1 / 1
Model No. : | Sun-902 |
---|---|
Brand Name : | sunbright |
Product description
1. Available all brand of the standards IV sets, the pump has 120 levels adjustment to keep high precision. |
2. Three levels occlusion pressure adjustment. |
3. The accurate ultrasonic bubble detector detects the bubble intelligent, safe and reliable. |
4. Double confirmation function when flow rate≥300ml/h, make safer and avoid misoperation. |
5. Anti-reverse function on motor to avoid upstream, make safer for patient during infusion. |
6. When the pipe broken, the medicine liquid will not into the pump. |
7. Adopts imported main spare parts: Japan Toshiba driver module, USA ATMEL and Japan NEC chip, good anti-interference function. |
8. Auto-lock control panel during infusion, to avoid misoperation. |
9. Able to set flow rate by single digit, tens digit and hundreds digit separately, not need to increase from single digit. |
10. The bright & large LED screen could be clear seen far from 10 meters. |
11. The transparent window in door could see infuse status. |
12. Real-time display infused volume. |
13. The light in the side of the door is convenient to operate in the night |
14. KVO (Keep Vein Open) function |
15. Bolus (Quick Infuse) function |
16. Purge (Evacuate Bubble) function |
17. Multi-alarm, make safer. |
18. Portable, light weight only 1.8KG. |
19. Easy to change the battery, only open the battery cover. |
20. Good circuit design, consumption≤10VA. |
21. Suit for large range voltage up and down. |
22. The chip in syringe pump is be processed by ourselves on SMT machine production line instead of by manual work, as weld every point by hand. |
Dimensions (mm) | 140(L)×150(W)×220(H) |
Weight | about 1.8kg |
Ambient temperature | +5℃~43℃ |
Relative humidity | ≤90%RH (Under without condensation status) |
Power supply | AC 90V~AC 242V, 50HZ |
Built-in battery | DC 12V 1800mAh rechargeable Ni-MH battery, the battery can be used continuously for 2 hours after full charged (24hours) under 25ml/h flow rate. |
Atmospheric pressure | 550hPa~1060hPa |
Storage temperature | -40℃~+55℃ |
Storage humidity | ≤95%RH |
Power consumption | ≤10VA |
Flow rate options | 1ml/h~1200ml/h, in 1ml/h increment |
Infusion total amount setting | 1ml~9999ml, in 1ml increment |
Occlusion pressure level | High: 825mmHg ± 150 mmHg (110kPa±20kPa) Middle:600mmHg ± 225mmHg (80kPa±30kPa) Low: 450mmHg ± 150 mmHg (60kPa±20kPa) |
Flow rate error | ±5% |
Alarm | occlusion, finish, low battery, standby (no operation), air in line, door open, motor troubles, AC power disconnected, starting up by battery |
Function | self-test, infusion amount setting, flow rate and infused volume display, power indication, safe flow rate limit, data preserves, KVO (Keep Vein Open) function |
Send your inquiry to this supplier