UPS Uninterruptible Power Supply (HT)
UPS Uninterruptible Power Supply (HT)
UPS Uninterruptible Power Supply (HT)

1 / 1

UPS Uninterruptible Power Supply (HT)

Get Latest Price
Send Inquiry
Model No. : HT
Brand Name :

Product description

Features:

1. Sine-wave output:
True sine-wave output with less than 3% THD.

2. Double Conversion Design:
Zero transfer/ complete isolation of input AC.

3. UPS Monitoring Software:
Powerful true RS232 communication via the enclosed software
To manage and safely shutdown operating systems.

4. Network RJ45/11 protection:
Complete powerful network and phone line surge protection.

5. AC Surge Suppressor:
Powerful multi-stage surge components that exceed IEEE requirements.

6. SNMP Slot Option:

7. Sleep Mode:
Worry free battery management. The unit turns itself off after ten seconds to conserve battery
Power when no power needs are detected.

8. Battery level indicators:
LED''s indicate battery levels.

9. Load Sensing:
The incorporated LED load indicators allow IT professionals to manage backup time and balance
Power loads.

10. Low Battery indicators:
The low battery level indicator will warn of eminent UPS shutdown two full minutes before unit shuts
Down.

11. Replace Battery indicators:
A preventative measure that indicates when batteries must be replaced to prevent
Server crashes.

Model
HT1KS
HT2KS
HT3KS

Rated Power
VA/W
1kVA / 0.7kW
2kVA / 1.4kW
3kVA / 2.1kW

Input
Nominal Voltage
220VAC

Voltage Range
115 ~ 300VAC

Frequency Range
46 ~ 54Hz(default), user adjustable within 40~60Hz

Power Factor
0.97

Connection
IEC320 -10A inlet
IEC320 -16A inlet

Output
Voltage
220VAC+- 2%

Frequency
46~54Hz or 50Hz+- 0.2Hz (Line mode)
50Hz+- 0.2Hz ( Battery mode)

Waveform
Sine Wave

Distortion
3%
4%

Overload Capability
108% ~ 150% for 30 sec., 150% for 300 ms

Current Crest Ratio
3: 1

Connections
IEC320 -10A *4
IEC320 -10A *6
IEC320 -10A *3 and
Terminal Block

Battery

Type
Sealed, Maintenance free, Lead-Acid

Nominal DC Voltage
36VDC
96VDC

Back-up Time
Depends on the capacity of the external battery bank

Connection
External Battery Socket

Bypass

Automatic Transfer
On overload and UPS failure

Before UPS Power-on
Default "NO", user adjustable to "YES"

Voltage Range
80 ~ 264VAC (Default), user adjustable within 80 ~ 286VAC

Transfer Time
0 ms; Less than 4 ms from inverter to bypass and vice versa

LED Indicators
Status
Load level / Battery level, Battery, Utility Power, Inverter, Bypass, Overload, Fault

Audible Alarm
Bypass, On battery mode, Battery low, Overload, Fault

Acoustic Noise
At 1 meter distance
45 dBA
50 dBA

Communications
dB-9 Port
RS-232 Serial Interface

Intelligent Slot
Options: WebPower, AS400 Card or WinPower CMC

Network Surge Protection
RJ45 I/O port available for 10 base-T network or Fax/Modem

Environmental
Operating Temperature
0 ~ 40C

Operating Humidity
20 ~ 90% non-condensing

Weight
Net (Kg)
7
13.5
14

Dimensions
W x D x H (mm)
145 x 400 x 220
192 x 460 x 348
Send Inquiry