Specifications SV-YQ portable oxygen analyzer
1.Measurable emissions of petrol vehicles exhaust.
2.Components and oil smokeemitted.
SV-YQ portable oxygen analyzer Functional feature: Measurable emissions of petrol vehicles exhaust Components and oil smokeemitted by vehicles, no Other equipment, simple operation, powerful. Main technical feature: Measurement Range CO: 0-10% CO2 :0-20% HC: 0-10000ppm O2:0-25% NO:0-5000ppm N:O:-99.9% K:0-16.06m-1 Petrol temperature: 0°C-150°C Engine speed:0-20000rpm Zero point floating: CO: ±0.06% CO2: ±0.5% HC: ±30ppm O2: ±0.5% NO: ±30ppm N: ±2.0% Resolution: CO: 0.01% CO2:0.1% HC: 1ppm O2:0.01% NO:1ppm N:0.1% K:0.01m-1 Petrol temperature: 0.1°C Engine speed: 1rpm Indicated error: CO: ±5% CO2: ±5% HC: ±5%, O2: ±5% NO: ±5% N: ±2.0% Petrol temperature: Petrol temperature: ±2°C Engine speed: ±1% Display method: LCD large screen display Method of sampling: Double sampling probe, respectively for petrol and diesel exhaust emissions sampling Main functions: Built-in printer, RS232 interface,and meet the requirements, Setting plates, storage to 500 measurements. Weight :control unit: 6 kg Testing unit: 7.5kg Packing size :main machine : 620x495x325mm auxiliary machine :515X340x320mm