Miraclink Holter ECG Cable
Miraclink Holter ECG Cable
Miraclink Holter ECG Cable

1 / 1

Miraclink Holter ECG Cable

Get Latest Price
Send Inquiry
Model No. : F1K7615A14
Brand Name :
10yrs

Langkou Community, Dalang Street Longhua New Zone, China

Visit The Store

Product description

Compatible with mortara

Our corporation is specialized in handling the business of sale SpO2 sensor, ECG cable etc. The company has cooperated with many clients both from domestic and overseas, and has obtained consistently high praise from our customers since it was set up.

The usage range
This specification suited for customer s appointed models.
Usage condition(GB9706.1-2007 10.2.1)
Rated temperature: 25
Operation environment: 10~40.
Storage and transport method: Individual moistureproof package for each
Product. Transport under the conditions of ambient temperature.
Construction

Appearance requests:
The cable is round and glossy. The color uniformity. The jacket is ok. No
Disrepair. No dirt. No disfigurement. Etc.
The surface of the connector is glossy. No burr. No obvious machine scar. No disfigurement. No modification. No dirt. No metal rust etc.
(EC13: 2002 4.1.1.5/IEC60601-2-47 6.1AA)Clear DOT-color and characters. The corresponding printing should be correct. (EC13: 2002 4.1.1.5/IEC60601-2-47 6.1AA)
Product labels for use in line with the requirements of EC53-1995 4.1
Product labels and graphics in line with the engraved die EN980-2008 / EU CE requirement
Product cleaning. Disinfection and chemical resistance in ine with the requirements of EC53-1995 4.3

Size requirements:
To check the Size according to the drawing which was issued by the
Engineer. (The important size requirements. Please notify it on time)

Packaging requirements:
The packaging in accordance with the requirements of the engineer
Drawing(Incase of special packaging requirements. Please promptly notify it. )
Technical requirements
ANSI/AAMI EC53: 1995/(R)2001
ECG executive standards: ANSI/AAMI EC53: 1995/(R)2001
Note: ANSI/AAMI EC53: 1995/(R)2001 Standard the not description
General requested by the executive.
Customer special electrical and mechanical performance requirements.
(Please check the Implementation standards in remarks. )

Electrical performance:
Conduction test: 100conduct ok. No short circuit. No open circuit.
No color difference.
(EC53: 1995 4.5.8&GB/T 5095.2-1997)conduct resistance: DC500V
≤ 2Ω . (EC53: 1995 4.5.8&GB/T 5095.2-1997)
1000V AC ≤ 0.25mA 1min.
High voltage test: Wire&wire. Wire&shield for 1000V AC ≤ 0.25mA 1min. Wire&outside for 5000V DC ≤ 0.25mA 1s(EC53: 1995 4.5.1)
Insulation test: DC500V ≥ 20MΩ . (GB/T 5095.2-1997 11.3)
Product design their own anti-EC53-1995 4.5.4 comply with the requirements.

Mechanical properties:
The connector&snap should be done with 90 angle swing test.
Main cable the swing test will weigh 500g. Swing angle± 90 degree.
30000 times. Height 300MM. (EC53-1995 4.5.5)
The trunk cable SR weight 15KG with 1 minute. (EC53-1995 4.5.6)
Plug life of products in line with the requirements of EC53-1995 4.5.7.
EIA364 reference design at the same time.
Connector to connect products in line with the impedance requirements of EC53-1995 4.5.8.
Products designed to connect retention EC53-1995 4.5.9 requirements.
Environmental Standard
All the raw materials should comply with RoHS standard
All of the processing of materials. Products must meet ISO 10993 standards.
The accessory
The proving documents of Samples Material.
Samples Test Report.
Send Inquiry