.96  1.00  1.04  V
 Output Impedance  -  200  -  Ω
 Working Voltage  7.0  10.0  14.0  V
Working Current  15  25  30  mA
Accuracy  -  ±1.5  ±2.5  %F.S
Repeatability  -  ±0.3  ±0.5  %F.S
Annual Drift   -  ±0.1  ±0.5  %F.S
Pressure range   -  -  200  kPa
Response Time 45  50  55  ms
Working Temp.   -25  -  65  ℃
Storage Temp.  -40  -  90  ℃

 GFS131U Versatile high-precision 200 300SLM Air sampling flow sensor meter


 Pins Definition 

Pin Function
1(black or gray) GND
2(red) VCC
3(yellow) OUT
NOTE:
1.The measuring range within 50-300SLM is available and regular measuring ranges such as 50,
100,150,200,300SLM.Customized fee will be charged for other ranges.
2.SLM means standard liter per minute. Standard-state: gas temperature is 20℃ and pressure is 101.325 kPa.
3.Customization of response time between 10ms and 1000ms. This response time refers to the electronic response time by the flow sensor for any mass flow change from 10% to 90%. which may be affected by the aerodynamic interface.
4.The temperature compensation is for the temperature range of 0-50℃ and the compensation performance can’t be ensured beyond the temperature range.

Calculation for Airflow

 Actual flow=full scale * (sensor actual output voltage-zero output voltage) / (full scale output voltage-zero output voltage)
For example: the sensor full scale is 200 SLM, the sensor zero output voltage is 0.5V and full scale
output voltage is 4.5V, and the actual output is 3.5V.
Then the actual flow=200 SLM * (3.5V – 0.5V)/(4.5V- 0.5V) = 150SLM

Cautions

1. The air inlet and air outlet of the sensor need to be equipped with long straight pipe to ensure the product’s performance. It is recommended to leave a straight pipe for the inlet with 10 times longer than the pipe diameter while the outlet will be 5 times longer.

2. If measured gas medium contains dirt, the sensor’s lifespan will be shortened. We suggest users equip the sensor flow inlet with 5 micrometer precise filter.

3. The sensitivity of the product will reduce or be damaged if it contacts to water.

4. The wrong connecting of power supply will damage the internal circuit.

Voice of customer 



Company information 

GFS131U Versatile high-precision 200 300SLM Air sampling flow sensor meter


Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628