Technical characteristics:
- Fiber count: 2 to 228
- Low loss/dispersion
- Proper design and precise excess length control offer nice mechanical and environmental properties to cable
- Corrugated steel tape armor brings better humidity-proof performance and side pressure-resistant
- Compact construction, lightweight and self-supporting installation
Performance:
- Applicable to long distance, inter-exchange communication, CATV and computer network transmission system
- Minimum bend radius:
- Operating temperature: -40 to +70°C
Fiber characteristic:- All characteristics of cable fiber (fiber of finished cable) shall be, at least, in accordance with ITU-T recommendation 657A/G.652D/G.652C
Characteristic of optical cable:- Cable bending radius:
- 10 x cable diameter (during operation)
- 20 x cable diameter (during installation)
Temperature range:
- Operating temperature range: -40 to +60°C
- Storage/transport temperature range: -50 to +70°C
- Installation temperature range: -20 to +50°C
Main mechanical and environmental characteristics test:
- Tensile strength: as per IEC 794-1-E1
- Crush test: as per IEC 60794-1-E3
- Impact test: as per IEC 60794-1-E4
- Repeated bending: as per IEC 60794-1-E6
- Torsion: as per IEC 60794-1-E7
- Water penetration: as per IEC 60794-1-F5B
- Temperature cycling: as per IEC 60794-1-F1
- Compound flow: as per IEC 60794-1-E14
- Sheath high voltage test: no sheath breakdown at 9t KV
Fiber count: 2 to 228
Low loss/dispersion
Proper design and precise excess length control offer nice mechanical and environmental properties to cable
Corrugated steel tape armor brings better humidity-proof performance and side pressure-resistant
Compact construction, lightweight and self-supporting installation
Applicable to long distance, inter-exchange communication, CATV and computer network transmission system
Minimum bend radius:
Operating temperature: -40 to +70°C
Static: 10D
Dynamic: 20D
All characteristics of cable fiber (fiber of finished cable) shall be, at least, in accordance with ITU-T recommendation 657A/G.652D/G.652C
Cable bending radius:
- 10 x cable diameter (during operation)
- 20 x cable diameter (during installation)
10 x cable diameter (during operation)
20 x cable diameter (during installation)
Operating temperature range: -40 to +60°C
Storage/transport temperature range: -50 to +70°C
Installation temperature range: -20 to +50°C
Tensile strength: as per IEC 794-1-E1
Crush test: as per IEC 60794-1-E3
Impact test: as per IEC 60794-1-E4
Repeated bending: as per IEC 60794-1-E6
Torsion: as per IEC 60794-1-E7
Water penetration: as per IEC 60794-1-F5B
Temperature cycling: as per IEC 60794-1-F1
Compound flow: as per IEC 60794-1-E14
Sheath high voltage test: no sheath breakdown at 9t KV