1 / 6
Model No. : | TUF-2000SW |
---|---|
Brand Name : | TSONIC |
Product description
Main Unit | Transducer | |
Protection Level | IP65 | IP68 |
Humidity | ≤85%RH | |
Temperature | -20~60℃ | -30~160℃ |
Accuracy | ≤1% |
Velocity range | 0~±10m/s, Bi-directional measurement |
Pipe size | DN32~DN6000mm |
Temperature | -30~160℃ |
Type of liquid | Single liquid can transmit ultrasound, such as water, sea water, sewage, oil, alcohol, etc. |
Pipe material | Steel, stainless steel, cast iron, copper, PVC, aluminmum, glass steel, etc. Liner is allowed. |
Signal output | 1 way 4-20mA output 1 way OCT pulse output 1 way Relay output |
Signal input | 3 way 4-20mA input, achieve to heat measurement by connecting PT100 platinum resistor. |
Interface | RS485, support MODBUS |
Data storage | SD card regularly store the pre-set results(optional) |
Power supply | DC8~36V or AC85~264V |
Nominal Diameter
(DN) |
Pressure Level
P |
Length
L | Flange Size | Standard
| ||||||
Outer Diameter D | Diameter of centre hole in bolts D1 | Diameter of bolt hole×Quantity φ × n | Diameter of sealing surface D2 | Flange thickness | Bolting Specification | |||||
C | f | |||||||||
40 | 1.6 | 300 | 150 | 110 | 18×4 | 84 | 18 | 2 | M16×60 | GB/T 9919-2000
|
50 | 1.6 | 300 | 165 | 125 | 18×4 | 99 | 20 | 2 | M16×70 | |
65 | 1.6 | 330 | 185 | 145 | 18×4 | 118 | 22 | 2 | M16×70 | |
80 | 1.6 | 225 | 200 | 160 | 18×8 | 132 | 20 | 2 | M16×70 | |
100 | 1.6 | 250 | 220 | 180 | 18×8 | 156 | 22 | 2 | M16×80 | |
125 | 1.6 | 275 | 250 | 210 | 18×8 | 184 | 22 | 2 | M16×80 | |
150 | 1.6 | 300 | 285 | 240 | 22×8 | 211 | 24 | 2 | M20×80 | |
200 | 1.6 | 350 | 340 | 295 | 22×12 | 266 | 26 | 2 | M20×90 | |
250 | 1.6 | 450 | 405 | 355 | 26×12 | 319 | 28 | 2 | M22×90 | |
300 | 1.6 | 500 | 460 | 410 | 26×12 | 370 | 32 | 2 | M22×90 | |
350 | 1.0 | 550 | 500 | 460 | 23×16 | 428 | 28 | 2 | M20×80 | JB/T81-94 |
400 | 1.0 | 600 | 565 | 515 | 25×16 | 482 | 30 | 2 | M22×90 | |
450 | 1.0 | 700 | 615 | 565 | 25×20 | 532 | 30 | 2 | M22×90 | |
500 | 1.0 | 800 | 670 | 620 | 25×20 | 585 | 32 | 2 | M22×90 | |
600 | 1.0 | 1000 | 780 | 725 | 30×20 | 685 | 36 | 2 | M27×110 | |
700 | 0.6 | 1100 | 860 | 810 | 25×24 | 775 | 32 | 2 | M22×90 | |
800 | 0.6 | 1200 | 975 | 920 | 30×24 | 880 | 32 | 2 | M27×100 | |
900 | 0.6 | 1300 | 1075 | 1020 | 30×24 | 980 | 34 | 2 | M27×100 | |
1000 | 0.6 | 1400 | 1175 | 1120 | 30×28 | 1080 | 36 | 2 | M27×110 |
Nominal Diameter (DN) | Pressure Level P | Length L | Connecting Thread | Thread Effective length | Standard |
DN50 | 1.6 | 320 | G3/4B | 18 | GB/T7307-2001 |
DN20 | 1.6 | 360 | G1B | 15 | |
DN25 | 1.6 | 390 | G1 1/4B | 16 | |
DN32 | 1.6 | 450 | G1 1/2B | 22.5 |
Nominal Diameter
(DN) | Pressure Level
P | Length
L | Flange Size | Standard | |||||
Outer Diameter D | Diameter of centre hole in bolts D1 | Diameter of bolt hole×Quantity φ × n | Diameter of sealing surface D2 | Flange thickness include sealing surface C | Bolting Specification | ||||
DN50 | 1.6 | 320 | 95 | 65 | 14×4 | 46 | 14 | M12×50 | GB/T9119-2000 |
DN20 | 1.6 | 360 | 105 | 75 | 14×4 | 56 | 16 | M12×50 | |
DN25 | 1.6 | 390 | 115 | 85 | 14×4 | 65 | 16 | M12×60 | |
DN32 | 1.6 | 450 | 140 | 100 | 18×4 | 76 | 18 | M16×60 |
Types | Model | Measuring size | Insertion depth | Temperature | Installation requirements |
Three-wire high temperature transducer PT100 | PCT-1 | DN50 ~ DN150 | 210mm | -30~160℃ | No need to stop water |
DN200~DN250 | 250mm | -30~160℃ | |||
>DN300 | 340mm | -30~160℃ | |||
Two-wire high temperature transducer PT100 | PCT-2 | DN50 ~ DN150 | 210mm | -30~160℃ | No need to stop water. Used for battery powered ultrasonic flowmeter |
DN200~DN250 | 250mm | -30~160℃ | |||
>DN300 | 340mm | -30~160℃ |
Company Name | Dalian Taosonics Instrument Co., Ltd. |
Contact Person | Simon |
Tel | 86-411-84179922 / 86-411-84179933 |
Mobile | 86-18004261213 / 86-13842638462 |
Skype | simon_6807 |
Website | www.t3-1.com |
Send your inquiry to this supplier