Partial Discharge Detector
Partial Discharge Detector
Partial Discharge Detector

1 / 1

Partial Discharge Detector

Get Latest Price
Send Inquiry
Model No. : XHJF801
Brand Name : X&H

Product description

  XHJF801 transformer partial discharge research and development of the intelligent monitoring device is our factory production of a new type of instrument. It basically keeps the original advantages of partial discharge detector and function, and committed to the instrument volume, weight, make it a truly portable instruments. The instrument is based on IEC standards (270), developed by pulse current method principle, and satisfy the DL/T846.4-2004, GB - 7354-2004, GB - 1207-2004, GB - 1208-97 of partial discharge test of test instruments specified technical requirements. The instrument has high sensitivity, large dynamic range amplifier system, the test sample (s) of a wide range, easy operation, etc. And adopts advanced anti-jamming components and unique door display circuit, strong anti-jamming capability, and has four kinds of high frequency elliptical scanning, suitable for high pressure type, factory test of products, new product development test, motor, transformer, cable, bushing, capacitors, transformers, switches and other quantitative test of high-voltage electrical appliances partial discharge. Technical data 1.Capacitance range of products can be tested:6pF~250uF 2. detection sensitivity (see Table 1). 3.The elliptical scanning time base (1) frequency:50,100,150,200,400Hz (2) rotation: 30 degrees as a file, can be rotated 120 degrees. (3) Work:Standard - Extended - straight line. (4) High frequency time base ellipse input voltage range:13~275V 4.Display unit:100 * 100 mm rectangle wave tube, the brightness and focus can be  adjusted 5.amplifier (1) 3 db low-frequency end frequency FL: 20, 40 KHZ optional. (2) 3 db high-frequency end frequency FH: 200, 300 KHZ, optional. (3) Gain control: 6 gears, gear 10 times gain difference between plus or minus 5%. (4) Fine tuning range: > 10 times. (5) The positive and negative pulse response asymmetry: < 5%. 6.Time-window (1) Window width: 5 degrees to 150 degrees (50Hz) continuous adjustable. (2) Window position: Each window can be rotated from zero to 170 degrees. (3) Two time windows can be controlled separately or simultaneously. 7.Impulse peak table (1) Linear instructions:0 ~ 100 error is not more than 5%. (2) the logarithmic instructions: 1 ~ 100 error is not more than 5%. (3) PC Table direct reading: 0 to 100 error is less than 5%. Diagram 1 Detection sensitivity and input unit allows current value (the system only selected input unit 2,3)  

SN

The capacitance range

Sensitivity(PC)

(unbalanced circuit)

Allow current RMS

Unbalanced circuit

Balanced Circuit

1

6-25-100pF

0.02

30mA

0.25A

2

25-100-400pF

0.04

60mA

0.5A

3

100-400-1500pF

0.06

120mA

1A

4

400-1500-6000pF

0.1

0.25A

2A

5

1500-6000-25000pF

0.2

0.5A

4A

6

0.006-0.025-0.1 uF

0.3

1A

8A

7

0.025-0.1-0.4 uF

0.5

2A

15A

8

0.1-0.4-1.5 uF

1

4A

30A

9

0.4-1.5-6.0 uF

1.5

8A

60A

10

1.5-6.0-25 uF

2.5

15A

120A

11

6.0-25-60 uF

5

25A

200A

12

25-60-250 uF

10

50A

300A

7R

resistance

0.5

2A

15A

8.Have aided identification of discharge pulse phase zero mark system. 9.Working power supply: AC 220 v + 10% power frequency 10.Size: 440 * 430 * 180 mm 11. weight:About 15 kg                                                                                                                   
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628