Open Type Engine Diesel Generator 45kva Model: GNRC45 Prime Power: 36KW/45KVA Standby Power: 40KW/50KVA Engine Model: 4BTA3.9-G2 Alternator Brand: Stamford or Marathon Alternator Model: UCI224D Frequency: 50Hz Voltage: 380/220V(Adjustable) Rated Currency: 65AMP
Generator Model | GNRC45 |
Standby Power(50Hz) | 50KVA/40KW |
Prime Power(50Hz) | 45KVA/36KW |
Voltage | 230/400 V |
Frequency | 50Hz |
Open generator Dimension | 1800*750*1450mm |
Open generator Weight | 930kg |
45kva generator Sales Promises l We provide a full line of brand new and high quality generator. Each generator is strictly factory tested. l Generator sale Warranty is according to : 12 months or 1000 running hours,subject to the earlier item |
45Kva generator set data |
Voltage Regulation: | ≥±5% |
Voltage Regulation, Stead State: | ≤±1% |
Sudden Voltage Warp (100% Sudden Reduce): | ≤+25% |
Sudden Voltage Warp (Sudden Increase): | ≤-20% |
Voltage Stable Time (100% Sudden Reduce): | ≤6S |
Voltage Stable Time (Sudden Increase) | ≤6S |
Frequency Reduce: | 0-5% adjustable |
Frequency Regulation, Stead State: | ≤1.5% |
Frequency Waving: | ≤0.8% |
Sudden Frequency Warp (100% Sudden Reduce): | ≤+12% |
Sudden Frequency Warp (Sudden Increase): | ≤-10% |
Frequency Recovery Time (100% Sudden Reduce): | ≤5S |
Frequency Recovery Time (Sudden Increase): | ≤5S |
Diesel Generator -Diesel Engine Data |
Manufacturer/Model | 4BTA3.9-G2,4-cycle |
Air intake system | Turbocharged,Water/Air DC |
Fuel system | AD model fuel pump |
Displacement | 3.9 L |
Cylinder arrangement | 4 in line |
Bore and Stroke | 102*120 mm |
Compression ratio | 16.5:1 |
Rated RPM | 1500rpm |
Max. Standby Power | 55KW/76HP |
Governor type | Electronic |
Exhaust gas flow | 14.8 m3/min |
Max intake Restriction | 6.2 KPA |
Fuel system 100%(Prime Power) Load | 14.5 L/h |
Total oil capacity | 16.4 L |
Oil Consumption | ≤4 g/kw.h |
Total Coolant Capacity | 24 L |
Controller ( Control panel ) Brand: Deep sea or Smartgen (Digital and intelligent) LED Screen and touch Buttons' Main Functions: 1- Display loading power, voltage, currencies, frequency, speed, temperatures, oil pressure, running time etc. 2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc. 3- Shut down when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc. Optional Accessories of 36kw Diesel Generator 1. ATS(Automatic Transfer Switch); Which can start the diesel generator when the main power is off; when the main power comes back, it will shut down generator. 2. MCCB (Molded case circuit breaker); It can protect the loading machine and the diesel generator. 3. Battery charger(float charger); When the generator hasn't been used for long time, the batteries will be no power, in that way, you can't start the generator. But the battery charger can charge the batteries from main power. 4. Extra daily fuel tank; It will be requested while the base fuel tank capacity is not enough for daily fuel consumption. 5. Paralleling system; This system can make several generators work together and automatically distrubute the load according to set. 6. Remote Control Panel: Which can control the generator by computer, if use a RS484 or RS232 digital cable to connect the generator to the computer 7. Water Separate(additional cooling system); If the ambient temperature is too high, it will be harmful to the diesel generator. Fan and water cooling is not enough for radiate. The water separate system is much better for cooling, and the life of generator will be much longer. 8. Spare Parts of Cummins engine; All the spare parts of each Cummins engine are supplied at very competitive price. Engine