Product description
Features & Benefit
①Unique aluminum alloy with die-casting integrated technology, filter housing with 15 years warranty.
②Spin Element is compatible with lubrcants.Multi-wrap borosilicate fiber glass media, ensure filtration accuracy up to ISO8573.1-2010.
③100% leak-tested in three times
④Low pressure drop, saving energy and cost for ownership
⑤Manual Drain Valve
Element Specification
PF | AO | AA | AX | ACS | AR | AAR |
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible | High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21℃),1ppm(w). | High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21℃),0.01ppm(w) | Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21℃),0.001ppm(w) | Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21℃),0.003ppm(w) | Dust particles whose diameter more than 1μm can be removed | Dust particles whose diameter more than 0.01μm can be removed |
International test and measurement standard ISO12500
>ISO 12500 has made clear a general test and definition method for the compressed air filter manufacturers. The main performance
parameters are the air inlet oil content and particles size distribution of the solid particles.
>ISO12500-1 specifies the test requirements for the filtration performance of oil aerosol in the coalescing filter.
>ISO12500-2 specifies the test requirements of adsorption filters for the removal performance of steam adsorption.
>ISO12500-3 specifies the requirements for removal of particulate matter from solid pullutants.
Product are test with the international advanced testing equipment based on standard ISO12500, Which is equivalent to the standard ISO8573.1-2010 quality standard, and provide filter performance test report.
Filtration Grade | PF | AO | AA | AX | ACS | AR | AAR |
Size of solid particles(ISO12500-3) | 5μm | 1μm | 0.01μm | 0.01μm | - | 1μm | 0.01μm |
Filtration performance of solid particles(ISO12500-3) | - | 99.999+% | 99.999+% | 99.999+% | 99.999+% | 99.999+% | 99.999+% |
Filtration performance of oil(ISO12500-1) | 50% | 80+% | 99.9+% | 99.99+% | - | - | - |
Residual oil content(ISO12500-1) | 5mg/m³ | 0.6mg/m³ | <0.01mg/m³ | <0.001mg/m³ | <0.004mg/m³ | - | - |
Model
Pipe size
Flow rates
Dimension (mm)
L/S
m³/min
scfm
W (Width)
D (Depth)
H (Height)
A
B
C (clearance for housing)
YFB010
RC1/2"
16.7
1.0
35.5
96
79
252
29
223
118
YFB020
RC3/4"
25.0
1.5
53.0
96
79
252
29
223
118
YFB030
RC3/4"
30.0
1.8
63.6
96
79
286
29
257
153
YFB040
RC1"
33.3
2.0
71.0
96
79
286
29
257
153
YFB060
RC1"
60.0
3.6
127.0
138
111
357
37
320
208
YFB070
RC1"
83.3
5.0
177.0
138
111
458
37
421
303
YFB080
RC1-1/2"
125.0
7.5
265.0
138
111
458
37
421
303
YFB090
RC2"
166.7
10.0
353.1
174
142
558
58
500
467
YFB100
RC2-1/2"
216.7
13.0
459.0
174
142
558
58
500
467
YFB110
RC2"
283.3
17.0
600.0
174
142
838
58
780
794
YFB120
RC2-1/2"
316.7
19.0
671.0
174
142
838
58
780
794
YFB130
RC3"
416.7
25.0
883.0
220
184
645
74
571
514
YFB140
RC4"
466.7
28.0
989.0
220
184
645
74
571
514
YFB150
RC3"
683.3
41.0
1448.0
220
184
902
74
828
764
YFB160
RC4"
800.0
48.0
1695.0
220
184
902
74
828
764
Technical requirements
Maximum operating pressure: 16 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |