Specifications 1.support FF,PA,Hart protocal
2.0.075%high accuracy
3.4-20mA,digital signal multi output
4.measure gas,liquid and steam,etc
1. Profile NCS-PT105Ⅱ series Smart Pressure Transmitter with advanced, mature, reliable 3151
capacitance sensors has been designed meticulously by combining advanced
microprocessor technology and digital capacitance measurement technology.
The powerful functions and high-speed computing capability of the
microprocessor make it have excellent qualifications such as smart, high
precision, high reliability, stable zero and so on. Its LCD can display many physical
parameters (e.g. pressure, temperature, current and so on). It can realize the
functions such as zero adjustment, range settings by key-press operation, and
it is easy for field testing.
NCS-PT105Ⅱ series Smart Pressure Transmitter supports HART, FF, and PA protocol and
can measure pressure, differential pressure, liquid level, flow, and other
industrial parameters. It can be widely used in the petroleum, chemicals,
electricity, and metallurgical industries, etc. 2. Pictures
3. Parameters
Number |
Display |
Reason |
Methods |
1 |
Output current value is 0 |
a. power failure
b. wire cutting |
a. modify power
b. check wire |
2 |
HART smart transmitter output current value exceeds limit |
Failure connection between the
sensor and the circuit board. |
Check the connection. |
3 |
HART smart transmitter current fixed on
4mA,add pressure the output,no change. |
a. instrument in multi-point mode
b. leakage |
a. modify slaves address in single mode
b. check the connection of gas pipe |
4 |
Smart transmitter communication failure |
a. connection failure
b. multi-mode |
a. check the wire loop
b. check net |