Model No. : KNLE1-100
Brand Name : Korlen
Breaking Capacity : Low Voltage Circuit Breakers
Operation : Manual Type
Speed : Normal Type Circuit Breaker
Arc-extinguishing Medium : Air
Installation : Fixed
Structure : Elcb
Poles Number : 2
Type : Circuit Breaker
Function : Conventional Circuit Breaker
Certification : Ce
Rated Worling Current : 63;80;100a
Frame : 100a
Maximum Operating Time : I△n T≤0.1s , 5i△n T≤0.04
Sensibility : Ac Type
Rated Working Voltage : 240/415v
More
7yrs

Wenzhou, Zhejiang, China

Visit The Store
  • Platform Certification
  • Video

Product description

RCBO is the Residual Current Circuit Breaker with overcurrent protection. Basically, it performs the functions of MCB and RCCB together. This means that, it can be used to protect the line from being overloaded and short-circuited as well as infrequent changeover of the line in normal situation.


The series KNLE1-100 leak circuit breaker applies at the line of up to 230V for single phase or up to 400V for three phases with the rated current up to 63A to act as the leak protection. Where someone gets an electric shock or the leak current at the line exceeds the stipulated value, the circuit breaker could automatically break the power in 0.2S to protect the body and the equipment.
      The series KNLE1-100 leak circuit breaker performs the overload and short-circuit protection and also performs the low frequency of circuit switching under normal condition. This product conforms to the requirement of GB16917.1 standards.

Earth Leakage Circuit Breaker
Leakage Circuit Breaker
ELCB

Frame class 100A
Rated working voltage 240/415V
Rated frequency 50/60Hz
Rated working current 63,80,100A
Rated residual operating current 0.03,0.1A
Rated residual un-operating current 0.015,0.05A
Sensibility AC Type
Maximum operating time IΔn t≤0.1s , 5IΔn t≤0.04
Instant release type C type
Limiting value of un-operating current 6In
Rated limiting short-circuit current 6000A
Pole number 1P+N,2P,3P,3P+N
Mechanical life 8000
Electric life 4000


Sequence
NO .
Release Test
current I/In
Start state Tripping
time
Expected
restlt
1 c 1.13In Cold state t≤2h Not tripping
2 c 1.45In Start right after
the serial NO .
1 test
t<2h Tripping
3 c 2.55In Cold state 1s<t<120s Tripping
4 c 5In Cold state t≤0.1s Not tripping
5 c 10In Cold state t<0.1s Trippi