Medical Analyzer Apparatus medical Lab Analyzer MHS-88 Semi-auto chemistry analyzer
Specification:
Light Source | 6V/10W Halogen Lamp, Life span>3000 hours |
Standard filter | 340nm,405nm,546nm,578nm,670nm |
Linearity range | 0.000-3.000 Abs |
Cross contamination rate | ≤1% |
Test mode | Kinetics, Bichromatic, End-point , Fixed time , Differential , Multi-Standard |
Band width | ≤8nm |
Delay & Reading time | Programmable, 3~999 seconds |
Quality Control | QC results stored in memory , QC curve printable |
Display | Large LCD |
ABS volume | 200~2000ul |
Measuring | 32ul Flow cell or cuvette optional |
Temperature control | 25°C , 30°C , 37°C controlled by Peltier |
Printer | Built-in Thermal printer , RS232 |
Power supply | AC220V/110V |
Power consumption | ≤50VA |
Room temperature | 10°C~40°C |
Humidity | ≤85% |
Dimension | 490mmX388mmX206mm |
Weight | 9 KG |
MHS-200 Automated chemistry analyzer
Sample system :
Sample tray | 44 sample positions |
Sample volume | 3~30ul, programmed by 0.1ul step |
Sample probe | Liquid level detection and Collision protection automatically |
Probe cleaning | Automatic washing both inside and outside, Carry over<0.1% |
Sample dilution | Automatic |
Reagent system: Compartment 24h Cooling system maintaining temperature 4~15°C Pre-heating function inventory checking. Real-time monitoring of reagent volume and auto alarm
Reagent tray | 44 positions for single &dual Reagents |
Refrigeration | Refrigerated reagent |
Reagent bottle size | 20ml and 35ml |
Reagent volume | 150~300ul,programmed by 0.1ul step |
Reagent probe | Liquid level detection and collision protection automatically |
Probe cleaning | Automatic washing both inside and outside, Carry over<0.1% |
Reaction system : Reaction tray: 48 reaction cuvettes Reaction technology: Back-Dividing-Light technology Reaction volume: 200~300ul Reaction Temperature:37°C+0.1°C Mixing system: Independent mixing probe Optical system : Light source: Halogen-tungsten lamp Wavelength:340nm,405nm,450nm,494nm, 505nm,546nm,578nm,620nm,670nm,700nm Linear range:0~3ABS Control and Calibration system : Calibration mode: Linear(one point ,two point and multi-point),Logit-Log4P, Logit-Log 5P, spline, exponential ,polynomial, parabola Control rules: Westgard multi-rule Operation Unit Operation system: Windows2000 system or above Interface: RS-232 Working Conditions Power Supply: 220V+22V, 50/60HZ+1HZ Power consumption: ≤400VA Temperature:15~30°C Humidity: ≤85% Water consumption: 5L/h Dimension:760(L)X570(W)X1000MM Weight: approx.85kgs Reagent &Sample Plate
Reaction Plate:
MHS-400 Automated Chemistry Analyzer . Discrete , random access , fully automated
. 400 tests per hour ,up to 800 tests per hour with ISE
. 24-hour refrigeration for reagent tray
. Reusable cuvettes with auto-washing station
. Two independent mixing stirrers
. Clot detection and crash protection (vertical & horizontal)
. Built-in bar code scanner
. 115 sample position and 90 reagent position
. Bi-directional LIS interface