IST100 voltage stabilizer voltage regulator inverter
IST100 voltage stabilizer voltage regulator inverter
IST100 voltage stabilizer voltage regulator inverter

1 / 1

IST100 voltage stabilizer voltage regulator inverter

Get Latest Price
Send Inquiry
Model No. : IST00 voltage stabilizer voltage regulator inverter
Brand Name : ISTECH

Product description

  IST100 Series Low Voltage Variable-frequency Drive(VFD)  IST100 voltage stabilizer voltage regulator inverter Product Description   1.  Power range 0.37kw~800kw
 2.  Three way control method: No PG vector control, V/F control. Torque control
 3.  Start Torque, No PG vector control, 0.5hz/150%(SVG)
 4.  18.5KW~90KW inverter inside DC reactor, enhance input side power factor and enhance whole machine efficiency and stability.
 5.  1.5~15kw each specification built-in brake unit. Such as fast stop, can direct connects with brake resistance.
 6.  16 section easy PLC, Several section speed control and PID control
 7.  Support many types frequency set up, digital set up, analog set up, PID set up and communication set up ect.
 8.  Support start, stop DC brake.
 9.  Input and output terminal are all free program. User can combine many working model according to needs.
 10. Possess frequency jump control function. Avoid mechanical resonance to make system more reliable.
 11. Possess sudden electricity shut-off inverter no stop function     General Technical Specification of Inverter  

Item

Item Description

Input

Rated voltage: frequency

220V, 380V, 50Hz/60Hz

Allowed voltage working range

Voltage: 220V±15%,380V±15%

Voltage unbalance rate: <3%;

Frequency: ±5%

 

 

 

Output

Voltage Range

0-380V/460V

Frequency range

0Hz-650Hz

Overload capacity

General type(G type): 150%Rated current 1 minute; 200% Rated current 0.5s

Fan water pump Type(P type): 120% rated current 1 minute

    MainControlPerformance of inverter  

Modulation Way

Magnetic Flow Vector PMM Modulation

Speed adjustable range

1:100

Starting torque

When it is 0.5Hz, it is 180% Rated torque

Rotating speed of operation/Steady state precision

≤±0.5% rated Simultaneous rotating speed

 

Frequency Precision

Digital Setting: ±0.01%×highest frequency; simulation setting: ±0.2×highest frequency

Frequency Resolution Ratio

Digital setting: 0.01Hz; simulation setting: highest frequency ×0.1%

Torque improvement

Automatic torque improvement, manual torque improvement

0.1%~30%

V/F Curve

Four ways: one way: user sets V/F curve, three ways: lower torque characteristic curve( 2.0 power, 1.7 power, 1.2 power)

    Customer function

Fixed length control

When reaching set length, drive stops working.

Droop control

Suitable in many drives driving the same

load occasion

Tone adjusting

Adjusting tone of motor in operation

Instantaneous stop without stopping working

When instantaneous power down, through bus voltage control, ceaseless operation can be achieved.

Binding function

Run command channel and frequency given channel can be bound casually and switched over simultaneously.

  Operation function

Operation command channel

Given operation panel, given control terminal and given serial port can be switched off in many ways.

Frequency given channel

Number given, analogue voltage given, analogue current given, pulse given, serial port given, can be switched off in many ways.

Auxiliary frequency given

Realize flexible auxiliary frequency fine tuning, frequency synthesis

Pulse output terminal

0-50Hz pulse square wave signal output which can realize output of physical quantity of set frequency and output frequency.

Analogue output terminal 

2 ways analogue signal output, 0/4~20ma or 0/2~10V can be chosen respectively; the output of physical quantity such as setting frequency, output frequency can be realized.

  Main Control Performance

Speed adding and subtracting curve

Three ways: straight line speed adding and subtracting, S curve speed adding and subtracting and automatic speed adding and subtracting;

Four speed adding and subtracting time, time unit( minute/second) can be chosen, longest is 60 hours.

DC Braking

DC Braking Starting Frequnency: 0-60Hz;

Braking time: lower than 45 kW; 0.1-60.0 second;

Other: 0.0`30.0 Second

Braking current: general type( G type);0~100%;

Cooling fan pump type( P type): 0~80%

Inching

Inching frequency range: 0.10Hz~50.00Hz;

Inching speed adding and subtracting time: it can be set at 0.1s~60s, interval time between inching it can be set.

Multi-speed operation

Multi-speed can be realized through PLC installed internally or control terminal. 7 band of frequency can be set.

Internally installed PI

It can be easily formed into closed loop control system

Automatic energy-saving

operation

According to load situation, automatically optimize V/F curve and realize energy-saving of operation

Automatically

Voltage adjusting

When power grid voltage changes, it can  automatically keep output voltage stable

Automatic current limiting

Automatic limit for current during operation in order to prevent frequent over current and fault tripping

Automatic carrier wave adjusting

According to load characteristic, automatically adjust carrier wave frequency; selectable

  Pictures of voltage stabilizer voltage regulator inverter    
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628