SEGC1120 GAS CHROMATOGRAPHY,GC CHROMATOGRAPHY
SEGC1120 GAS CHROMATOGRAPHY,GC CHROMATOGRAPHY
SEGC1120 GAS CHROMATOGRAPHY,GC CHROMATOGRAPHY

1 / 1

SEGC1120 GAS CHROMATOGRAPHY,GC CHROMATOGRAPHY

Get Latest Price
Send Inquiry
Model No. : SEGC1120
Brand Name : SELON

Product description

Specifications * High Sensitivity Detector

* Constant Gas Pressure

* 3 detectors may be installed and operated simultaneously.

                   TEL: +86 21 65416501       FAX: +86 21 35100022      SKYPE: selon-group     SEGC1120 GAS CHROMATOGRAPHY,GC   Temperature Control Temperature Range:7°C ~ 400°C above room temperature, (increment1°C) Tempperature Control Object:Column Box, front and back detecor, front and back sampler, assist,total six channels. Program ramps : 7 ramps in total Program setting:0.1°C~40°C/min(increment 0.1°C) Total time of total program : Up to 655 minutes, (increment 0.1°C)   Hydrogen flame ionization detector (FID) Minimum detectable quantity: M≤8×10-12g/s (C16) Best test result: M≤3×10-12g/s (C16) Noise: ≤5×10-14A Drift: ≤6×10-13A/h Linearity range: ≥106   Thermal conductivity detector(TCD) Sensitivity:≥5000mV mL/mg (C16) Noise: ≤20µV Drif: ≤30µV/h Linearity rang: ≥104    High Sensitivity Thermal conductivity detector(HTCD) Sensitivity: ≥10000mV mL/mg (C16)    Electron capture detector(ECD) Detectability: ≤1×10-13g/s (γ-666) Linearity range: ≥103 Maximum using temperature: 350°C    Flame photometric detector(FPD) Detectability: ≤2×10-11g/s(P) (Parathion-methyl)                         ≤1×10-10g/s(S) (Parathion-methyl)    Nitrogen-phosphorus detector(NPD) Detectability: ≤5×10-12g/s(N) (Azobenzene)                        ≤5×10-13g/s(P) (Malathion)                         (On programmed)    Photoelectric ion detector(PID) Detectability: ≤1ppb           (Benzene)  

Optional Parts

Main function

SEGC1120-TCD

Thermal conductivity detector

SEGC1120-ECD

Electron capture detector

SEGC1120-FPD

Flame photometer detector

SEGC1120-NPD

Nitrogen phosphorous detector

Chromatographic work station

External interface box + work station (not include PC)

Simulation software

Imitation find chromatographic condition, emulation teaching, train and knowledge base.

                                gas chromatography,gas chromatography instrument,SOLVENT TEST Instrument technical index   Flexible Sample Introduction System Up to three injectors may be installed and operated simultaneously with independent temperature control. Wide range of injectors is available to be chosen from for various applications. It is very convenient for installation and disassembly of sample injectors. Sample Injector with Mono Packed Column/Double Packed Columns: Several alternative sample introduction methods, including on-column sample introduction and six-way valve injection; Adapter for injection to capillary column (0.53 mm i.d.). Sample injector for capillary column Special sample injector with septum purge and back-pressure valve splitting; Special programmable split/splitless injector with solenoid valve, septum purge, back-pressure valve splitting, and standalone carrier gas and make-up gas flow; Modified dual-packed-column sample injector for injection to capillary column by employing some connectors and back-pressure valve splitting.   Advanced Pneumatics Carrier gas control with constant pressure valve and constant flow valve; Air and hydrogen control with constant pressure valve and needle valve; Flow easily adjustable through constant flow valve and needle valve with digital display; High precision, reproducibility and reliability.   Sensitive and reliable detector Up to three detectors (FID, TCD, ECD, etc) may be installed and operated simultaneously. Simultaneous multi-detection with detectors in series or in parallel meets the various analysis requirements. The new FID provides higher sensitivity than ever before. It is very convenient to disassemble and clean the jet and collector. Precisely fixed emitter configuration ensures conformity of product performance; Excellent TCD detector with high-resistance tungsten-rhenium filaments provides high sensitivity. A sensitivity of 10000 mV·mL/mg is achieved with optional amplifier circuit board. Special configuration of air heat insulation enhances the stability of TCD detector Constant-current, pulse-modulated ECD detector sets sensitivity and current by computer.   Advanced Microcomputer Control System With advanced control techniques, microcomputer-based temperature control system provides superior performance. High temperature precision (± 0.5°C), high reliability, and high resistance to disturbance; Five independent heated zones, with maximum operating temperature of 400°C; Temperature-limit setting and overheat protection. Instrument control is accomplished through the keypad, and the instrument offers outstanding capabilities. Self-diagnosis; Power-off protection; Ten methods saving and reloading; Two controls of external events; Timing on/off of temperature control; Timing program, detector status, measurement range, polarity and current setting and display; Temperature setting values, actual values, retention time and analysis time display.   High-performance spacious column oven Spacious column oven accommodating capillary column and dual packed columns and convenient for column installation; Fast heat-up and rapid cool-down column oven with automated back-door opening (300°C to 50°C in 7 min); Available for both near-ambient and above ambient temperature control; Supports 5 oven ramps with 6 plateaus.  