1 / 1
Model No. : | PT200-011G/015P-3B |
---|---|
Brand Name : | POWTECH |
Product description
Stable 11KW 380V 3 Phase Frequency Inverter Ac Drive For Motor
Quick Detail:
Name |
Variable Frequency Inverter |
Brand Name |
POWTECH |
Model |
PT200-011G/015P-3B |
IP class |
IP 20 |
Power,Voltage and current |
11KW,380V ac ± 15%,25A |
Certificate |
CE, RoHS, FCC |
Input&output |
Three phase input & three phase output |
Applicable motor |
3 phase ac Asynchronous motor |
Frame Size |
345/230/203mm
|
One PC Gross Weight |
10KGS |
Package Dimension |
405/263/280mm
|
Package Type |
POWTECH CARTON |
Description:
AC frequency vector inverters type |
Input voltage |
output rating (kW) |
Rated input current(A) |
Rated output current(A) |
Adaptive motor |
---|---|---|---|---|---|
PT200-0R4G-1B |
Single phase 220V ±15% |
0.4 |
5.4 |
2.3 |
0.4 |
PT200-0R7G-1B |
0.75 |
8.2 |
4.5 |
0.75 |
|
PT200-1R5G-1B |
1.5 |
14.2 |
7.0 |
1.5 |
|
PT200-2R2G-1B |
2.2 |
23.0 |
10 |
2.2 |
|
PT200-0R7G-2B |
Three phase 220V ±15% |
0.75 |
5.0 |
4.5 |
0.75 |
PT200-1R5G-2B |
1.5 |
7.7 |
7 |
1.5 |
|
PT200-2R2G-2B |
2.2 |
11.0 |
10 |
2.2 |
|
PT200-004G-2B |
3.7 |
17.0 |
16 |
3.7 |
|
PT200-5R5G-2B |
5.5 |
21.0 |
20 |
5.5 |
|
PT200-7R5G-2B |
7.5- |
31.0 |
30 |
7.5 |
|
PT200-011G-2B |
11.0 |
43.0 |
42 |
11.0 |
|
PT200-015G-2B |
15.0 |
56.0 |
55 |
15.0 |
|
PT200-018G-2B |
18.5 |
71.0 |
70 |
18.5 |
|
PT200-022G-2 |
22.0 |
81.0 |
80 |
22.0 |
|
PT200-030G-2 |
30.0 |
112.0 |
110 |
30.0 |
|
PT200-037G-2 |
37.0 |
132.0 |
130 |
37.0 |
|
PT200-045G-2 |
45.0 |
163.0 |
160 |
45.0 |
|
PT200-055G-2 |
55.0 |
200.0 |
200.0 |
55.0 |
|
PT200-0R7G-3B |
Three phase 380V ±15% Notice: motor type above (including)350G G/P Can’t integrate
|
0.75 |
3.4 |
2.5 |
0.75 |
PT200-1R5G-3B |
1.5 |
5.0 |
3.7 |
1.5 |
|
PT200-2R2G-3B |
2.2 |
5.8 |
5 |
2.2 |
|
PT200-004G-3B/ PT200-5R5P-3B |
4.0/5.5 |
10/15 |
9/13 |
4.0/5.5 |
|
PT200-5R5G-3B/ PT200-7R5P-3B |
5.5/7.5 |
15/20 |
13/17 |
5.5/7.5 |
|
PT200-7R5G-3B/ PT200-011P-3B |
7.5/11.0 |
20/26 |
17/25 |
7.5/11.0 |
|
PT200-011G-3B/ PT200-015P-3B |
11.0/15.0 |
26/35 |
25/32 |
11.0/15.0 |
|
PT200-015G-3B/ PT200-018P-3B |
Three phase 380V ±15% |
15.0/18.5 |
35/38 |
32/37 |
15.0/18.5 |
PT200-018G-3B/ PT200-022P-3B |
18.5/22.0 |
38/46 |
37/45 |
18.5/22.0 |
|
PT200-022G-3B/ PT200-030P-3B |
22.0/30.0 |
46/62 |
45/60 |
22.0/30.0 |
|
PT200-030G-3B/ PT200-037P-3B |
30.0/37.0 |
62/76 |
60/75 |
30.0/37.0 |
|
PT200-037G-3B/ PT200-045P-3B |
37.0/45.0 |
76/90 |
75/90 |
37.0/45.0 |
|
PT200-045G/ PT200-055P-3 |
45.0/55.0 |
90/105 |
90/110 |
45.0/55.0 |
|
PT200-055G-3/ PT200-075P-3 |
55.0/75.0 |
105/140 |
110/150 |
55.0/75.0 |
|
PT200-075G-3/ PT200-093P-3 |
75.0/93.0 |
140/160 |
150/176 |
75.0/93.0 |
|
PT200-093G-3/ PT200-110P-3 |
93.0/110.0 |
160/210 |
176/210 |
93.0/110.0 |
|
PT200-110G-3/ PT200-132P-3 |
110.0/132.0 |
210/240 |
210/250 |
110.0/132.0 |
|
PT200-132G-3/ PT200-160P-3 |
132.0/160.0 |
240/290 |
250/300 |
132.0/160.0 |
|
PT200-160G-3/ PT200-185P-3 |
160.0/185.0 |
290/330 |
300/340 |
160.0/185.0 |
|
PT200-185G-3/ PT200-200P-3 |
185.0/200.0 |
330/370 |
340/380 |
185.0/200.0 |
|
PT200-200G-3/ PT200-220P-3 |
200.0/220.0 |
370/410 |
380/415 |
200.0/220.0 |
|
PT200-220G-3/ PT200-250P-3 |
220.0/250.0 |
410/460 |
415/470 |
220.0/250.0 |
|
PT200-250G-3/ PT200-280P-3 |
250.0/280.0 |
460/500 |
470/520 |
250.0/280.0 |
|
PT200-280G-3/ PT200-315P-3 |
280.0/315.0 |
500/580 |
520/600 |
280.0/315.0 |
|
PT200-315G-3/ PT200-350P-3 |
315.0/350.0 |
580/620 |
600/640 |
315.0/350.0 |
|
PT200-350G-3 |
350.0 |
620 |
640 |
350.0 |
|
PT200-400G-3 |
400.0 |
670 |
690 |
400.0 |
|
PT200-500G-3 |
500.0 |
835 |
860 |
500.0 |
|
PT200-560G-3 |
560.0 |
920 |
950 |
560.0 |
|
PT200-630G-3 |
630.0 |
1050 |
1100 |
630.0 |
Application fileds:
General type For 3 phase ac Asynchronous motor.
metal, petroleum, chemical, textile, electric power, building materials, coal, medicine, food, paper, plastics, printing and dyeing, lifting, cable, washing, water supply, heating and ventilation, sewage treatment and other industries, machinery and equipment for: Drawing machines, blenders, cutting machine, winding machinery, compressors, air pumps, grinders, conveyors, hoist, centrifuges and various speed control machinery.
Service promise
Quality assurance of the product in accordance with the following regulations:
1, Indeed the manufacturer responsibility of the quality assurance specific content:
1-1, calculated from the date of shipment
※refunding, replacement, repair kits within one month after the shipment
※replacement, repair within three months after shipment
※ repair within 12 months after shipment
1-2, When exported overseas (excluding domestic), located seller is responsible for repair kits within six months after shipment.
2, Regardless of when and where, the company brand products are enjoying services for life long
3, Across the country, the company sales, production, agent can provide after-sales service of the products, conditions of service as follow:
3-1, In the seat of the units providing "three-tier" checking services (including troubleshooting).
3-2, Need our after-sales service responsibility standards related to the contents of the contracts signed by the company with distribution agents.
3-3 can request the Powtech distribution agent for after-sales service (whether or warranty) with compensation.
4, there are quality problem or product incidents, we undertake only up to 1-1 or 1-2 in terms of responsibility, if users need more guarantee for liability ,please insure property insurance from the insurance company in advance.
5, nty for one year from the shipping date.
6, In the case of the following causes of failure, it is also a paid repair even during the warranty period
6-1, Caused by incorrect operation (based on manual) or repair and renovation without permission
6-2, he problems caused by the drive beyond the standard specification requirements.
6-3 Caused by improper or handling damage after purchasing
6-4, Aging or failure of the device caused by the adverse environment
6-5, Caused by accompanied reasons due to earthquake, fire, flood, lightning, abnormal voltage or other natural disasters.
6-6, Damage during transport (Note: The mode of transport is specified by the customer, and the Company assists to handle the goods transfer formalities).
6-7, labels such as the brand, trademark, serial number and nameplate, are defaced or illegible.
6-8, Failure to purchase the agreed payment in full.
6-9 can not be objectively actual description to the service units for installation, wiring, operation, maintenance, or other use.
7, Before get the service: refunding, replacement, repair services, you should return products to the company and then confirm the attribution of responsibility.
Unlock the mysteries of variable frequency drive(VFD)
Glad to share with you for variable frequency drive(VFD) :
which is also termed adjustable frequency drive, variable speed drive, AC drive, micro drive or inverter drive) is a type of adjustable speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.
Benefit of VFD:
Energy saving ,Tighten process control, make industry control more easier and Reduce equipment maintenance by installing variable frequency drives (VFDs)
Appliances of VFD:
VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, about a third of the world's electrical energy is consumed by electric motors in fixed-speed centrifugal pump, fan and compressor applications and VFDs' global market penetration for all applications is still relatively small. This highlights especially significant energy efficiency improvement opportunities for retrofitted and new VFD installations.
Specifications
Power PT200-011G/015P-3B |
|
POWER ,Voltage ,frequency level and current |
11KW, Three-phase 380V±15%,50/60HZ ,25A |
Allowable fluctuations |
voltage:+-15% frequency:+-15% |
Control performance |
|
Control system |
DSP-based high-performance vector control inverter |
Output frequency |
G/P type: 0.00-400Hz, the maximum frequency could be set on the range of 10.00Hz-400Hz |
Control method |
V/F control, open-loop magnetic flux vector control 1,open-loop magnetic flux vector control 2,PG vector control |
Automatic torque boosting function |
low frequency(1Hz)powerful output torque can be achieved under the V/F controlling |
Accelerate/decelerate control |
Segment S curve acceleration and deceleration set mode, maximum running time is 9600 hours |
Program-running control |
16 segments speed running, maximum running time is “888.88 hours” |
Frequency setting accuracy |
Digit:0.01Hz(below 300Hz),0.1Hz(above 300Hz);analogue:1% of maximum frequency |
Frequency accuracy |
Speed control tolerance 0.01%( (25℃±10℃)) |
V/F curve mode |
Linear, square root, user-definition set V/F Curve |
Over load capability |
G type: rated current 150%-1minute,200% of rated current-0.1 second P type: rated current 120%-1minute,150% of rated current-0.1 second |
Slip compensation |
50%-100%,automatically compensate for deterioration |
Maximum frequency |
400Hz |
Carrier frequency |
0.5K-15KHZ. According to the load characteristics, automatically adjust the carrier frequency |
Input frequency resolution |
Digit setting:0.01Hz Analogue setting: Maximum frequency*0.1% |
Start torque |
G type:0.25Hz/180% P type:0.25Hz/120% |
Adjusting-speed range |
1:200 |
Steady speed accuracy(speed control accuracy) |
open-loop magnetic flux vector control:+-0.5%(rated synchronous speed) |
Speed control stability |
open-loop magnetic flux vector control:+-0.3%(rated synchronous speed) |
Torque response |
≤40ms(open-loop magnetic flux vector control) |
Torque boost |
Automatic torque boosting; manual torque boosting0.1%-30% |
Acceleration and deceleration linear |
Linear accelerator Mode: four acceleration and deceleration time; Acceleration and deceleration time range 0.0s-3600.0s |
Dc brake |
DC brake frequency:0.0Hz-maximum frequency, braking time: 0.0~36.0 second,Braking operation time:0.0%~100 |
Jog control |
Jogging frequency range: 0.00Hz - maximum frequency, jog acceleration and deceleration time: 0.0s-3600.0s |
Multi-segment speed running |
achieve up to 16 segment speed run via the control terminal |
Built-in PID |
Facilitate the realization of the process control closed-loop control system |
Automatic Voltage Regulation |
When the grid voltage changes, automatically maintain a constant output voltage |
Torque limit and control |
Dig-earth machine features, the running torque is automatically limited to prevent frequent over-current trip to pure control can be achieved under close-loop vector mode |
Personalization features |
|
Power-on peripherals, security self-inspected |
Safety of the peripherals equipments can be checked when power on, such as grounding, short circuit ,etc |
Common DC bus function |
The function of multiple inverters share the DC bus |
MF key |
Programmable keys: Reversible run/ Jog operation function selection |
Textile pendulum frequency control |
Variety of triangular wave frequency control function |
Wave-filter and current-limiting function |
Built-in wave-filter and current-limiting calculation method to reduce the frequency reported flow probability, improve the whole anti-jamming capability |
Timing control |
Timing control function: to set the time range Oh-65535h |
Keyboard extended cable standardization |
Customer can extend the keypad cable with standard cable. |
Input signal |
|
Running method |
Keyboard/terminal/communication |
Frequency setting |
7 kinds of frequency setting, including adjustable DC 0-10v range, adjustable DC 0-20mA range, panel potentiometer, etc |
Starting signal |
Forward, Reverse |
Multi-segments speed |
Up to 16 segments speed can be set(using the multi-function terminal or program run) |
Multi-segments acceleration |
up to 4 segments acceleration can be set(using the multi-function terminal) |
Emergency stop |
Interrupt control output |
Pendulum-frequency running |
Process control running |
Jogging |
Running slowly |
Fault reset |
When the protection function is active, you can automatically or manually reset the fault condition |
PID feedback signal |
DC 0~10V,DC 1~5V,DC 0~20mA,DC 4~20mA |
Output signal |
|
Running status |
Motor status display, stop, acceleration and deceleration, constant speed, the program running state |
Fault output |
contacting point output AC 250V 5A, DC 30V 5A |
Analogue output |
Two ways analog output, you can select the eight kinds of frequency, current, voltage, temperature and other 8 signals, the output signal range can be set arbitrarily on the range of 0-10V/0-20mA |
Output signal |
Up to 3 output signals and there 9 signal for selection. |
Running function |
|
Running function |
Frequency limit, avoiding frequency ,slip compensation, reverse protection, self-tuning, PID control. |
DC current brake |
Built- in PID regulate braking current to ensure adequate braking torque without over current |
Operation command channels |
Three channels: the operation panel set, control terminals set, serial communication port set. Variety of means switching |
Frequency source |
There are 6 kinds of frequency source: digital set, analog voltage set, analog current set, multi segment speed set, a serial port set, PID set, Variety of means switching |
Input terminal |
6 digital input terminals, compatible with active PNP or NPN input methods two analog input terminal, which AI1 can only be used as input voltage, AI2 can be as voltage or current input(if it needs to expand input, output terminals function) |
Output terminal |
A digital output terminals(dual polarity output) a relay output terminals an analog output terminals, 0/4 mA-20mA or 0/2V-10V is optional, the set frequency ,frequency output, speed and other output of the physical quantities can be achieved. |
Protection function |
|
Inverter protection |
Overvoltage protection, undervoltage protection, overcurrent protection, overload protection, over-temperature protection, over the loss of speed protection, over-voltage stall protection, phase protection(optional), external fault, communication error, PID feedback signal abnormalities, PG failure. |
IGBT temperature display |
Display present IGBT temperature |
Inverter fan control |
The fan starting temperature can be set(optional) |
Instant power-down re-start |
Less than 15 mills seconds: continuous operation. More than 15 milliseconds: Automatic detection of motor speed, instantaneous power-down re-start |
You may also be interested in: Send your inquiry to this supplier |