1 / 6
Model No. : | 5208KPI |
---|---|
Brand Name : | DouWin |
Product description
Power supply | 4.5V DC |
Dynamic consumption | Static consumption |
Working temperatures | -20°C to 70°C |
Humility | 98% maximum |
Static power consumption | About 1 μA |
Dynamicpower consumption | Less than 150mApower |
Battery life Battery life | Normal about 1 million times, open after low-pressure hints about 150 times open. |
Payment Terms: | T/T,Paypal, Western Union |
Delivery time | 7 days after sample approval |
Application field | Widely used in the locker or cabinet of these place: swimming baths, saunas, golf course, gym locker, organs, enterprises,schools,hotels,supermarkets filing cabinet or store content ark, etc. |
1. The Private type | 2. The Public type |
1)When users forget password, inputmaster code to turn on, and then usercode will recover to default code;
2)When forget master code,keep pressing “Setup” button(On main PCB) about 3 seconds,then master code will recover to be default master code | 1) When users forget password, input “*#1#+the master code+#” to turn on,and then user code will recover to default code
2)When cleaning the cabinet ,use the master code to open the cabinet ,and the user code will not recover to default code.
3)When forget master code,keep pressing “Setup” button(On main PCB) about 3 seconds,then master code will recover to be default master code |
Public mode(Type) and Private mode(Type) can use master code to convert.
| |
Private mode convert to Public mode:
| * # 4 # Master code # |
Public mode convert to Private mode:
| * # 5 # Master code # |
Power supply:4 pcs AAA alkaline batteries
Battery life Battery life: Normal about 1 million times, open after low-pressure hints about 150 times open. | |
1. Private type(Independent type) mode: This lock can save one fixed code as user code. For example, if you set “12345” as User code successfully, the lock will be only opened by “12345” forever untill you set new other User code.
2. Public type(Open type) mode: This lock won’t save one fixed code as user code. It will cancel user code each time after you open door.User can change different code before closing door. For example, if you set “12345” as User code to close the door, the lock will be only opened by “12345”. However, if you open the door by “12345” , you can use any other code as User code to close the door. | |
Mechanical emergency open mode: Move out the Front panel, use Level screw driver to poke the U-shaped groove in lock body(Can’t use excessive force lest damage components), Them use Cross screw driver(3*100) to move that block to the end and undraw cabinet door. | |
external power supply
When battery have not enough power to drive motor,users can connect external power supply to (Battery box) supply power to turn on lock | |
shake handle function
|
1.Private type(Open type) mode: | 2.Public type(Independent type) mode: |
This lock can save one fixed code as user code.For example, if you set “12345” as User code successfully, the lock will be only opened by “12345” forever untill you set new other User code. |
This lock won’t save one fixed code as user code. It will cancel user code each time after you open door. User can change different code before closing door. For example, if you set “12345” as User code to close the door, the lock will be only opened by, “12345”. However, if you open the door by “12345” you can use any other code as User code to close the door.
|
Noraml fault |
Analysis of causes
|
Solution
|
Can’t open when the green light on | Lack of internal power supply | Use the external power supply to open, change the battery immediately after open |
The yellow light flicker always and have buzzing |
Enter the wrong code
| Enter the right code |
Press the key and have no reaction |
1. Lack of internal power supply 2.the winding displacement is unready
| 1. Use the external power supply to open, change the battery immediately after open 2.reset the winding displacement or change it |
Press the key and have no reaction(yellow light flicker) |
Enter the wrong code three times continuously
| Wait 5 minutes then use |