portable visual urine teststrip URS-5K ,urine dipstick test
portable visual urine teststrip URS-5K ,urine dipstick test
portable visual urine teststrip URS-5K ,urine dipstick test

1 / 1

portable visual urine teststrip URS-5K ,urine dipstick test

Get Latest Price
Send Inquiry
Model No. : URS-5K
Brand Name : WANCHENG

Product description

Specifications 1. urine dipstick test: urinalysis for diabetes

2. consumable urine dipstick test

3. high quality urine dipstick test

1. Urine dipstick test: urinalysis for diabetes
2. Consumable urine dipstick test
3. High quality urine dipstick test 4. Urine dipstick test OEM design welcome 5. Urine dipstick test fast delivery 
Remaining: 10638Remaining Photo(s): 1Add Navigations Product Description Packaging & Shipping Wancheng urinalysis strips are very resistant to interference from ascorbic acid (vitamin C). Some strips on the market are prone to vitamin C interference and give falsely-lower or false-negative results. The tests that are most affected are blood, glucose, bilirubin and nitrite.   1) Rapid Results   30 seconds to 2 minutes 3) High Quality      Color Chart Superior European-produced color charts provide consistent, dependable readings 4) Flexible             Available in up to 12 parameters 5) Cost Effective   25, 50, or 100 strips per bottle, with performance better than or equal to the current market leader at a much lower price Urine Reagent Strip (URS-5k)  OEM service could be offered     Testing Item: Glucose Ph Protein Ketone Blood   Dimension:   90(L)     5±0.2(W)   0.24-0.26(T)  (mm)               Glucose   This test is based on a sequential enzyme reaction. First, glucose oxidase catalyzes the formation of gluconic acid and hydrogen peroxide from the oxidation of glucose. A second enzyme, peroxidase, catalyzes the reaction of hydrogen peroxide with potassium iodide chromogen to oxidize the chromogen to colors ranging from blue through greenish-brown, and brown to dark-brown. Reactivity of the test decreases as the specific gravity and/or pH of urine increases, and may also vary with temperature. Ascorbic acid (more than 50 mg/dl) and ketone bodies (more than 40 mg/dl) may cause a false negative result for a specimen containing a small amount of glucose (100 mg/dl). However, the combinations of such ketone levels and low glucose levels are metabolically improbable.   pH This test is based on double indicators (methyl red and bromothymol blue), which give a broad range of colors covering the entire urinary pH range. Colors range from orange through greenish-yellow and green to blue. This test indicates the pH values within the range of 5 to 9. Certain drugs, such as those used for hypertension and heart diseases (acetazolamides) may cause an alkaline urine. Excessive urine on the test strip may wash the acid buffer from the neighboring protein reagent onto the pH area and change the pH reading to an acid pH although the urine being tested may originally have been neutral or alkaline. An accurate reading may be influenced by slight variations of pigments in the urine.     Protein This test is based on the color change of the indicator tetrabromophenol blue. A positive reaction is indicated by a color change from yellow through green and then to greenish-blue. The minimum sensitivity of this test is 10 mg/dl of protein in urine. Highly buffered alkaline urines (pH 8.5) may give false negative results. The interpretation of results is also difficult in turbid urine specimens.     Ketones This test is based on the reaction of acetoacetic acid in the urine with nitroprusside. The resulting color ranges from tan when no reaction takes place, to purple for a positive reaction. Normal urine specimens ordinarily yield negative results with this reagent. False positive results may occur with highly pigmented urine specimens or those containing large amounts of levodopa metabolites.   Blood This test is based on the pseudoperoxidase activity of hemoglobin which catalyzes the reaction of 3,3'5,5'-tetramethylbenzidine and buffered organic peroxide, 2,5-dimethylhexane-2,5-dihydroperoxide. The resulting color ranges from, greenish-yellow through bluish-green to dark blue. A false positive test result can sometimes occur when bacteria are present in the urine. Ascorbic acid or protein may reduce the reactivity of the blood test. Strong oxidizing substances such as hypochlorites may produce a false positive result. Urine from menstruating females often, but not always, yield positive results. This test is slightly more sensitive to free hemoglobin and myoglobin than to intact erythrocytes. The test is generally capable of detecting 0.015-mg/dl free hemoglobin or 5 to 10 intact red blood cells per ml of urine. The sensitivity may he reduced in urine with high specific gravity and ascorbic acid content. The appearance of green spots on the reagent test area indicates the presence of intact erythrocytes in the urine.       Visual Reading technique:                                                                                                      Step 1: Remove a test strip, taking care not to touch the reaction fields.                    Immediately close the container again.             This protects the remaining test strips from humidity and guarantees strip integrity up to the expiry date indicated.      Step 2: Dip the test strip for about 1 second into the fresh urine specimen. Wipe off any excess urine on the rim of the vessel and blot the edge of the test strip on tissue paper.     Step 3: Read the result by comparing the test fields with the color scale on the test pack after 30 to 60 seconds.                               Uncut Sheet 1-12 parameters are offered                     full automated production line, makes our product cheaper (price), faster (process time), better (quality).                  Other company                                                        Our company
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628