N2XY CABLE 0.6/1KV XLPE INSULATED POWER CABLE LOW VOLTAGE LV XLPE CABLE
N2XY CABLE 0.6/1KV XLPE INSULATED POWER CABLE LOW VOLTAGE LV XLPE CABLE
N2XY CABLE 0.6/1KV XLPE INSULATED POWER CABLE LOW VOLTAGE LV XLPE CABLE

1 / 1

N2XY CABLE 0.6/1KV XLPE INSULATED POWER CABLE LOW VOLTAGE LV XLPE CABLE

Get Latest Price
Send Inquiry
Model No. : multicore cables
Brand Name : JYTOP

Product description

Specifications N2XY CABLE

XLPE CABLE is used for fixed installations such as electric power distribution networks or industrial installations

N2XY CABLE 0.6/1KV XLPE INSULATED POWER CABLE LOW VOLTAGE  LV XLPE CABLE   1KV XLPE INSULATED CABLE LV XLPE CABLE 0.6/1kV CU/XLPE/PVC(or PE) Power Cable 1. Description

Chinese Type

Description

Core qty

Conductors range

YJV

Copper conductor, XLPE insulation, PVC outer sheath Power Cable

1,  2,  3,  4, 3+1,

5,  4+1, 3+2

1.5~800mm2

YJY

Copper conductor, XLPE insulation, PE outer sheath Power Cable

1,  2,  3,  4, 3+1,

5,  4+1, 3+2

1.5~800mm2

ZA-YJV

ZB-YJV

ZC-YJV

Copper conductor, XLPE insulation flame-retardant Power Cable

1,  2,  3,  4, 3+1,

5,  4+1, 3+2

1.5~800mm2

WDZA-YJY

WDZB-YJY

WDZC-YJY

Copper conductor, XLPE insulation Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) flame-retardant Power Cable

1,  2,  3,  4, 3+1,

5,  4+1, 3+2

1.5~800mm2

NH-YJV

Copper conductor, XLPE insulation fire-resistant Power Cable

1,  2,  3,  4, 3+1,

5,  4+1, 3+2

1.5~800mm2

 2. Operating Characteristics Rated voltage: 0.6/1(1.2)kV
Max. permissible continuous operating temperature of conductor: 90 °C
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250 °C
The ambient temperature under installation should not be lower than: 0 °C
The bending radius of cable is recommended as following:
For single core cable: not less than 20 times of the diameter of cable
For multi-core cable: not less than 15 times of the diameter of cable 3. Application The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, in tunnel, in cable trench or in conduit, unable to bear external mechanical force. 4. Manufacturing Standards IEC 60502-1 & Chinese national standard GB/T 12706-2008                                                                                                           We can produce above cables according to popular international standards such as ASTM,BS,DIN,NF &AS/NZ also. 5. Main technical data   Main technical data of 0.6/1KV, Single core, Copper conductor, XLPE insulated and PVC or PE sheath cables    CABLE CONSTRUCTION: 0.6/1KV CU/XLPE/PVC or PE  

 

Cable size

 

Conductor type

Nominal thickness of XLPE insulation(mm)

Nominal thickness of PVC or PE sheath(mm)

Approx. cable overall diameter (mm)

Max. D.C resistance @ 200C  (Ω/km)

1x1.5mm2

RE or RM

0.7

1.4

5.6

12.1

1x2.5mm2

RE or RM

0.7

1.4

6.0

7.41

1x4mm2

RE or RM

0.7

1.4

6.5

4.61

1x6mm2

RE or RM

0.7

1.4

7.0

3.08

1x10mm2

RM

0.7

1.4

8.3

1.83

1x16mm2

RM

0.7

1.4

9.3

1.15

1x25mm2

RM

0.9

1.4

11.1

0.727

1x35mm2

RM

0.9

1.4

12.2

0.524

1x50mm2

RM

1.0

1.4

13.7

0.387

1x70mm2

RM

1.1

1.4

15.7

0.268

1x95mm2

RM

1.1

1.5

17.8

0.193

1x120mm2

RM

1.2

1.5

19.7

0.153

1x150mm2

RM

1.4

1.6

21.8

0.124

1x185mm2

RM

1.6

1.6

24.1

0.0991

1x240mm2

RM

1.7

1.7

27.1

0.0754

1x300mm2

RM

1.8

1.8

30.0

0.0601

1x400mm2

RM

2.0

1.9

33.5

0.0470

1x500mm2

RM

2.2

2.0

37.7

0.0366

1x630mm2

RM

2.4

2.2

39.9

0.0283

1x800mm2

RM

2.6

2.3

44.3

0.0221

  Note:  RE= round conductor   RM = stranded conductor    SM=sectional conductor        